Titan Controls Atlas 5 Скачать руководство пользователя страница 6

 DATA HOLD
Press          to freeze the readings,
"HOLD” icon is displayed on the left 
top of LCD(Fig.6). All current readings 
are kept unchanged, except STEL and
TWA. Press          again to cancel the 
hold function. 

%

O

HOLD

CO

2

Fig.6

 BACKLIGHT
Hold down         for more than 1 second
to activate and cancel backlight function.

 MIN,MAX,STEL,TWA 
Under normal mode, press         to see 
the minimum, maximum, and weighted
average readings. Each press of         ,
it displays MIN, MAX, STEL, TWA in 
sequence and returns to normal mode. 

In MIN and MAX modes, it shows the  
minimum and maximum readings of 
CO on main display and of AIRor Dpor 

WB temperatures and humidity
on the lower displays. (Fig.7)

N
X

M  /AV

%

O

CO

2

Fig.7

In STEL and TWA modes, the main 
display shows the 

 

(STEL) and 8 hours(TWA). 

weighted average of 

CO

 

readings for the past 15 minutes

2

The lower 

displays are the current AIR, DP/WB
temperatures and humidity.  (Fig.8)

5

N
X

M  /AV

Содержание Atlas 5

Страница 1: ...Atlas 5TM Handheld Indoor Air Quality Monitor Instruction Manual Measures CO2 Temperature and Humidity...

Страница 2: ...ge Backlight for working in dark areas Audible CO warning alarm 2 Battery and adaptor power supply E manual on CO and 2 via RS232 interface 1 Thank you for purchasing this portable meter This device m...

Страница 3: ...olarity and good contact nd Lob will appear on the LCD And beeper sounds atter When an adaptor is used it will cut off the power supply from batteries The adaptor can t be used as a battery charger Wh...

Страница 4: ...ftm m s CO2 CO2 concentration in ppm Relative humidity in Air temp Dew point Wet bulb temp in o C or F o Symbols Turns on and off the meter Enters setup mode Sets as non sleep mode with SET CAL Esc DP...

Страница 5: ...Fig 4 Fig 5 TAKING MEASUREMENT Press to switch temperatures display The lower left display will cycle from air temperature dew point temp Fig 4 and wet bulb temp Fig 5 The meter starts measurement whe...

Страница 6: ...see the minimum maximum and weighted average readings Each press of it displays MIN MAX STEL TWA in sequence and returns to normal mode In MIN and MAX modes it shows the minimum and maximum readings...

Страница 7: ...Fig 9 The meter turns off automatically after 20 minutes of inactivity To override the function hold down and for 2 seconds to turn on the meter until n appears NOTE Auto sleep function will be disab...

Страница 8: ...ge is from 100 to 9900ppm When the preferred alarm value is set press to save the setting or without saving and return to P1 0 P3 0 TEMPERATURE SCALE Press or in P1 0 to access P3 0 for setting up tem...

Страница 9: ...be done in fresh outdoor air that is well ventilated Place the meter in the calibration site Turn on the meter and hold down and simultaneously to enter CO2 calibration mode Fig 14 400ppm and CAL are...

Страница 10: ...ter defaults to have the humidity calibrated with 33 and 75 salt solution The ambient condition is recommended o to be at 25 C 77o F and stable humidity better to be close to the calibrating value To...

Страница 11: ...ensor damaged 2 E02 The value is under range E03 The value is over range E04 The original data error results in this error DP WB E07 Too low voltage to measure CO 2 Replace batteries or use an adaptor...

Страница 12: ...ature Humidity Range 14 F 140 F 10 0 60 0 C Resolution 0 1 F 0 1 C Accuracy 0 9 F 0 6 C Range 0 0 99 9 Resolution 0 1 Accuracy 3 10 90 5 others Warm Up 30 seconds Operating 32 F 106 F 0 50 C 0 95 RH a...

Страница 13: ...Notes...

Страница 14: ...a period of one year from the date of purchase This warranty covers normal operation and does not cover misuse abuse alteration neglect improper maintenance or damage resulting from leaking batteries...

Страница 15: ...VANCOUVER WASHINGTON U S A www titancontrols net DISTRIBUTED BY...

Отзывы: