Time Guard PDFM1500 Скачать руководство пользователя страница 10

9

9. 

Technical Specifications

Motion Detection Range: 

Presence Detection Range: 

Detection Angle:

Power Supply:

Maximum Switchable Load: 

 

Time On Adjustment:

Dusk Level Adjustment:

Environmental Protection:

Up to 10 metres diameter (4.5m Radius)  
at mounting height of 3m

Up to 3 metres diameter (1.5m Radius)  
at mounting height of 3m

360º

230 V AC ~ 50Hz

1500W Halogen or Fluorescent/low  
energy lighting.

Not suitable for discharge lighting. 

250W fan load

1 minute – 30 minutes

Day & night or night only operation

IP44

Содержание PDFM1500

Страница 1: ...360 Flush Mount Ceiling PIR Light Controller Model PDFM1500 I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s...

Страница 2: ...nceof thelight shining intoyour neighbourswindows etc Please see Selectinga Locationfor informationon choosingtheoptimumlocationfor any security light controlled by this unit A B Side View Top View 3m...

Страница 3: ...aylight night onlyoperation ight Pollution and noyanceover lightingan area iateneighbours Light rrectly installinga unit or belimited by carefully and positionof your unit ght spreadon all halogen dby...

Страница 4: ...es as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 3m C...

Страница 5: ...uitable for connection to a 230 V ac 50Hz electricity supply It is suggested that 3 core round flexible cable of 1 5 sq mm gauge is used An isolating switch should be installed to switch the power to...

Страница 6: ...NEUTRAL Blue N LIVE Brown L1 Load When wiring is complete fit the cable clamp wiring cover to the sensor unit with the 2 screws provided diagram E Set the two adjustment controls on the side of the un...

Страница 7: ...uminate Now stand still until the lamp extinguishes this should take approx 5 seconds Start moving again after 2 seconds As you cross each zone the lamp will illuminate Repeat the above walking at var...

Страница 8: ...n a clockwise direction until a point is reached where the lamp illuminates in response to a hand moving below the unit Leave the control set at this point At this position the unit should become oper...

Страница 9: ...r false activation from heat wind or reflective source Check that the power is switched ON at the power supply or isolation switch Turn OFF the power to the unit and check the wiring connections Check...

Страница 10: ...t Dusk Level Adjustment Environmental Protection Up to 10 metres diameter 4 5m Radius at mounting height of 3m Up to 3 metres diameter 1 5m Radius at mounting height of 3m 360 230 V AC 50Hz 1500W Halo...

Страница 11: ...re within 3 years of the date of purchase please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge For years 2 and 3 or any difficulty in the f...

Страница 12: ...imeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact Zerofour September 2011 or email helpline time...