TimeLine 71B008 Скачать руководство пользователя страница 7

Micro Lynx ACG Option Card 

ECC NO. 1019 

Page 7

 

73630 REV. C 

PROCEDURE (continued): 

11. The Option Card cable is a ribbon cable with four connectors attached.  On one end of 

the cable, the second connector is about 3.5" from the end.  Insert this end into 
connector J1 on the component side of the ACG Card.  The connector should be 
attached so that the cable falls away from the ACG Card, as illustrated in Figure 3. 

12. Position the ACG Card component side down with connector J1 toward the front of the 

System Unit.  Approximately 1.25" from the J1 connector, bend the Option Card cable 
under, so that it makes a right-angle turn (the unused connectors on the cable will face the 
chassis bottom). 

13. Insert the folded Option Card cable through the opening in the Option Card bracket.   

14. Lie the ACG Card flat on the Option Card bracket.  Slide the ACG Card against the 

back panel, so that the 

AES/EBU

 connector and the 

O.S. OUT

WORD OUT

 and 

CLOCK IN

 

jacks are seated in the appropriate cutouts in the back panel.  Insert the washers and 
nuts onto the BNC connectors.  Replace the mounting standoffs on the 9-pin connector. 

15. The corner of the ACG Card, with the black rubber bumper, will rest on the "L" 

bracket installed on the side of the chassis in Step 5.  Insert two phillips screws 
through the ACG Card into the Option Card bracket and tighten.  (See Figure 7.) 

 

Figure 7.  Install the ACG Card 

16. If the M3 Card is fitted, insert the Option Card cable connector into J1 on the M3 

Card.  If the VITC Card is fitted, insert the Option Card cable connector into J1 on the 
VITC Card. 

17. Connect the other end of the cable into J3 on the Main Board.  The unused connectors 

will lie in the open area in the middle of the System Unit, unless you have option cards 
installed. 

18. Replace the top cover and the six phillips screws. 

Содержание 71B008

Страница 1: ...TimeLine Part Number 71B009 ACG 2 Option Card PROCEDURE 1 Turn off the power and place the Micro Lynx System Unit on a static safe workstation Ground yourself and the workstation anti static mat 2 On...

Страница 2: ...anel to the right of the SYSTEM TALLY connector The bracket is no longer needed keep the phillips screws Figure 1 Remove Support Bracket 6 Hold the Option Card bracket so that the large cutout is face...

Страница 3: ...ay from the ACG Card as illustrated in Figure 3 Figure 3 Option Cable Installation 12 Position the ACG Card component side down with connector J1 toward the front of the System Unit Approximately 1 25...

Страница 4: ...n Card cable connector into J1 on the VITC Card 18 Connect the other end of the cable into J3 on the Main Board The unused connectors will lie in the open area in the middle of the System Unit unless...

Страница 5: ...acket 6 Remove the M3 Card if installed Remove the nut on the left threaded stud securing the front panel to the chassis 7 Hold the ACG Option Card bracket diagonally across the chassis with the cable...

Страница 6: ...age 6 73630 REV C Install the ACG Option Card 9 Reinstall the M3 Card if it was removed The ACG Card is mounted on the left side of the System Unit above the M3 Card 10 Remove the mounting standoffs f...

Страница 7: ...n the Option Card bracket Slide the ACG Card against the back panel so that the AES EBU connector and the O S OUT WORD OUT and CLOCK IN jacks are seated in the appropriate cutouts in the back panel In...

Страница 8: ...the component side of the ACG Card The connector should be attached so that the cable falls away from the ACG Card as illustrated in Figure 3 8 Position the ACG Card component side down with connecto...

Страница 9: ...tor into J1 on the VITC Card 13 Connect the other end of the cable into J3 on the Main Board The unused connectors will lie in the open area in the middle of the System Unit unless you have option car...

Отзывы: