Timpdon Marine MRSS4 Скачать руководство пользователя страница 6

Timpdon Marine

 

Tel    0161 - 980 8054 

Issue 1 – June 2011 

 

Web

 

www.timpdon.co.uk 

 

EMail  [email protected]  

 

When satisfied, press and hold both switches 

S1

 and 

S2

 together. 

 

The 

LED

 will flash rapidly for about 2 seconds, and then go on 

continuously.  Then release both switches. 

 

If you release either switch before the LED stops flashing, the unit 

will remain in program Step 3. 

 

 

The unit will then save all programmed values to non-volatile memory. 

 
 

The 

LED

 will then flash rapidly for about 4 seconds to indicate completion 

of programming, and then the 

MRSS4

 will automatically reboot in normal 

operation mode, with the new programmed settings operational. 

 
 

The 

MRSS4

 is now ready for use. 

 

 

 

Notes on Programming 

 

 

Once you have entered programming mode, there is no exit until all 
programming steps have been completed. If you enter programming mode 

inadvertently, and you do not wish to re -program the unit, remove and re -
apply power, to restart in normal operation mode. 

 

Remember that no new programmed settings are saved until the end of 
programming 

Step 3

. All steps must therefore be completed for 

programming to be valid. 

 

If you make an error during programming, simply repeat the programming 
procedure after the unit has re -booted in normal operation mode. 

Отзывы: