The remote control and automation interface provides the following functions:
Mode
Name
Rx Comment
0
Internal
open everything internally
1
Pulse 1
1k 1% I1, I2 internal; t1, t2 external
2
Pulse 2
4k 1% I1, I2 external; t1, t2 external
3
Footmode
10k 1% I1 external % from I1 internal
4
Remote 1
22k 1% I1, I2 external
5
Remote 2
47k 1% I1 external
6
Remote 3
100k 1% I1, I2 external; Upslope, Downslope external
7
Spottime
150k 1% Spottime external
8
Upslope external
220k 1% Upslope external
9
Pulse 1 +
Footmode
470k 1% I1, I2 internal; t1, t2 external
I1 external % from I1 internal
Mode 1 – Internal Pulsing
The current setting I1 and I2 takes place on the control panel.
The pulse times t1 and t2 can be set externally.
Mode 2 – External Pulsing
The current settings I1 and I2 as well as the pulse times t1 and t2 can be set externally.
Mode 3 – Limitation of welding current
In this mode, generally only 2-Stroke operation is selected.
Externally, the current setpoint can be varied between the minimum and the internal current
setpoint I1.
Mode 4 – Mode 6
In these operating modes, an externally connected potentiometer assumes the function of the
internal I1 setpoint specification on the control panel.
Mode 7 – Spottime function
In the operating mode Spottime, the spot time can be set with an externally connected
potentiometer