background image

 12 individual outputs 

 

 3 Output Options

 

 Sequence or Random Modes

 

 Random or Adjustable Time On/Off 

 

 Remote Start (2 wire or 3 wire)

 

 Engineered and Built in the U.S.A.

 

DIMENSIONS

 

MODEL 36 

Splash Pad Controller

 

Telephone:

 

Main 

(918) 438

-

1220

 

 

 

 

Sales 

(800) 862

-

2875

 

Fax:

  

 

 

 

(918) 437

-

7584

 

 

E

-

mail:

   

sales@time

-

mark.com

 

Internet:

  

http://www.time

-

mark.com

 

03/2021

 

© 2021   

TIME MARK CORPORATION

 

11440  Eas t Pine Stree t

 

Tuls a,  Ok lahom a  74116

 

SPECIFICATIONS

 

Model

 

36

 

Input voltage

 

24VAC +/

-

10%

 

Power consumption

 

12W

 

Signal input (trigger)

 

2 wire / 3 wire

 

Display type

 

7 segment LED  / 17 LED

s

 

Output

 

12 relays (SPST)

 

Output configuration

 

See output setup

 

Surge protection

 

1500W (10/1000 µs)

 

Circuit breaker

 

500mA*

 

Operating temp.

 

 

130°F

 

Humidity

 

 90% 

non

-

condensing

 

Dimensions

 

12.0”

5.5”

x1.88

 

Weight

 

2.5 lbs.

 

Country of Origin

 

U.S.A.

 

12.00"

5.50"

1.88"

1.36"

11.50"

5.00"

10.13"

DESCRIPTION

 

 

The Time Mark 

Model  36  Splash  Pad  Controller

 can 

sequence up to  12 channels  with  one to four channels 

active  at  a  time.  The  controller  offers  2  modes  of 

operation:

 

 

Sequence  Mode:  Once  triggered,  the  unit  will  activate 

up to four outputs for a predetermined time, deactivate 

those  outputs  and  then  repeat  with  the  next  outputs  in 

sequence. 

 

 

Random Mode: Once triggered, the unit will activate up 

to four outputs for a random amount of time (120 to 300 

sec.).    After  that,  the  unit  will  deactivate  those  outputs 

 

(1 to 30 sec.), then pick a new set of outputs.

 

 

In  either  mode:  you  can  adjust  the  total  run  time,  the 

number  of  outputs  (up  to  four),  the  length  of  time  they 

stay on and the length of time before the next group of 

outputs come on. 

 

 

Custom programming is available from the factory.

 

* Circuit breaker protects Model 36 only

 

Содержание 36

Страница 1: ...mensions 12 0 x 5 5 x1 88 Weight 2 5 lbs Country of Origin U S A 12 00 5 50 1 88 1 36 11 50 5 00 10 13 DESCRIPTION The Time Mark Model 36 Splash Pad Controller can sequence up to 12 channels with one to four channels active at a time The controller offers 2 modes of operation Sequence Mode Once triggered the unit will activate up to four outputs for a predetermined time deactivate those outputs an...

Страница 2: ...TING WIRING THIS DEVICE SHOULD BE INSTALLED AND SERVICED BY QUALIFIED PERSONNEL Installation and Setup Instructions Telephone Main 918 438 1220 Sales 800 862 2875 Fax 918 437 7584 E mail sales time mark com Internet http www time mark com 03 2021 2021 TIME MARK CORPORATION 11440 East Pine Street Tulsa Oklahoma 74116 POWER AND TRIGGER CONFIGURATIONS 1 Connect the Model 36 to 24VAC L1 L2 and earth g...

Страница 3: ...annel Splash Pad Controller READ ALL INSTRUCTIONS BEFORE INSTALLING OPERATING OR SERVICING THIS DEVICE KEEP THIS DATA SHEET FOR FUTURE REFERENCE Telephone Main 918 438 1220 Sales 800 862 2875 Fax 918 437 7584 E mail sales time mark com Internet http www time mark com 03 2021 2021 TIME MARK CORPORATION 11440 East Pine Street Tulsa Oklahoma 74116 RELAY OUTPUT PIN HEADER SWITCH L1 SWITCH L2 DRY CONTA...

Страница 4: ...outputs to activate switches 3 4 is greater than the number enabled switch S1 Note The number of outputs enabled should be two times the number to be activated 3 Seven segment display During set up the display will show the ON time OFF time or CYCLE time During normal run the display will count down the ON or OFF or show PLA PLA indicates the controller is waiting for a trigger 4 Function select s...

Страница 5: ...1 turning on a random 3 outputs at a time for 3 minutes followed by an off time of 3 seconds between feature changes Outputs Enable switches are as set as follows Switches Down ON 1 7 10 and 11 Switches Up OFF 8 9 and 12 Functions switches are set as follows Switches Down ON 4 Switches Up OFF 1 3 WARRANTY This product is warranted to be free from defects in materials and workmanship for one year S...

Страница 6: ...ll us at 800 862 2875 Telephone Main 918 438 1220 Sales 800 862 2875 Fax 918 437 7584 E mail sales time mark com Internet http time mark com 03 2021 2021 TIME MARK CORPORATION 11440 East Pine Street Tulsa Oklahoma 74116 ...

Отзывы: