Timotion TBB7 Скачать руководство пользователя страница 10

 

TBB7  User  Manual 

 

 

Version C July 2017 

10 

 

8.2

 

Cycle test curve 

Sample 

12V battery cell 

Steps 

1-49

th

 times 

5.0Ah 

2.9Ah 

Cycle 

300 times (memo each 50

th

 times) 

Discharge for 2hrs 

1250mA 

720mA 

X axis 

Cycle (times) 

Charge for 6hrs 

500mA 

290mA 

Y axis 

Max capacity (Ah) 

50

th

 times 

5.0Ah 

2.9Ah 

Remark 

In real situation the discharge/ 
charge varies- this test is only for 
reference 

Discharge until protect 

1250mA 

720mA 

Charge until max capacity  500mA 

290mA 

*Repeat since 51

th 

times 

 

1

50

100

150

200

250

300

Max capacity (Ah)

4.8

4.5

4.0

3.6

2.8

2.5

2.1

0

1

2

3

4

5

6

TBB6 and TBB7 (5.0Ah) cycle test curve 

1

50

100

150

200

250

300

Max capacity (Ah)

2.9

2.7

2.4

2.2

1.8

1.6

1.4

0

0.5

1

1.5

2

2.5

3

3.5

TBB6 and TBB7 (2.9Ah) cycle tst curve 

Содержание TBB7

Страница 1: ...VERSION C 20170717 TBB7 User Manual...

Страница 2: ...ifications 4 3 Operation 6 4 Indications 6 4 1 Status 6 4 2 Table 6 4 3 Table TP7C 6 4 4 Remarks 6 5 Installation 7 6 Protections 8 7 Maintenance 8 7 1 Storage 1 8 7 2 Transportation 8 7 3 Storage 2 8...

Страница 3: ...17 3 1 Warning Must follow the rated input voltage Don t discard or expose the products into water or heat source Recycle with certified depots Repair by authorized maintenance centers With certified...

Страница 4: ...1C discharge 500mA 2 9Ah 0 1C discharge 290mA Input 29 45V DC Output 24V DC 5 0A 24VDC 2 9A Duty cycle 10 2 min on 18 min off Operation temperature 5 45 IP rating Up to IP66W Dimension 345 100 114 mm...

Страница 5: ...TBB7 User Manual Version C July 2017 5 2 9Ah...

Страница 6: ...range Long dimming 0 5 sec 4 sec Protection 20 Off Failure Orange Continuous on 4 3 Table TP7C When charge by TP7C TBB7 LED become off and the status only shown on TP7C Status Capacity LED Hi charging...

Страница 7: ...TBB7 User Manual Version C July 2017 7 5 Installation...

Страница 8: ...ore long period storage without AC in First operation after long period storage 7 1 Storage 1 Storage period when without AC in V S estimated capacity 100 capacity when shipped out from factory Period...

Страница 9: ...axis Discharge current A Y axis Discharge time min Remark In real situation the discharge varies this test is only for reference 1A 2A 3A 4A 5A 6A Time min 230 108 69 48 39 30 0 50 100 150 200 250 TBB...

Страница 10: ...50th times 5 0Ah 2 9Ah Remark In real situation the discharge charge varies this test is only for reference Discharge until protect 1250mA 720mA Charge until max capacity 500mA 290mA Repeat since 51th...

Отзывы: