This may be necessary to add further lighting for instance and the following procedure for
removing the unit from its backplate should be followed:-
Insert the wire through the hole indicated in diagram F.
The terminals are now accessible. If adding lighting, ensure the unit’s rating is not
exceeded.
10. Accessing Terminals After Installation
8
If you experience problems refer to Troubleshooting Guide.
If problems still exist,
do not immediately return the unit to store.
Telephone the Timeguard Customer Helpline
020 8450 0515
Qualified Customer Support Co-ordinators will be on-line to
assist in resolving your query.
PROBLEM SOLUTION
night and day.
night, or PIR keeps activation at
random for no apparent reason
11. Troubleshooting
terminals may be transposed.
The unit may be suffering from false activation.
Cover the sensor lens completely with black PVC
tape. This will prevent the sensor from “seeing”
anything. If the unit now switches off after the
set time duration and does not re-activate, this
indicates that the problem was cause by false
activation. The problem may be solved by slightly
adjusting the direction/angle of the sensor head
(see previous section). If however, the unit
the unit is faulty and should be replaced.