TROUBLESHOOTING
ISSUE
ASSUMPTION
SUGGESTION
NO LED
battery not present, or too low
of voltage to power instrument
Replace 9v battery
NO ALARM ON VISUAL
HOLIDAY IN COATING
Ground connection issue.
Check ground connection to
substrate
NO ALARM ON VISUAL
HOLIDAY IN COATING
Ground connection has too
much resistance in the circuit
Move/change the ground
connection point to the
structure.
NO ALARM ON TOUCHING
BARE GROUND CABLE
Ground cable not connected
properly to instrument.
Remove and reconnect
ground cable.
NO ALARM ON TOUCHING
BARE GROUND CABLE
Wand not properly connected
to instrument.
Remove and reconnect wand,
ensuring the wand has been
screwed down all the way into
instrument.
NO ALARM ON TOUCHING
BARE GROUND CABLE
Sponge not wet or conductive. Rewet the sponge or check
the sponge connection to the
wand.
FACTORY REPAIRS
Holiday Detectors returned to the factory for repairs should be sent TRANSPORTATION PREPAID. In
most cases the detector can be repaired and returned the same day it is received at the factory.
WHEN ORDERING PARTS FOR YOUR DETECTOR OR REQUESTING FURTHER INFORMATION
ALWAYS GIVE THE DETECTOR’S SERIAL NUMBER.