Tisira TSH60X Скачать руководство пользователя страница 6

RECIRCULATING

DUCTED

WARNING // 

 DO NOT penetrate any screws 

into the range hood as this may result in 
electrical hazards.

WARNING //

 Failure to install the screws or 

fixing device in accordance with these 
instructions may result in electrical hazards.

DUCTED OPTION

1.  Remove the filter.
2.  Optional - Replace the 80mm front rail 

with the 40mm front rail. (inc in box)

3.   Make sure that internal switches are in 

ducted position. (see above)

4.   Determine the most efficient path for the 

ductwork, minimise bends and keep the 
length of the ductwork to a minimum.

5.   Before fixing the range hood, drill a hole 

to accommodate the 120mm ducting that 
you have selected.

6.   It is important to run and finish all 

ducting (install roof / wall caps) prior to 
installation of the hood.

7.   Ensure that access has been allowed for 

the power cable and plug.

8.   Hold the hood up to the underside of the 

cabinet. Screw the rangehood to the 
underside of the cabinet. Ensure that you 
do not damage any of the wiring during 
installation.

9.   Attach the ducting adaptor to the ducting.
10.  Re-install filter.
11.  Plug in the power to the unit, turn on and 

test.

RE-CIRCULATING OPTION

 

1.   Remove the filter.
2.   Remove the front cover to expose the 

front vents. Do not remove the top 
120mm outlet cover.

3.   Make sure that internal switches are in 

recirculating position. (see above)

4.   Drill 4 fixing holes as per the drawing. 

Ensure that access has been allowed for 
the power cable and plug.

5.   Hold the hood up to the underside of the 

cabinet. Screw the rangehood to the 
underside of the cabinet. Ensure that you 
do not damage any of the wiring during 
installation.

6.   Re-install filter.
7.   Plug in the power to the unit, turn on and 

test.

Note //

 When the rangehood is re-circulating, 

carbon filters should be installed. 