2.4 Connections of the front and rear panel of the FalseStart box

2.4.1 Front panel

At the front panel of the FalseStart box, there are in fact only two 
connections: the ‘headset’ connection in which the headset (or the 
extension cable of the headset) is plugged and the ‘Starting Pistol’ 
connection in which the cable of the start detector is plugged. The 
start detector is a small blue aluminum box, containing the built-in 
start sensor, and a  LED light to signal the starter the ready-or-not 
status   of   the   FalseStart   system.   The   start   detector   itself   should   be 
mounted on the pistol’s barrel as such that the distance to the pistol’s 
cylinder amounts to maximum 10cm. 

Further on the front panel you will find a printer, a display unit and 
other operating buttons, the function of which will be explained later 
on in this manual.

2.4.2 Rear panel

There are 5 connections on the rear panel.

1.

Battery 12V DC Connection

In this connection, a connector coming from the battery is permanently plugged. On the front of the caddy you can 
see a connector to charge the battery.

2.

Serial RS232 Connection

This is a connection that you can use in case you want to connect a personal computer to the system, to read the 
power curves of all athletes, and display them in a graphical waveform. Only used by specialists.

3.

Speaker Connection

Used to connect 

AN EXTRA, (OPTIONAL)

 

loudspeaker set. For example at the start of a 1500 meters race, the 

starter is not going to make use of the starting modules with built-in loudspeakers. In order to bring the sound of his 
voice and the starting pistol directly to the athletes, he can use a separate loudspeaker that can be plugged in this 
connection.

4.

MacFinish Connection

This connection is used when connecting the system to the MacFinish photo finish and timing system. You will find 
the same connection on the front of the caddy.

5.

Starting Blocks Connection

The extension cable to the starting blocks is plugged in here, which leads to the various cables connecting the 
starting modules (see page 5). You will find the same connection on the front of the caddy.

5

Содержание FalseStart II

Страница 1: ...Manual FalseStart Version 2012v1...

Страница 2: ...Start box 5 2 4 1 Front panel 5 2 4 2 Rear panel 5 3 OPERATION 6 3 1 Basic principle 6 3 2 Status screen 6 3 2 1 Adjusting the sound volume 6 3 3 The menus 7 3 3 1 Test blocks 7 3 3 2 St art training...

Страница 3: ...cs equipment please contact your local distributor or TimeTronics directly by email info timetronics be or call us at 32 0 14 23 19 11 Please also contact us if you have any remarks or advise regardin...

Страница 4: ...proximately 8 5 meters When looking at the time difference with respect to the moment at which both athletes hear the starting shot and taking into account the sonic speed 343 m s we can conclude that...

Страница 5: ...ivered in a carrying case are equipped with velcro straps on their bottom plates Simply tear off the loop part of those velcro straps and stick it onto the starting block The hook part of the velcro s...

Страница 6: ...on a connector coming from the battery is permanently plugged On the front of the caddy you can see a connector to charge the battery 2 Serial RS232 Connection This is a connection that you can use in...

Страница 7: ...5 Batt Indicates the battery voltage Recharge your battery when voltage drops below 11 5 Volt 6 Pistol When the start detector is plugged in the Starting Pistol connection on the front panel Conn ecte...

Страница 8: ...ndow appears on your display Now we can start testing our starting modules as follows Go to starting module 1 and give it a gentle kick You will hear one single beep At the same time number 1 appears...

Страница 9: ...ENTER You now enter the following display window Press one of the arrows to switch to Training ON Note when shutting down the FalseStart System the Training function will automatically be switched to...

Страница 10: ...a print out on paper see later A possible example 3 3 5 Race name Scroll to the race name that you want to select via the directional arrows and press the ENTER button Suppose we selected the 100m ra...

Страница 11: ...rmally the Ready command and the starting shot First use the arrow buttons to choose the number of races to print and press ENTER to start printing or READY to cancel the printing A possible example o...

Страница 12: ...panel 3 3 12 Meas uring Pref erences When selecting this menu you enter the following display window In here the standard IAAF settings relating to the fastest possible reaction time of a human being...

Страница 13: ...istol connected well Is the MacFinish operator ready Is the FalseStart system put into ready position If everything is OK the starter can start the race After the start of the race immediately the sta...

Страница 14: ...ned like this Now insert the paper in the crack like this At the same time press the FEED button on the printer s front panel until the paper roll comes sticking out sufficiently Next again attach the...

Страница 15: ...2012v1 Manual FalseStart II Copyright 2012 TimeTronics All rights reserved TimeTronics Lammerdries 23b B 2250 Olen Belgium Tel 32 0 14 23 19 11 Fax 32 0 14 23 20 24 14...

Отзывы: