background image

10

INSTALLATION MANUAL

Model: VEN-3S-3R-HC, VEN-2S-2R-HC, VEN-1S-1R-HC

TIS CONTROL LIMITED

RM 1502-p9 Easey CommBldg

253-261 Hennessy Rd Wanchai

Hong Kong

TEXAS INTELLIGENT SYSTEM LLC

SUITE# 610. 860 NORTH DOROTHY DR 

RICHARDSON

TX 75081.USA

Copyright © 2020 TIS, All Rights Reserved

TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the 

United States of America. This company takes TIS Control Ltd. in other 

countries. All of the Specifications are subject to change without notice.

w w w . t i s c o n t r o l . c o m

TIS VENERA 1-3 GANG PANEL

PAIRING

 (MANUAL PROGRAMMING)

OTHER DEVICES THAT CAN CONTROL VENERA RELAYS 

2   

Go to any other wall panel and short 

press on any lighting button. 

3   

Test by pressing on the wall panel’s 

ON/OFF button. The Venera relay 

should respond by turning ON and OFF 

accordingly. 

To pair the TIS Venera AIR Switch with any TIS wall panel buttons, do the following:

CHANDELIER

00-00-00

IN 22

SPOTLIGHT

CEILING

WALL LIGHT

ROPE LIGHT

FLUORESCENT

CHANDELIER

00-00-00

IN 22

SPOTLIGHT

CEILING

WALL LIGHT

ROPE LIGHT

FLUORESCENT

1

Press on the button for which you want 

to program its relay on Venera for 12 

seconds  (for  example,  if  you  need  to 

program relay 2, then press button 

number 2) until you see the button LED 

start  blinking.

12”

Содержание VENERA VEN-1S-1R-HC

Страница 1: ... 3 refer to Model number Nominal voltage 110 230 V AC 50 60 Hz Nominal current per channel 8 A 230 VAC Output switching current Max switching current 10A 230 VAC Resistive 6A 230 VAC florescent Output service life 8A 230 VAC Output switching times 277VAC 30VDC Output service life Mechanical Endurance 10 000 000 OPS Output switching times Operating time 8mS at nomi Volt Releasing time 5 mS at nomi ...

Страница 2: ...ne Neutral and Load cables The installer should consider the total current consumption when selecting the wires Warranty There is a two year warranty provided by law The hologram warranty seal and product serial number are available on each device Read Instructions We recommend that you read this Instruction Manual before installation Safety instructions Electrical equipment should only be install...

Страница 3: ...s company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL INSTALLATION STEPS 2 Remove the switch cover Unscrew and pull the wall switch out Take the wires out of the load and line 3 There should be a total of 3 5 wires 3 wires if 1 gang 4 wires if 2 gangs 5 wires if 3 gangs Find the ne...

Страница 4: ...other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL INSTALLATION STEPS 4 Turn on the power at the main power breaker and carefully identify the live wire using a voltage tester 5 Turn off the power at the main power breaker again to turn off the voltage supply to the switch 6 Attach the neutral wire to the N termi...

Страница 5: ...ark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL INSTALLATION STEPS 7 Insert the Venera panel and the wires in the box and secure the panel using 2 screws 8 9 Install the Venera panel s top cover as shown i...

Страница 6: ...l of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL SERVER LINKING In order for a project to be fully linked to the TIS server server configuration must be enabled in just 1 product within that project If you have already done that with any other panel just ignore these steps and proceed to configuration steps To do the server link...

Страница 7: ...S Logo is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL SERVER LINKING 4 Select your server option and 4 digit password Then press Save 3 On the TIS app press Search and wait for a few...

Страница 8: ...C in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL 2 1 1 In the TIS App go to the settings and select TIS Air config and enter your SSID password 2 On the Venera panel press and hold the TIS logo for 6 seconds The logo will start blinking 6 C...

Страница 9: ... 2020 TIS All Rights Reserved TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL 2 2 1 1 4 Select the room and then select channel names and icons 5 Go to the configured room s ...

Страница 10: ...IS VENERA 1 3 GANG PANEL PAIRING MANUAL PROGRAMMING OTHER DEVICES THAT CAN CONTROL VENERA RELAYS 2 Go to any other wall panel and short press on any lighting button 3 Test by pressing on the wall panel s ON OFF button The Venera relay should respond by turning ON and OFF accordingly To pair the TIS Venera AIR Switch with any TIS wall panel buttons do the following CHANDELIER 00 00 00 IN 22 SPOTLIG...

Страница 11: ... notice w w w t i s c o n t r o l c o m TIS VENERA 1 3 GANG PANEL PAIRING MANUAL PROGRAMMING VENERA BUTTONS TO CONTROL OTHER DEVICES 2 Shortly press on any Venera switch button 3 Test the button on the panel by short pressing it for ON OFF and long pressing to dim Venera buttons can be programmed to control any other relay dimmer or plug in the same TIS network You can pair any light channels with...

Страница 12: ...RG button blinks purple color rapidly Reason The panel address conflicts with another device in the TIS network You need to press and hold the PRG button for 6 seconds so that the module can get a new address Device s PRG LED is RED Reason The device is not connected to Wi Fi Device can t link to Wi Fi router Reason 1 The device is too far from the Wi Fi router Reason 2 The SSID or password is not...