3. Selecting intercom sites and cabling

3.1 Intercom sites

The internal intercom should be located at a convenient position for all potential users 
at the height indicated in fi g 3a and at a maximum distance of 70m from the external 
intercom. If all the users are signifi cantly above or below average height then a different 
mounting height may be considered appropriate.

The external intercom should be sited in an area away from driving rain 
and surface water, out of direct sunlight as far as possible and protected by the 
minimum of an open porch in a position readily accessible to potential entrants. It 
should be mounted at the height indicated in fi g 3b.

Fig 3a

Internal intercom 

mounting height

Fig 3b

External intercom mounting 

height and coverage

3.2 Cabling

Connection between the internal and external intercoms is by 2 core cable and must not 
be more than 70m long. Two core (13 x 0.2) bell fl ex is suitable.

A 15m length of 2 core cable is supplied with the kit terminated at one end with an RJ-
11 plug which connects to the RJ-45 socket on the internal intercom. Existing bell cable 
runs can be made use of.

The cable run should be kept at least 100mm away from mains cables to avoid 
interference.

A second relatively short 2 core cable will be required between the external intercom 
and the door catch (if used).

A further 2 core cable will be required to extend (if necessary) the cable between the 
external intercom and the second internal intercom for the DCEX4.

DCEX3_DCEX4_Instructs_1.3.indd   4

DCEX3_DCEX4_Instructs_1.3.indd   4

30/1/07   11:09:03 am

30/1/07   11:09:03 am

Содержание DoorCom DCEX3

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS AUDIO DOOR ENTRY SYSTEM Model DCEX3 Single Channel Colour DCEX4 Twin Channel Colour DCEX4 DCEX3 DCEX3 4...

Страница 2: ...ew If operation with an electric door catch is required then part DCLR is a fail power off secure catch available from Timeguard See fig 2 for wiring of this part An additional two core cable run usin...

Страница 3: ...18 Internal intercom Fig 2 Wiring diagram DCEX3 single channel External intercom Door catch DCEX4 twin channel Door catch Alternative low voltage supply connection Alternative low voltage supply conn...

Страница 4: ...ed at the height indicated in fig 3b Fig 3a Internal intercom mounting height Fig 3b External intercom mounting height and coverage 3 2 Cabling Connection between the internal and external intercoms i...

Страница 5: ...o the terminals of the same colour on the external intercom particularly important if an extension cable is used If a DCEX4 is being installed then a second cable will be required to connect to the ad...

Страница 6: ...the two fixing screws see fig 5 and keeping the rear of the case clear of the angle bracket 15 push the internal intercom downwards to locate the screws on the narrower part of the keyhole fixing Push...

Страница 7: ...case of damage to the product unplug the mains adaptor from the mains supply to avoid any possibility of electric shock and have the damage examined by a competent person 3 When laying cabling ensure...

Страница 8: ...0 2 bell flex Power consuption Standby 4W In operation 16W Operating ambient temperature range 10 C to 50 C external intercom 35 C max internal intercom mains adaptor Ringtone volume 80dBA at 0 3m max...

Отзывы: