Troubleshooting Tips

If the Helios

®

 14 is not performing as expected, try the following:

a. Contact a certified Electrician to service your Helios

®

 14 lighting controller.

b. Check to see that your breaker has not tripped or been compromised. Replace breaker if 

necessary.

c. Confirm that your power input is active from your power panel and providing 240 Volts/150 

Amps/60 Hz to the controller.

d. Check the voltage input using a voltage test meter to verify power is flowing to the 

controller.

e. Make sure all of your connections are tight. Loose connections can cause “arcing”.

f.  After activating relay, confirm that power is active and proper at your 240 volt outlets. 

g. Verify that your power cords and ballasts are functioning properly and that there are no 

shorts or arcing occurring.

h. Should you find your circuit breaker keeps tripping, check your breakers to verify that they 

are the right amperage for your application.

i.  Still having problems with your Helios

®

 14? Please contact our Technical Service 

Representative at 888-808-4826 to assist you further.

Controller Specifications:

•  Size = 24”H x 28”W x 5.5”D

•  Weight = 40 lbs.

•  Input Amperage = 150 Amps

•  Output Amperage = 120 Amps

•  Voltage Input = 240 VAC 

•  Voltage Output = 240 VAC 

•  Relay Coil Voltage = 120 VAC

•  Timing Module Voltage = 120 VAC

•  24 Hour Mechanical Timer Voltage = 120 VAC

•  Maximum Wattage = 24,000 Watts (1000 watts per outlet)

•  Hertz = 60Hz

•  Electrical Relay Operations = 100,000 Cycles

•  RoHS compliant = Yes

•  Storage Temperature = 32°F (0°C) to 135°F (57°C) 

•  Operating Temperature = 40°F (5°C) to 125°F (52°C)

24 hour timer

to 150 AMP 

Po

w

er S

our

ce

Contr

olling a Light Bank

Installation Example