Full Technical specification available upon request. Contact [email protected] for PDF.
Instructions for new installations:
1)
Grasp the fire hood by its sides and carefully fold inwards
to reduce its bulk. Push it through the aperture with its top
uppermost, ensure that a grip on the fitting straps is
maintained through the process.
2)
Whilst in the ceiling void, carefully shape the fire hood
with an inverted screwdriver handle (or similar blunt object),
push it up into the fire hood and move it around to
completely open out the cover.
Note: Do not use any sharp tools as this may damage the
product.
3)
Secure the fire hood: Hold the fitting straps, align pins or
tacks with the plasterboard and push through the hole and
into the plasterboard. Any excess material on the straps can
be removed or secured so that it will not intervene with the
installation, luminaire or performance.
Round Fire Hood
Recycling Advice:
Waste Electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check
with your local authority or retailer for recycling advice.
Product Code
780862
Size (mm)
150x150x150
Colour
White
Minimum Clearances
Overall Width: Low V80mm
Overall Width: Mains H100mm
Fire Rating Information
BS476 Part 23 Compliant.
Covered for 66 minutes of Fire Protection.
Minimum Clearances:
Overall Width: Low V80mm
Overall Width: Mains H100mm
Height
+25mm
Fold fire hood to
allow it to enter the
aperture.
Use an inverted
screwdriver to shape
the fire hood in the
ceiling void.
Equally space fire hood around cut out. Bend and
secure strap to suit aperture.
Use pliers or cutters to
break off or fold under
any excess.
Pin
Tack