Control functions (cont.)

 

 

 

 

 

 

 

 

 

(6)

 

Output enable/disable –

 12 

position dip switch

 

 

(Channels set to OFF are disabled)

 

(7)

 

Time adjustment control

 

 

Output ON time:

 

120 

 300 

Sec.

 

 

Output OFF time:

 

 30 

Sec.

 

 

Run time:

   

 

 30 

Min.

 

(8)

 

Output indication (12 LED

s)

 

 

LED

s indicate when a channel is ON

 

 

 

 

 

Press the Power button.

 

 

Press and hold the select switch until the OUTPUT ON 

LED blinks.  Adjust the Time Adjust pot until the desired 

time is shown on the display.

 

 

Press the select button again and the OUTPUT OFF 

LED will blink.  Adjust the Time Adjust pot until the 

desired time is shown on the display.

 

 

Press the select button again and the RUN TIME LED 

will blink.  Adjust the Time Adjust pot until the desired 

time is shown on the display.

 

 

All settings are stored in non

-

volatile memory. 

 

MODEL 36

 

12 Channel Splash Pad Controller

 

READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.

 

KEEP THIS DATA SHEET FOR FUTURE REFERENCE 

 

(1)

 

Power switch –

 

turns controller on and off.

 

(2)

 

LED Indicators:

 

 

POWER –

 

Indicates unit is on.

 

 

OUTPUT ON –

 

Indicates when outputs are on

 

 

OUTPUT OFF –

 

Indicates when outputs are off

 

 

RUN TIME –

 

Indicates the total cycle time between 

 

 

external triggers.

 

 

ERROR –

 

Indicates an error in setup 

 

 

 

LED

s will blink if potentiometer is set to 

  

 

 

minimum, maximum or if the number of outputs 

 

 

to activate (switches 3 & 4) is greater than the 

 

 

number enabled (switch S1).

 

 

 

Note: The number of outputs enabled should 

 

 

be two times the number to be activated.

 

(3) Seven segment display

 

 

During 

set up

, the display will show the ON time, 

 

 

OFF time or CYCLE time.

 

 

During 

normal run

, the display will count down the 

 

 

ON or OFF, or show PLA  

(“

PLA

” 

indicates the 

 

 

controller is waiting for a trigger). 

 

(4) Function select switch

 

 

Used to pick the parameter to adjust (

setup

) or to 

 

scroll through the settings (

normal

)

 

(5) Control functions (4 position dip switch)

 

 

Position 1

 

 

 

 

 

 

Position 2

 

 

 

 

Telephone:

 

Main 

(918) 438

-

1220

 

 

 

 

Sales 

(800) 862

-

2875

 

Fax:

  

 

 

 

(918) 437

-

7584

 

 

E

-

mail:

   

sales@time

-

mark.com

 

Internet:

  

http://www.time

-

mark.com

 

03/2021

 

© 2021   

TIME MARK CORPORATION

 

11440  Eas t Pine Stree t

 

Tuls a,  Ok lahom a  74116

 

MODEL 36 CONTROL FUNCTIONS

 

BASIC SETUP

 

Position 3

 

Position 4

 

Number of outputs

 

OFF

 

OFF

 

1

 

ON

 

OFF

 

2

 

OFF

 

ON

 

3

 

ON

 

ON

 

4

 

ON

 

Output in sequence

 

OFF

 

Output is random

 

ON

 

Random time ON up to value set by pot

 

OFF

 

Exact time set by pot

 

TIME ADJUST

120 - 300 SEC.

2

3

4

5

6

7

8

9

1

10

11

12

OUTPUTS

1 2 3 4

1

OFF

OFF

12

FUNCTIONS OUTPUTS ENABLE

Switch 3

OFF

ON

OFF

ON

Switch 4

OFF

OFF

ON

ON

OUTPUTS

1

2

3

4

FUNCTIONS:

TIME MARK

www

.time-mark

.c

o

m

12 CHANNEL RANDOMIZER / SEQUENCER

MODEL 35

ENGINEERED AND BUILT IN THE U.S.A.

SELECT

PO

WER

O

U

T

P

UT 

ON

O

U

T

P

UT 

OF

F

RUN 

TI

ME

POWER

ERR

OR

Switch 1 - ON 

output

in sequence

OFF 

output

is random

Switch 2 - Random on time 

up to value set

Exact on time

set by pot

by pot

1

2

3

4

5

6

7

8

 

Содержание 36

Страница 1: ...mensions 12 0 x 5 5 x1 88 Weight 2 5 lbs Country of Origin U S A 12 00 5 50 1 88 1 36 11 50 5 00 10 13 DESCRIPTION The Time Mark Model 36 Splash Pad Controller can sequence up to 12 channels with one to four channels active at a time The controller offers 2 modes of operation Sequence Mode Once triggered the unit will activate up to four outputs for a predetermined time deactivate those outputs an...

Страница 2: ...TING WIRING THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL Installation and Setup Instructions Telephone Main 918 438 1220 Sales 800 862 2875 Fax 918 437 7584 E mail sales time mark com Internet http www time mark com 03 2021 2021 TIME MARK CORPORATION 11440 East Pine Street Tulsa Oklahoma 74116 POWER AND TRIGGER CONFIGURATIONS 1 Connect the Model 36 to 24VAC L1 L2 and earth g...

Страница 3: ...annel Splash Pad Controller READ ALL INSTRUCTIONS BEFORE INSTALLING OPERATING OR SERVICING THIS DEVICE KEEP THIS DATA SHEET FOR FUTURE REFERENCE Telephone Main 918 438 1220 Sales 800 862 2875 Fax 918 437 7584 E mail sales time mark com Internet http www time mark com 03 2021 2021 TIME MARK CORPORATION 11440 East Pine Street Tulsa Oklahoma 74116 RELAY OUTPUT PIN HEADER SWITCH L1 SWITCH L2 DRY CONTA...

Страница 4: ...outputs to activate switches 3 4 is greater than the number enabled switch S1 Note The number of outputs enabled should be two times the number to be activated 3 Seven segment display During set up the display will show the ON time OFF time or CYCLE time During normal run the display will count down the ON or OFF or show PLA PLA indicates the controller is waiting for a trigger 4 Function select s...

Страница 5: ...1 turning on a random 3 outputs at a time for 3 minutes followed by an off time of 3 seconds between feature changes Outputs Enable switches are as set as follows Switches Down ON 1 7 10 and 11 Switches Up OFF 8 9 and 12 Functions switches are set as follows Switches Down ON 4 Switches Up OFF 1 3 WARRANTY This product is warranted to be free from defects in materials and workmanship for one year S...

Страница 6: ...ll us at 800 862 2875 Telephone Main 918 438 1220 Sales 800 862 2875 Fax 918 437 7584 E mail sales time mark com Internet http time mark com 03 2021 2021 TIME MARK CORPORATION 11440 East Pine Street Tulsa Oklahoma 74116 ...

Отзывы: