background image

Ins
tallation & Oper

ating Ins

tructions

RCD Single Sockets 

RCD01WAVN 

RCD Single White Socket – Active

RCD02WPVN 

RCD Single White Socket – Passive

RCD03MAVN 

RCD Single Metal Socket – Active

RCD04MPVN 

RCD Single Metal Socket – Passive

Содержание RCD01WAVN

Страница 1: ...p e r a t i n g I n s t r u c t i o n s RCD Single Sockets RCD01WAVN RCD Single White Socket Active RCD02WPVN RCD Single White Socket Passive RCD03MAVN RCD Single Metal Socket Active RCD04MPVN RCD Si...

Страница 2: ...Device 2 Safety Before installation or maintenance ensure the mains supply to the RCD fused connection unit is switched off and the circuit supply fuses are removed or the circuit breaker turned off...

Страница 3: ...ric pollution A warming of the casing during use is normal Do NOT use outside the service conditions For devices having a solid neutral ensure the correct polarity of the incoming supply connections s...

Страница 4: ...ed Trip Current 30mA RCD Type Double Pole suitable for 2 and 3 wire applications Breaking Capacity 250A Earth leakage Through Fault Withstand 1500A Operating Temp Range 5 C to 40 C Trip Speed Less tha...

Страница 5: ...rsion if set will retain closed contacts if the mains supply is interrupted essential for applications such as freezers The non latching version if set allows the contacts to open if the mains supply...

Страница 6: ...5 RCD01WAVN RCD02WPVN Blue Reset button R for RCD01WAVN Grey Reset button R for RCD02WPVN Red Test T button Status indicator shows Red for ON Green for OFF ON OFF Switch...

Страница 7: ...2x 3 5mm diameter fixing screws 1x Warning label 1x Instruction manual 1x Metal Surface Box RCD03MAVN RCD04MPVN Blue Reset button R for RCD03MAVN Grey Reset button R for RCD04MPVN Red Test T button St...

Страница 8: ...boxes it will be necessary to bend back the upper and lower fixing lugs to enable RCD to be fitted 6 1 Ensure the mains supply is switched off and the circuit supply fuses are removed or the circuit b...

Страница 9: ...ust be used on the inside of the back box entries to secure the gland or conduit The gland or conduit must not project into the back box beyond the lock ring a male adapter should be used within the b...

Страница 10: ...hould show Green This indicates the RCD had been tripped and power has been disconnected 8 3 RESET Press the Grey Blue Reset button marked R again the status indicator should show Red If all the above...

Страница 11: ...sional advice 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier i...

Страница 12: ...a product brochure please contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the store...

Отзывы: