Control functions (cont.)
(6)
Output enable/disable –
12
position dip switch
(Channels set to OFF are disabled)
(7)
Time adjustment control
Output ON time:
120
–
300
Sec.
Output OFF time:
1
–
30
Sec.
Run time:
5
–
30
Min.
(8)
Output indication (12 LED
’
s)
LED
’
s indicate when a channel is ON
Press the Power button.
Press and hold the select switch until the OUTPUT ON
LED blinks. Adjust the Time Adjust pot until the desired
time is shown on the display.
Press the select button again and the OUTPUT OFF
LED will blink. Adjust the Time Adjust pot until the
desired time is shown on the display.
Press the select button again and the RUN TIME LED
will blink. Adjust the Time Adjust pot until the desired
time is shown on the display.
All settings are stored in non
-
volatile memory.
MODEL 36
12 Channel Splash Pad Controller
READ ALL INSTRUCTIONS BEFORE INSTALLING, OPERATING OR SERVICING THIS DEVICE.
KEEP THIS DATA SHEET FOR FUTURE REFERENCE
(1)
Power switch –
turns controller on and off.
(2)
LED Indicators:
POWER –
Indicates unit is on.
OUTPUT ON –
Indicates when outputs are on
OUTPUT OFF –
Indicates when outputs are off
RUN TIME –
Indicates the total cycle time between
external triggers.
ERROR –
Indicates an error in setup
LED
’
s will blink if potentiometer is set to
minimum, maximum or if the number of outputs
to activate (switches 3 & 4) is greater than the
number enabled (switch S1).
Note: The number of outputs enabled should
be two times the number to be activated.
(3) Seven segment display
During
set up
, the display will show the ON time,
OFF time or CYCLE time.
During
normal run
, the display will count down the
ON or OFF, or show PLA
(“
PLA
”
indicates the
controller is waiting for a trigger).
(4) Function select switch
Used to pick the parameter to adjust (
setup
) or to
scroll through the settings (
normal
)
(5) Control functions (4 position dip switch)
Position 1
Position 2
Telephone:
Main
-
(918) 438
-
1220
Sales
-
(800) 862
-
2875
Fax:
(918) 437
-
7584
E
-
mail:
sales@time
-
mark.com
Internet:
http://www.time
-
mark.com
03/2021
© 2021
TIME MARK CORPORATION
11440 Eas t Pine Stree t
Tuls a, Ok lahom a 74116
MODEL 36 CONTROL FUNCTIONS
BASIC SETUP
Position 3
Position 4
Number of outputs
OFF
OFF
1
ON
OFF
2
OFF
ON
3
ON
ON
4
ON
Output in sequence
OFF
Output is random
ON
Random time ON up to value set by pot
OFF
Exact time set by pot
TIME ADJUST
120 - 300 SEC.
2
3
4
5
6
7
8
9
1
10
11
12
OUTPUTS
1 2 3 4
1
OFF
OFF
12
FUNCTIONS OUTPUTS ENABLE
Switch 3
OFF
ON
OFF
ON
Switch 4
OFF
OFF
ON
ON
OUTPUTS
1
2
3
4
FUNCTIONS:
TIME MARK
www
.time-mark
.c
o
m
12 CHANNEL RANDOMIZER / SEQUENCER
MODEL 35
ENGINEERED AND BUILT IN THE U.S.A.
SELECT
PO
WER
O
U
T
P
UT
ON
O
U
T
P
UT
OF
F
RUN
TI
ME
POWER
ERR
OR
Switch 1 - ON
output
in sequence
OFF
output
is random
Switch 2 - Random on time
up to value set
Exact on time
set by pot
by pot
1
2
3
4
5
6
7
8