VENERA SINGLE CHANNEL DIMMER PANEL

Mounting Location

Install in a dry, well-ventilated location. 

Controllers may emit some mechanical 

noise.  Take this into account when deciding 

on a mounting location.

Data Cable

Use screened, stranded KNX cable and 

standard  RS485 data cable with four 

twisted pairs. Connect devices in a “Daisy 

Chain”.

Do not cut or terminate live data cables.

Warranty

We provide a warranty as required by law. 

A hologram warranty seal and product 

serial number are provided on each device.

Please send the description of the defect 

with Product S/N to our dealer network. 

Read Instructions

We recommend that you read this 

Instruction Manual before installation. 

 

 

Safety instructions

Electrical equipment should only be 

installed  and  fitted  by  electrically  skilled 

persons. 

Failure to observe the instructions may 

cause damage to the device and other 

hazards. 

These instructions are an integral part of 

the product and must remain with the end 

customer.

Programming

Advanced programming requires TIS 

Device Search software. Advanced 

software programming knowledge should 

be obtained in the advanced training 

courses.

Simple Installation

DIN Rail mount facilitates installation. 

Содержание KNX-PORT

Страница 1: ...nput EIB 12mA Power Consumption EIB 360mW Protection 2000V ESD Protection TIS Bus Number of devices on 1 line Max 64 Bus voltage 12 32 V DC Current consumption 50 mA 24 V DC Protection Reverse polarity protection Function programmable options TIS KNX Control lights ON OFF Dimmer and Shutter KNX TIS Control Lights ON OFF Dimmer Shutter Infrared and Air Condition Connection terminal KNX Bus Screw te...

Страница 2: ...e and standard RS485 data cable with four twisted pairs Connect devices in a Daisy Chain Do not cut or terminate live data cables Warranty We provide a warranty as required by law A hologram warranty seal and product serial number are provided on each device Please send the description of the defect with Product S N to our dealer network Read Instructions We recommend that you read this Instructio...

Страница 3: ...as Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m VENERA SINGLE CHANNEL DIMMER PANEL INSTALLATION STEPS 2 Mount the device on a DIN rail inside an approved enclosure 3 Connect KNX Cable to the red and black KNX terminal 1 Turn off TIS and KNX ...

Страница 4: ...l Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m VENERA SINGLE CHANNEL DIMMER PANEL INSTALLATION STEPS 4 Connect cat5e TIS network data cable to the TIS BUS port as per the connection diagram 5 Turn on TIS power supply and KNX Power supply The module s PRG green LED should start blinking GND white orange white brown D white gre...

Страница 5: ...is company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m VENERA SINGLE CHANNEL DIMMER PANEL TROUBLESHOOTING Device PRG LED is not Blinking Device not Powered Reason Device is not powered on no TIS BUS 24V nor KNX Power supply connected to the device Device PRG RED LED is blinking Reason Assigning the physical...

Отзывы: