Timpex ECO 10+ Скачать руководство пользователя страница 15

 
ECO 10+ Automatic Regulation of Burning 

14 

9

 

COMMON ERRORS AND SOLUTIONS 

App background is red during whole burn cycle

 

 

Most likely bad wiring on the thermal sensor. Make sure that wires to the sensor are 
correctly and tightly plugged in, and check that the sensing tip and the wiring of the 
sensor itself are undamaged. 

App background remains only yellow or grey throughout the burn cycle 

 

Your firebox may not be capable of reaching the temperature preset as optimal for the 
selected program. Go to the mobile app and switch to a cooler (lower-numbered) 
program. 

The EAI shutter keeps opening to 100% (full open) 

Caused by the SDS or physical door sensor, if present. 

 

If using SDS, go to the mobile 

app’s Settings and lower SDS sensitivity.

 

 

If using the Magnetic Door Sensor (with SDS turned off), check that the gap between the 
main body of the sensor and the magnet is not greater than the recommended maximum 
of 10 mm. 

The app rejects the PIN 

 

The correct PIN is always 

123456

. Some mobile phone manufacturers choose to display 

“helpful” suggestions of other “commonly used” default PINs. These are, in this case, 

incorrect and should be ignored. 

The app fails to connect to the control unit 

 

First, make sure 

that your device meets the app’s software requirements.

 

 

Second, verify that no other mobile device is currently paired to the control unit. The 
control unit is only capable of being paired with one device at a time. 

The app displays “MAN” on the main scree

n and automatic regulation is not working  

 

Automatic regulation is turned off in the app Settings. Turn it on in menu. 

Current exhaust temperature readout shows “

- - -

 

 

The exhaust temperature readout only shows when flue gas is warmer than the 

environment. Temperatures below 25 Celsius are not shown; the “

- - -

“ symbol displays 

instead. 

 

If “

- - -

“ continues to show even when the firebox is hot, check the thermal sensor f

or bad 

wiring and / or damage. 

The app background is grey (cold firebox), but the EAI shutter is 100% open  

 

There may have been a malfunction on the thermal sensor during the last burn cycle. In 
this case, the control unit reacts by opening the shutter to 100%, for safety reasons. 

 

Try press START button. If the sensor problem has resolved itself, a new burn cycle should 
continue normally without the need for you to do anything. If it does not, check the 
thermal sensor for bad wiring and / or damage. 

 

Содержание ECO 10+

Страница 1: ...USER MANUAL Automatic Regulation of burning for fireplace stoves ECO 10...

Страница 2: ...n obrazovka Chyba Z lo ka nen definov na 4 2 Menu 8 5 CONTROL UNIT SOUND ALERTS 11 6 USING AUTOMATIC REGULATION OF BURNING 11 6 1 Start 11 6 2 Refueling 11 7 SAFETY INSTRUCTIONS 12 7 1 What to Do in C...

Страница 3: ...g The mobile app informs the user about the current status throughout the entire burn process Based on the current firebox temperature the app displays 3 color indicators yellow green red The user sho...

Страница 4: ...rning has a microprocessor based control unit which compares the current situation in the firebox with a Combustion Optimization program depending on the results the system adjusts the airflow to the...

Страница 5: ...ailable on Google Play under the name Timpex ECO QR Code for download 2 2 Apple iOS Devices Apple iOS 11 or newer Bluetooth LE GPS module The app is available on the App Store under the name Timpex EC...

Страница 6: ...arches for your specific ECO 10 control unit only near your position 4 Once launched the app starts an automatic search for nearby ECO 10 devices Once the search completes the app will show a list of...

Страница 7: ...n current firebox temperature yellow firebox temperature below optimum should only show when starting a fire or when down to hot coals green firebox at optimum temperature best fuel efficiency shows a...

Страница 8: ...Menu below Burning phase circle Maximum burn point A Refueling point with sound alert B START button Press to start a new automatic burn control cycle Details see Start Burn Control below SDS activity...

Страница 9: ...is inactive The EAI shutter can then be moved manually using its attached handle or the stove s own shutter handle can be used When automatic control is off the Main Screen shows MAN for manual mode...

Страница 10: ...rature to shutter position in a different way The factory setting is no 3 which should work well with most fireboxes If your firebox generally burns too hot using program 3 step down to program 2 or f...

Страница 11: ...closed for entire duration of active burn control incl hot coals phase o Refuel signal relay contacts close for 1 minute when a refueling request is fired o Exhaust fan relay contacts close upon recei...

Страница 12: ...ping the speaker icon in the mobile app main screen 6 USING AUTOMATIC REGULATION OF BURNING 6 1 Start Starting burn control launches a new controlled burn process At start the EAI shutter opens fully...

Страница 13: ...osition it was in before power failed If you subsequently need to refuel it is essential to manually open the air intake shutter to the 100 position If your heating system includes a water heat exchan...

Страница 14: ...rature has been reached automatic regulation of burning starts The program ensures optimal combustion and maximizes heating efficiency Once the firebox reaches maximum temperature the app background s...

Страница 15: ...fault PINs These are in this case incorrect and should be ignored The app fails to connect to the control unit First make sure that your device meets the app s software requirements Second verify that...

Страница 16: ...of the problem 11 TECHNICAL DATA Control unit input power 5V DC 50Hz 0 3A Control unit heat resistance max 50 C Temperature sensor heat resistance iron part max 700 C Disposal method dispose of as se...

Страница 17: ...INPUT 0 3 A OUTPUT SERVO 5V DC INGRESS PROTECTION IP40 Made in Czech Republic THANK YOU FOR USING OUR PRODUCT Thank you for purchasing our product the ECO 10 Automatic Regulation of Burning for firep...

Отзывы: