34
Restore Data
Restore the data stored in the device or from the USB drive:
Go to Menu
>
Data Management
>
Press OK to Enter
>
Restore Data
>
Press OK to Enter
>
Select from USB Disk
>
Select the data to be restored
>
Start Restore
Access control
*for Face ID 4D only
Access Control options is used to set the Door Lock setting, Time Zone, Holidays and
Access Group.
Access Control Options settings
To set the parameters of the Door Lock and related equipment
To setup the Access Control:
Press Menu icon
>
Access Control
>
Access Control Options
• Door Lock Delay(s):
This value is the time period for the door to lock again after it un-
locks on successful verification. Default value is 10 second and the range is between
1-10
• Door Sensor Delay(s):
This function only works if door sensor is available. When a door
is not closing for a specified time, the sensor will trigger alarm system. Specify the
time of the delay. Default value is 10s, the range is 0-99s. Choose your preference.
• Door Sensor Type:
There are two types of door sensor available for door access which
are Normally Open (NO) and Normally Close (NC). Once a door sensor is available,
you have to choose the door sensor type. Default is None.
• Door Alarm Delays(s):
This function only works when there is alarm system installed
with Face ID. You can adjust the time before Face ID triggering an alarm system if
the door is not closed. A tap on the value will prompt a keypad. Input the value in
seconds. The default value is 30s.
• Retry Times To Alarm:
When the nummber of failed verification reaches the set value
(value ranges from 1 to 9), the alarm will be triggered. If the set value is None, the
alarm will not be triggered after failed verification.
• NC Time Period:
To set the time period for Normally Closed mode, so that no one can
gain access during this period.
• NO Time Period:
to set the time period for Normally Open, so that the door is always
unlocked during this period.
• Valid Holidays:
To set if NC Time Period or NO Time Period settings are valid in set
holida time period. Choose ON to enable the set NC or NO time period in holiday
• Speaker Alarm:
When the ‘Speaker Alarm’ is enabled, the speaker will raise an alarm
when the device is being dismantled.
• Reset Access Settins:
To restore access control parameters