background image

two, your exhaust fan is working only when it is required - saving power and wear & tear on 
your equipment.  At any time, if the humidity set point is exceeded the controller will activate 
the “Dehumidify Output” and reduce the humidity level under your preferred humidity setting.  
During the nighttime hours the controller turns the “CO² Output” off and activates the ‘Night 
Only Output’ outlet.  The ‘ Night Only Output’ may be used to run a circulation fan, garden 
maintenance night light or any other device that you would like only to run at night.  If during the 
nighttime hours the temperature exceeds the preferred setting, then the “ Exhaust Fan Output” 
is activated to lower the temperature to desired levels.  If the humidity set point is exceeded, 
then the “Dehumidify Output” is activated to lower the humidity to desired levels.  This provides 
the grower with 24 hour temperature and humidity control.  Controllers created for our industry, 
by our industry!

The Kronus 4 allows up to 15 amps of maximum capacity on a standard 120 Volt circuit.  The 
Kronus 4 is built with the highest quality components to provide the user with years of trouble 
free service.

Instructions for Operation

•  Securely mount your Kronus 4 in your grow area and away from any moisture, spray, 

pesticides, etc. 

• Plug your fan into the “Exhaust Fan Output’ outlet.
• Turn the fan ‘ON’ to the highest setting possible.
•  Plug your CO² Controller (Atlas 1) or a repeat cycle timer (Apollo 1) into the “CO² Output” 

outlet.

•  Then, plug your CO² Generator or CO² Regulator/Tank into the CO² controller or repeat cycle 

timer (See Installation Example section for more information)

• Plug your dehumidifier into the “Dehumidifier Output” outlet
•  Turn the dehumidifier ‘ON’ to the highest setting.  This allows the controller to maintain precise 

control of the humidity.

• Plug your circulation fan, night light, etc. into the “Night Only Output”.
•  Turn the circulation fan, night light, etc. ‘ON’ to the appropriate setting for your gardens 

requirements.

•  Set the ‘Temperature’ and ‘Humidity’ dials at the preferred temperature and humidity levels for 

your garden.

•  Place the remote sensor in the grow area up to 25 feet away from the Kronus 4 at plant 

canopy height. Make sure that the photocell on the sensor is not covered or shaded  and is 
receiving enough light to trigger the controller functions.

•  The photocell on the remote sensor ensures that  the  CO² generator or CO² tank only 

activates when your lights are on.  This is when your plants uptake CO².  To save your CO², 
the ‘CO² Output’ is automatically disabled when your ventilation equipment is active or in the 
nighttime hours.  The ‘CO² Output’ is active when the ‘CO² On’ LED is lit.

•  When the ‘CO² Output’ is disabled during daytime conditions because of excessive 

temperature,  the Kronus 4 begins a ten (10) minute delay process by polling the temperature 
level to confirm that ventilation is still required.  If confirmed after 10 minutes, then ventilation 
process begins and continues until the temperature level is lowered to below the dial setting.   
However, if the temperature drops to  within the dial setting during the ten (10) minute period, 
then the ‘CO² Output’ outlet is reactivated and resumes normal functioning.  

• Plug the Kronus 4 into a 120 Volt – 15 Amp outlet.
•  Use of a surge protection device is recommended to protect your Kronus 4 from  

potential damage.

•  Turn the Kronus 4 power switch to the ‘ON’ position.
• Your Kronus 4 will now control your equipment at the desired settings.

Warranty Information

•  Titan Controls warrants the original purchase of this product against defects in material and 

workmanship under normal use for three (3) years from the date of purchase.

•  During the warranty period, Titan Controls will, at our option, and without charge, repair or 

replace this product if the controller or any of its components fail or malfunction.

•  All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA) 

number prior to any service of the product.

•  This warranty is expressly in lieu of all other warranties, expressed or implied, including the 

warranties of merchantability and fitness for use and of all other obligations or liabilities on the 
part of the seller.

•  This warranty shall not apply to this product or any part thereof which had been damaged by 

accident, abuse, misuse, modification, negligence, alteration or misapplication.

•  Controllers with serial numbers or date tags that have been removed, altered or obliterated; 

broken seals or that show evidence of tampering; mismatched board serial numbers or 
nonconforming parts, are excluded from coverage.

•  Titan Controls makes no warranty whatsoever in respect to accessories or parts not supplied by 

Titan Controls.

• Monetary refunds of the warranty will not be given.

• The Buyer assumes all responsibility regarding the use & installation of this controller.

• All warranty service is provided through the factory or an authorized service representative.

•  This warranty shall apply only to the United States, including Alaska, Hawaii and territories of the 

United States.

• Defective controllers need to be returned with the “proof of purchase/receipt”.

•  For additional warranty information, contact a Titan Controls Technical Service Representative or 

your Dealer.

•  NOTE: Titan Controls is a manufacturer of environmental controls.  All sales offerings to the 

public are done through a nationwide group of Dealers.   No sales offerings will be made directly 
to the general public.

Service and Repair Program

•  For all service and repairs please contact one of our Technical Service Representatives for a 

Return Merchandise Authorization (RMA) number.

•  All factory service & repairs will be completed within 48 hours of receipt of controller and after 

authorization by customer for repairs.

 • Titan Controls will, at its discretion, repair or replace the controller.

•  Factory calibration services are available for all Titan Controls. Returning Units: Please contact 

your retail store for returns.