LEADING EDGE DIMMER
INSTALLATION MANUAL
Model: DIM-4CH-3A
TIS CONTROL LIMITED
RM 1502-p9 Easey CommBldg
253-261 Hennessy Rd Wanchai
Hong Kong
TEXAS INTELLIGENT SYSTEM LLC
SUITE# 610. 860 NORTH DOROTHY DR
RICHARDSON
TX 75081.USA
Copyright © 2020 TIS, All Rights Reserved
TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the
United States of America. This company takes TIS Control Ltd. in other
countries. All of the Specifications are subject to change without notice.
w w w . t i s c o n t r o l . c o m
Turn off the main electrical source before
installation.
1
WARNING! HIGH VOLTAGE
Mount the device on DIN rails inside an
approved enclosure. The device can also
be installed using two mounting screw
holes.
2
+24
D+D-GND
+24
D+D-GND
Connect the RS485 data cable to the
TIS-BUS port following the product con-
nection diagrams.
It is necessary to loop the TIS-BUS cable
if the side bus-train terminal connects the
two DIN Rail modules.
3
DIM-4CH-3A
TIS-BUS
GND D-
D+ +24V
PRG
1
2
3
4
LOAD
2
3
4
1
N
L
N
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
To the TIS BUS Network
Cat5e
Connect the load (light channel) electrical
wires to outputs 1-4. The device is capa-
ble of managing up to 10 Amps, and each
channel dims up to 3A loads. The install-
er should make sure not to overload the
device and module channels.
4
1.5 mm Electric Cable
1.5 mm Electric Cable
GND(white-orange)&(white-brown)
D-(white-green)&(white-blue)
D+(blue-green)
+24V(brown-orange)
Cat5e connection
DIM-4CH-3A
TIS-BUS
GND D-
D+ +24V
PRG
1
2
3
4
LOAD
2
3
4
1
N
L
N
To the TIS BUS Network
Cat5e
INSTALLATION STEPS