2. TIOKRAFT VL20 OVERVIEW

The

TIOKRAFT VL20

air cleaner- disinfectant is intended for purification of indoor air, including

reduction of viral, microbial and other micro particulate contamination exceeding 10nm (0.01

microns), where such purification must be carried out during human presence.

The air purifier

TIOKRAFT VL20

is designed for efficient molecular purification of air from

miniscule organic pollutants, bacteria, viruses, fungi and mold spores in poorly ventilated

rooms. Purification of air from organic impurities (including pathogenic microflora) occurs

through their oxidation on the filtering element, as a result of which such impurities are

completely decomposed into trace amounts of water vapor and carbon dioxide.

The

TIOKRAFT VL20

air purifier is recommended for purification of indoor air from all organic

microparticles in areas requiring surgical-grade air purity

including households with people

suffering from allergies (spores and pollen), library archives (mold and fungus), public places

such as fitness clubs, restaurants, hotel and office lobbies (bacteria and viruses) and just about

any work place where air quality is strictly regulated.

Fig.1 TIOKRAFT VL20 
overview

3

VL20

Содержание VL20

Страница 1: ...VL 20 Krasnoye Pole LLC Version 1 2 June 2020 TIOKRAFT VL20 User Manual PHOTOCATALYTIC AIR CLEANER DISINFECTANT VL20...

Страница 2: ...emely dusty environments use in conjunction with a third party air filtering appliance Dear customer Thank you for purchasing the TIOKRAFT VL20 an advanced air purification device designed to silently...

Страница 3: ...ventilated rooms Purification of air from organic impurities including pathogenic microflora occurs through their oxidation on the filtering element as a result of which such impurities are completely...

Страница 4: ...PRECAUTIONARY MEASURES Use the product indoors only Device vents must remain unobstructed at all times Do not operate the device near a shower bath washbasin or in places where steam may accumulate E...

Страница 5: ...ice losing its effectiveness as well as loss of warranty 8 PRINCIPLE OF OPERATION Operation of the device is based on photocatalytic oxidation of organic impurities on a porous glass surface nanocoate...

Страница 6: ...t is recommended to keep the device on continuously Top vent Bottom vent ON OFF switch Fig 3 Device vents and power switch 9 OPERATION Prior to switching on the device for the first time ensure that i...

Страница 7: ...ction A and remove it by gently pulling in direction B up 3 Flip the bottom cover 180 degrees and place it side by side providing access to the UV lamps 4 Unclip the upper end of the UV lamps and remo...

Страница 8: ...nts of SanPiN 2 1 7 2790 10 Sanitary and epidemiological requirements for the management of medical waste Class A or similar 14 WARRANTY This product has been designed manufactured tested and packaged...

Страница 9: ...ried out by a qualified technician Unauthorized tampering with the device will void its warranty and may lead to damage to the device 16 CONTACT INFORMATION Krasnoye Pole LLC Moscow region Krasnoarmey...

Страница 10: ...L20 BASED ON ACTUAL MICROBIOLOGICAL STUDIES NOTE CFUs in the following diagrams represent Colony Forming Units which are a unit used in microbiology to estimate the number of viable able to multiply b...

Страница 11: ...snoye Pole LLC 2020 11 APPENDIX 1 SUGGESTIONS ON PLACING YOUR TIOKRAFT VL20 BASED ON ACTUAL MICROBIOLOGICAL STUDIES CONTINUED Case Study 2 Clinical Lab 16 sq m Test conditions windows and door closed...

Страница 12: ...12 APPENDIX 1 SUGGESTIONS ON PLACING YOUR TIOKRAFT VL20 BASED ON ACTUAL MICROBIOLOGICAL STUDIES CONTINUED Case Study 3 Bedroom 20 sq m Test conditions window closed door open at all times BEFORE AFTER...

Отзывы: