Titan Controls APOLLO 1 Скачать руководство пользователя страница 3

adjustment of the “Off time” ranges from three (3) minutes to eight (8) hours.

The switch is used to determine when the controller will be active.  The switch in the up 
position, configures the timer to be active during the “DAY” only.  If the switch is placed in the 
down position, the timer will be active during the “NIGHT” only.  The controller can also be 
configured to operate during “BOTH” the day and the night by placing the switch in the center 
position.  The controller will cycle the load output on and off in accordance with the preferred 
settings.   When the output is on, the “ACTIVE” LED will illuminate.  The Apollo 1 provides up to 
15 amps of capacity on a standard 120 volt circuit.  The Apollo 1 is built with the highest quality 
components and will provide the user with years of trouble free service.

Instructions for Operation

• Securely mount your Apollo 1 in your enclosure and away from any spray, water or mist.

• Set the “On time” to activate your equipment at preferred setting.

• Set the “Off time” to deactivate your equipment at preferred setting.

• Plug your equipment into the female side of the piggyback cord set.

• Turn on your equipment to desired setting.

•  Plug the male side of the piggyback cord set into a 120 volt/15 amp maximum branch circuit 

outlet.  Use of a surge protection power strip is recommended.

• Turn the power switch of the controller to the “ON” position.

•  Your Apollo 1 will now control your equipment at the desired settings until the power is defeated.  

•  To reset your Apollo 

 

1.    Simply turn “OFF” the switch, adjust your settings,  and turn “ON“  the power 

switch to activate controller at new settings.

Troubleshooting Tips

If the Apollo 1 is not performing as expected, try the following:

 

a.  Confirm that your power input is active and providing  

120 volts/15 amps to the controller.

 

b.  Check the voltage output of your piggyback cord set using a voltage test meter, 

fan or 120 volt light to verify power is flowing through controller.

 

c.  Make sure that your “DAY/BOTH/NIGHT” switch is in the correct  

mode for your application.

 

d.  If your Apollo 1 is not functioning in the correct mode, check the photocell to see if 

there is anything covering the photocell.  If so, clean the lens using warm water on 
a soft cloth.

 

e.  If timing is incorrect , try turning “On time” / “Off time” knobs slightly higher or lower 

to achieve correct timing pattern.  Once correct settings have been achieved, 
Apollo 1 will cycle at those settings until power is interrupted.

 

f.  If you are still having problems with your Apollo 1, please contact our Technical 

Service Representative to assist you further.

Warranty Information

•  Titan Controls warrants the original purchase of this product  against defects in material and 

workmanship under normal use for three (3) years from the date of purchase.

•  During the warranty period, Titan Controls will, at our option, and without charge, repair or 

replace this product if the controller or any of its components fail or malfunction.

•  All returns or repairs must be accompanied by a Return Merchandise Authorization (RMA) 

number prior to any service of the product.

•  This warranty is expressly in lieu of all other warranties, expressed or implied, including the 

warranties of merchantability and fitness for use and of all other obligations or liabilities on the 
part of the seller.

•  This warranty shall not apply to this product or any part thereof which had been damaged by 

accident, abuse, misuse, modification, negligence, alteration or misapplication.

•  Controllers with serial numbers or date tags that have been removed, altered or obliterated; 

broken seals or that show evidence of tampering; mismatched board serial numbers or 
nonconforming parts, are excluded from coverage.

•  Titan Controls makes no warranty whatsoever in respect to accessories or parts not  

supplied by Titan Controls.

• Monetary refunds of the warranty will not be given.

• The Buyer assumes all responsibility regarding the use & installation of this controller.

• All warranty service is provided through the factory or an authorized service representative.

•  This warranty shall apply only to the United Sates, including Alaska, Hawaii and territories of the 

United States.

• Defective controllers need to be returned with the “proof of purchase/receipt”.

•  For additional warranty information, contact a Titan Controls Technical Service  

Representative or your Dealer.

•  NOTE: Titan Controls is a manufacturer of environmental controls.  All sales offerings to the 

public are done through a nationwide group of Dealers.   No sales offerings will be made  
directly to the general public.

Service and Repair Program

•  For all service and repairs please contact one of our Technical Service Representatives for a 

Return Merchandise Authorization (RMA) number.

•  All factory service & repairs will be completed within 48 hours of receipt of controller and after 

authorization by customer for repairs.

 • Titan Controls will, at its discretion, repair or replace the controller.

•  Factory calibration services are available for all Titan Controls. Returning Units: Please contact 

your retail store for returns.  

Содержание APOLLO 1

Страница 1: ...es _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________ 1 Square 1 Foot ...

Страница 2: ... Dealer where you purchased it They will be able to further evaluate the unit and test its various components and quite possibly will be able to identify and or fix any problems If the Dealer is unable to fix the unit they will return it to us for factory repair If there are no Dealers in your area you may contact us directly for technical support If we cannot help you resolve the problem over the...

Страница 3: ...il power is interrupted f If you are still having problems with your Apollo 1 please contact our Technical Service Representative to assist you further Warranty Information Titan Controls warrants the original purchase of this product against defects in material and workmanship under normal use for three 3 years from the date of purchase During the warranty period Titan Controls will at our option...

Страница 4: ...minutes to 8 hours RoHS compliant Yes Cord set 6 feet 14 4 SWJ Storage Temperature 32 F 0 C to 135 F 58 C Operating Temperature 32 F 0 C to 120 F 50 C Installation Examples Controlling a CO2 Generator CO2 Generator Apollo 1 Apollo 1 Controlling a CO2 Tank with Generator Controlling a Water Pump Controlling a Fan CO2 Generator Apollo 1 Apollo 1 Tank with Pump Fan Apollo 1 Apollo 1 Tank with Pump Fa...

Отзывы: