3
4. Installation
• Ensure the mains supply is switched off
and the circuit supply fuses are removed
or the circuit breaker turned off.
• Remove the two bezel fixing screws,
and remove bezel from timer module
and wall plate.
• Ease the module forward without disconnecting,
so you have access to the wall plate
and loosen the screws on the terminal
block for both supply and load cables.
• Ensuring that the free terminals on the wall
plate are at the top, terminate the 230V
50Hz supply and load cables to the terminal
block ensuring correct polarity is observed
and that all bare conductors are sleeved.
Please note the connections are marked on
the rear side of the wall plate (see section 5.
Connection Diagram).
• Fit the wall mounting screws through the
wall plate and into the wall box threaded
holes, and tighten until the wall plate
is firmly fastened.
• Re-position the module back into place
ensuring the time indicator is on the bottom
right hand side, and the locating holes on
the timer are set correctly on the pegs
on the back plate.
• Re-fit the bezel over the timer module,
and secure to the wall plate with the
two fixing screws previously removed.