Device Wiring (Without Secure Door Control Unit)

Notes: 

    When connecting door magnetic sensor and exit button, the device and the 

    RS-485 card reader should use the common ground connection.

    The Wiegand terminal here is a Wiegand input terminal. You should set 

    the face recognition terminal’s Wiegand direction to “Input”. If you should connect 

    to an access controller, you should set the Wiegand direction to “Output”. For details, 

    see Setting Wiegand Parameters in Communication Settings in the user manual.

2

2.1

Network Interface

Installation Environment: 

Indoor and outdoor installation are supported. If installing the device 

indoors, the device should be at least 2 meters away from the light, and 

at least 3 meters away from the window or the door. If installing the 

device outdoors, you should apply Sililcone sealant among the cable 

wiring area to keep the raindrop from entering.

Make sure the environment illumination is more than 100 Lux.

Direct Sunlight

Direct Sunlight

through Window

Indirect Sunlight

through Window

Dimensions:

Backlight

Note:

 

The figures are for reference only.

10Lux

>1200Lux

100~850Lux

1
2

3

Notes:

     The installation height here is the recommended height. You can change it according 

     to your actual needs.

     You can also install the device on the wall or other places without the gang box. For 

     details, refer to the User Manual.

     For easy installation, drill holes on mounting surface according to the supplied 

     mounting template.

Drill holes on the wall or other surface according to the mounting template and install the gang box.

Use two supplied screws (4_KA4×22-SUS

)

 to secure the mounting plate on the gang box.

Use another four supplied screws to secure the mounting plate on the wall.

Route the cables through the cable hole of the mounting plate, and connect to the corresponding 

external devices’ cables.

Note:

 Apply Silicone sealant among the cable wiring area 

to 

keep the raindrop from entering.

Before you start:

 

According to the baseline on the mounting template, stick the mounting template on the wall or 

other surface, 1.4 meters higher than the ground.

Note:

 

Make sure the output of external power supply fulfils LPS.

Steps:

4

5

Insert the fingerprint module to the holes at the bottom of the main part.

Align the device with the mounting plate and hang the terminal on the 

mounting plate.

Make sure the two sheets on each side of the mount plate have been in the 

holes at the back of the device.

Use two supplied screws (SC-M4×12TP10-SUS) to secure the device and the 

mounting plate.

Apply 

Sililcone 

sealant

3m

2m

1

Installation

Close to Light

1

3

2

Hole1

Hole1

Hole1

Hole1

Hole2

Hole2

Hole2

Hole2

Hole3

Recommanded Height:1.40 m.

87 mm

196.8 mm

5

5

4

Mounting Template

Datum

Camera

IR Light

White Light

Screen

Card Presenting

Area

Fingerprint

Scanner

USB Interface

Wiring

Terminal

Power 

Interface

Debugging

Port

(For debugging 

only)

116.5 mm

290 mm

33 mm

PSAM Card

Card Slot

(Reserved)

SIM Card Card Slot

(Reserved)

IR Light

Network

Interface

Quick Start Guide

TimeWatch

 ULtraFace

 Series 