10

4. Battery

A battery is provided with the following control units and kits 
-  EACP1PR, EASSCP1PR, EACP4PR or EASSCP4PR and cannot 
be fitted to other types.

To fit the battery remove it from the holder and turn it round 
and offer it up to the connector and after correct polarity is 
ensured press the battery into the connector.

The battery takes 48 hours to get to full charge from when first 
connected to the control unit and mains voltage applied to the 
L and N terminals.

An illustration of full reserve capability is as follows:

Single zone system

Typically 4 days on standby with 
2 hours continuous alarm.

Four zone system

1 day on standby with 30 minutes 
continuous alarm (1 zone only).

Caution. Danger of explosion if battery is 
incorrectly connected. Replace only with same 
type of NIMH rechargeable battery.

Important. 

Ensure battery is inserted with correct 

polarity. Do not force battery onto contacts.

Battery Disposal

When battery has reached end of useful life insulate terminals 
and consult your local authority about disposal. 

DO NOT DISPOSE OF IN FIRE.

Содержание EACP1

Страница 1: ...Unit Single Zone Stainless Steel Control Unit Plastic Reset Unit Stainless Steel Reset Unit Plastic Over Door Unit Stainless Steel Over Door Unit Pull Cord Unit Four Zone Plastic Control Unit Four Zo...

Страница 2: ...Plastic Over Door Unit EADF1 Stainless Steel Over Door Unit EASSDF1 Pull Cord Unit EAPC1 Four Zone Plastic Control Unit EACP4 with battery back up EACP4PR Four Zone Stainless Steel Control Unit EASSCP...

Страница 3: ...2 Typical Single Zone System Available as EASZK Pull Cord Unit Over Door Unit Reset Unit Single Zone Control Unit 2 wire 2 wire 2 wire Fused Spur not supplied...

Страница 4: ...of the four zone Control Units in combination with the appropriate number of Reset Units Over Door Units and Pull Cord Units There are no adverse effects if any of the four zone control units input c...

Страница 5: ...ted intermittently and will both be further reassuring the person in distress At the Control Unit the alarm light and the sounder are activated continuously Either the Over Door Unit or the Control Un...

Страница 6: ...ot connect to mains supply Wiring and Fixing Holes Final page gives expanded view of this diagram MUST be switched off at all times while installation is in progress The installation shall be carried...

Страница 7: ...ional wiring rules Bring the mains supply cable 1mm2 TFE into the box and connect the Live and Neutral wires to the terminals on the Control Unit marked L and N respectively see diagram Ensure the len...

Страница 8: ...to the wall box using the screws provided Insert battery into battery holder Connections are as above diagram for a single zone system The four zone system is similar except that the four zone Contro...

Страница 9: ...oor knot the cord at required height Hold the unit backplate in position on the ceiling and mark through the xing holes on the unit backplate and drill and plug if necessary holes suitable for four No...

Страница 10: ...input see diagram Fix the Reset Unit to the wall box using the screws provided 3 3 Over Door Unit This should be sited to attract appropriate personnel to the area where assistance is required An exa...

Страница 11: ...voltage applied to the L and N terminals An illustration of full reserve capability is as follows Single zone system Typically 4 days on standby with 2 hours continuous alarm Four zone system 1 day on...

Страница 12: ...ld behave as described in the second paragraph of section 2 Having observed this to be the case press the Reset button on the Control Unit to end the alarm Pull the pull cord again and verify each uni...

Страница 13: ...running on backup battery check that the battery is fully charged Blue LED on Control Unit is continuously ON and cannot be reset 2 wire link is shorting Battery is too low Check there is no short ci...

Страница 14: ...ve battery Metal Hydride rechargeable PP3 9Volt Alarm Output DC voltage through 470 ohm resistor Do not connect to mains voltage source Maximum pull force on pull cord 200N Reset button marking Visual...

Страница 15: ...Unit Rear Reset Selection Connector for incoming mains supply Transformer Battery Holder Back up PR versions only Fixing Holes Fixing Holes Cover Fixing Holes Pull Cord Hole Fixing Holes Fixing Holes...

Страница 16: ...For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND 020 8452 1112 or email csc timeguard com HELPLINE 020 8450 0515 67 058 192 Iss 1...

Отзывы: