background image

16

  Quick Programming Tips

•  Up to 6 timed temperature periods are allowed per day.
•  They can be edited or deleted by holding the time or temperature.
•  If there are less than 6 periods, new periods can be added using the + key.
•  The active repeats are shown in dark blue and active days for other pages 

are shown in turquoise. 

•  Days can be selected and deselected by touching the day required. 
•  The dots or grey squares show the number of pages, with the bold square 

being the active page.

•  If a day is de-selected, it shows grey; this would mean that the programme 

last will continue to run until the next active day with a programme  
takes over.

•  If there are grey days, a new page can be added using the + page button. 

If there are no grey days, new pages cannot be added because all the days 
would be active on one of the pages from that programme set. 

•  If individual day programming is required, this can be achieved by having 

only one active day per page until no additional pages can be added. 
(Page 1 M, Page 2 Tu, Page 3 W, Page 4 Th) etc. 

 

Note: On exiting programming, any days that are grey will be 
deleted. Days cannot be left inactive. If a day is missing, the last 
temperature set will be active until the next programmed day.

  Resetting the Thermostat

•  Put the thermostat into couple mode, (see page 8). Press + or - to see the 

following menu options; Couple, Time entry, programming, copy, technical, 
and reset. Press set to select. 

•  Technical can be used to re-calibrate the displayed temperature.
•  It is recommended that the Progr App is used to perform all 

programming operations, but changes made here at the thermostat  
will be reflected in the App on your phone.

Содержание TRTWIFI

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s Wi Fi Controlled Thermostat Model TRTWIFI...

Страница 2: ...ostat and install in accordance with the current IEE wiring and Building Regulations Check that the total load on the circuit including when this thermostat is fitted does not exceed the rating of the...

Страница 3: ...th weekly repeats Back Light Yes Operating Temperature Range 0 C to 40 C Set Temperature Range Minimum 5 C to maximum 35 C Temperature Adjustment 0 5 C steps Swing 0 5 or 1 0 C CE Compliant Dimensions...

Страница 4: ...t and pulses when in pairing mode The orange LED will flash quickly when there is a communication issue Manual Output Button functions only when there is no internet connection as an ON OFF button Gre...

Страница 5: ...x is ensured 5 6 Connect the live brown and neutral blue wires on the power box to a 230V AC supply from the wiring centre making sure the polarities match up accordingly with the wiring centre Refer...

Страница 6: ...r water gas pipes that may be hidden beneath the surface 5 12 Insert the rawl plugs into the holes that have been drilled 5 13 Connect the two white coloured wires from the flex of the power box to th...

Страница 7: ...ion Diagram The diagram below shows a typical thermostat wiring to a wiring centre The diagram below shows how the TRTWIFI would replace a typical thermostat setup Note Check boiler instructions befor...

Страница 8: ...connections from the power box white wires connect to the TRTWIFI terminals This wiring is volt free and is not polarity sensitive 7 Setup Note the mobile or tablet device must be connected to a 2 4...

Страница 9: ...Note User names and passwords cannot contain any spaces or special characters and must use letters and numbers only 7 5 Then press the button bottom right on phones screen to open the add devices men...

Страница 10: ...available device Once the App has found and configured the TRTWIFI to the network the Wi Fi Icon on the thermostat will be permanently displayed on the screen 7 10 During the pairing process the App...

Страница 11: ...t temperature can be overridden on the thermostat as a temporary override until the next programme change using the and buttons Mode Button The mode button is used to change between different operatin...

Страница 12: ...ple Store There are useful programming tips and help available on the Timeguard YouTube channel You can access the link directly from our website www timeguard com or go to the YouTube home page and s...

Страница 13: ...one This will override the programmed temperature until the next programmed change The symbol will show on the screen To revert back to the programmed temperature touch the symbol and the override wi...

Страница 14: ...n Mode Output is switched off unless the room temperature drops below 5 C Only one mode can be selected at any time Permanent OFF ON and holiday can be cancelled by returning the App to Auto mode or b...

Страница 15: ...14 15 Programme time Active days Set temperature Add new days 7 max New settings Number of pages dots...

Страница 16: ...15 This shows the times when a temperature change has been programmed The thermostat will maintain the programmed temperature until the next change...

Страница 17: ...rey days new pages cannot be added because all the days would be active on one of the pages from that programme set If individual day programming is required this can be achieved by having only one ac...

Страница 18: ...en when they download the App this will result in creating a main account Controls Allows the user to change the temperature swing between 0 5 and 1 0 and turn on the optimum start function and propor...

Страница 19: ...purchase and it will be replaced free of charge For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all...

Страница 20: ...csc timeguard com For a product brochure please contact HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com Qualified Customer Support Co ordinators will be on line to assist in...

Отзывы: