background image

LEADING EDGE DIMMER

INSTALLATION MANUAL

This device is used to dim the brightness of com-

patible loads with the leading edge dimmer. It can 

also control scenes and sequences. It can be used 

for all dimmable lamps and transformers.

Automation Made Easy

Model: DIM-4CH-3A

6

58921

79602

3

BARCODE (UPC-A)

PRODUCT INFORMATION

PRODUCT SPECIFICATIONS

I/O Load Voltage

Number of channels

4

Nominal voltage

110/230 V AC 50/60 Hz 

Nominal current per channel

3 A

Maximum total channel load 

10 A

TIS Bus

Number of Devices on 1 Line

Max. 64

Bus Voltage

12-32 V DC

Current Consumption

<30 mA / 24 V DC

Protection

Reverse Polarity Protection

Protection

Over current 

4x internal Fuse aR class 6A

Over heat

Internal temp sensor protection

Over load

Dimmer coil max load up to 6A

Heat sink

Aluminum alloy with straight fin

Operating and display 

elements

Programming button (PRG)

For assignment of the physical address 

1-4 buttons

Manual ON/OFF and Programming

Functions 

Lighting Control Dimming

4 channels controlled separately 

Scenes

4 different scenarios

Sequences

4 different sequences

Dimensions

Width × Length × Height

145mm × 75mm × 91mm

Housing

Materials 

ABS anti fire 

Casing color 

Black Gray

Button color

Silver

IP rating

IP 20

Содержание DIM-4CH-3A

Страница 1: ...evices on 1 Line Max 64 Bus Voltage 12 32 V DC Current Consumption 30 mA 24 V DC Protection Reverse Polarity Protection Protection Over current 4x internal Fuse aR class 6A Over heat Internal temp sensor protection Over load Dimmer coil max load up to 6A Heat sink Aluminum alloy with straight fin Operating and display elements Programming button PRG For assignment of the physical address 1 4 butto...

Страница 2: ...der the total current consumption when selecting the wires Warranty There is a two year warranty provided by law The hologram warranty seal and product serial number are available on each device Read Instructions We recommend that you read this Instruction Manual before installation Safety instructions Electrical equipment should only be installed and fitted by electrically skilled persons Failure...

Страница 3: ...w holes 2 24D D GND 24D D GND Connect the RS485 data cable to the TIS BUS port following the product con nection diagrams It is necessary to loop the TIS BUS cable if the side bus train terminal connects the two DIN Rail modules 3 DIM 4CH 3A TIS BUS GND D D 24V PRG 1 2 3 4 LOAD 2 3 4 1 N L N GND white orange white brown D white green white blue D blue green 24V brown orange Cat5e connection To the...

Страница 4: ...h cables respectively The device input must have an appropriate MCB to protect that load circuit 5 Turn on the power source and then test the loads by short pressing on local over ride buttons 1 4 on the device 6 O OFF I ON MCB Connect To L Connect To Earth Connect To N 1 5 mm Electric Cable 1 5 mm Electric Cable 2 5 mm Electric Cable GND white orange white brown D white green white blue D blue gr...

Страница 5: ...ss the light icons on any wall panel such as Luna Mars Terre etc 2 TER 4G 45mm D 24V GND D 45mm 221 227A 12EM4 227A 12EM4 TER 4G A 45mm 45mm ADD 3R 5A ADD 3R 5A 50mm 54mm PANEL ADDITION 3 Output Relay 5 Amp Model ADD 3R 5A TIS BUS Input 45 75mA 24V DC Output Current 3A220VAC COM OUT3 OUT2 OUT1 COM www tissmarthome com D 24V GND D Press on any buttons 1 4 for 6 seconds so that the LED indicator of ...

Страница 6: ... There is no power or no connection to the L N input Reason 2 The TIS 24V power supply is not connect ed to the TIS BUS The LED is ON but the lights are OFF Reason 1 The lights neutral wire is not connected Reason 2 There is no 110V 220V output from the dimmer Change the fuse of the burned channel inside the dimmer The load lights flicker Reason Lights are not compatible with the dimmer Use compat...

Отзывы: