10
IP Power Socket 5G10A v2 – LANLIS-002
www.tinycontrol.eu
Reading XML data
Enter the IP address and the page name eg 192.168.1.100/st0.xml
The values of the sensors should be divided by 10
Control Panel:
- Dynamic data - st0.xml
- Static data - st2.xml
Events Config:
s.xml
Watchdog:
w.xml
Scheduler:
sch.xml
Network Config:
board.xml
Working time:
s_time.xml using the Timezone
Switching sockets http request
You can arm / switch set out without clicking on the buttons in the control panel, making
use of the following commands:
IP / outs.cgi ? out = xxxxx
- switches set the output to the opposite of the current
IP / outs.cgi ? outx = x
- disable or enable a specific output
when password authentication is enabled , the command of the following form:
user : password @ IP / outs.cgi ? out = xxxxx
user : password @ IP / outs.cgi ? outx = x
Examples:
192.168.1.100/outs.cgi ? out = 0
- changes the output state to the opposite out0
192.168.1.100/outs.cgi ? out = 2
- out2 output changes state to the opposite
192.168.1.100/outs.cgi ? out = 02
- changes the output state out0 and out2
to the opposite
192.168.1.100/outs.cgi ? out = 01234
- changes the state of the outputs of out0 to out4
the opposite
192.168.1.100/outs.cgi ? out0 = 0
- turns out out0 ( ON state )
192.168.1.100/outs.cgi ? out0 = 1
- turns out out0 ( OFF )
192.168.1.100/outs.cgi ? out1 = 0
- turns out out1 ( ON state )
192.168.1.100/outs.cgi ? out1 = 1
- turns out out1 ( OFF )
192.168.1.100/outs.cgi ? out4 = 0
- turns out out4 ( ON state )
192.168.1.100/outs.cgi ? out4 = 1
- turns out out4 ( OFF )