The TIME setting controls how long the unit remains illuminated following activation and after  
all motion ceases.
(See diagram E the time adjustment knob is indicated by the "Clock" symbol).
The minimum time (fully anti-clockwise) is approx. 5 seconds, whilst the maximum time (fully 
clockwise) is approx. 18 minutes. Set the control to the desired setting between these limits*.

* When using compact fluorescent lamps set the ON time to a minimum of 10 minutes. 
This will increase the lamp life but will not detract from the energy saving from using 
this type of lamp.

The DUSK control determines the level of darkness required for the unit to start operating.  
The setting is best achieved by the procedure below:
(See diagram E. the Dusk adjustment knob is indicated by the ‘Moon’ and ‘Sun’ symbols).
Set the DUSK control knob fully anti clockwise. Wait until darkness falls.
When the ambient light level reaches the level of darkness at which you wish the lamp to become 
operative (i.e. at dusk) SLOWLY rotate the control in a clockwise direction until a point is reached 
where the lamp illuminates. Leave the control set at this point.
At this position the unit should become operative at approximately the same level of darkness 
each evening. Observe the operation of the unit. If the unit is starting to operate too early  
(i.e. when it is quite light) adjust the control slightly anti-clockwise. If the unit starts to operate 
too late (i.e. when it is very dark). Adjust the control slightly clockwise.
Continue to adjust until the unit operates as desired.

Masking the Sensor Lens

To restrict the sensor coverage, preventing detection in unwanted areas, mask the sensor lens 
using the masking label provided in the accessory pack (see diagram F). For your information,  
the top section of the lens covers long range detection, the bottom covers short range. Similarly 
the left and right lens sections cover the left and right detection areas respectively.

Manual Override Mode

The light can be switched on for longer time periods by use of the Manual Override Mode.  
This can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker twice (OFF/ON, OFF/ON) within 2 seconds.  
The unit will now illuminate continuously for the user defined time, between 1 – 8 hours, or 
until the unit is switched back into auto mode. The ON time can be set by rotating the centre 
adjustment knob as required. See diagram E. This time adjustment is factory set to 1 hour  
(Fully anti-clockwise is 1 hour, fully clockwise is 8 hours).
Note: If the light is still ON at dawn, before the set time expires, it will automatically switch OFF. 
To switch the unit back into Auto Mode, flick the internal wall switch/circuit breaker OFF/ON once 
within 1 second. The unit will return to Auto Mode. 

Содержание MLB98

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 60W Multi PIR Bulkhead Model MLB98 Black...

Страница 2: ...horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimu...

Страница 3: ...he holes Pierce the grommet and pass the cable through the grommet Clamp the cable to the rear of the unit before securing the unit to the wall Fit grommet into its location hole ensuring a good seal...

Страница 4: ...es from the unit Each time you are detected the lamp will illuminate Now stand still until the lamp extinguishes this should take approx 5 seconds Start moving again when you are detected again the la...

Страница 5: ...e too early i e when it is quite light adjust the control slightly anti clockwise If the unit starts to operate too late i e when it is very dark Adjust the control slightly clockwise Continue to adju...

Страница 6: ...me can be set by rotating the centre adjustment knob as required See diagram E the adjustment knob is identified by the letter T inside a circle This time adjustment is factory set to 1 hour Please no...

Страница 7: ...th one second and the unit will return to Automatic Mode The light will illuminate only when motion is detected You may not be allowing the unit time to complete it s warm up period Stand well out of...

Страница 8: ...If the PIR still activates the setting is still too high Repeat the above procedure until the PIR does not activate when you enter the detection area Refer to previous section for more details Unit ma...

Страница 9: ...8 N L L1 Less sensitive More sensitive Top View 200 Side View 12m 2 5m A C B D Terminal cover...

Страница 10: ...9 E Lens Mask Restrict long detection Restrict short detection Restrict RHS detection Restrict LHS detection Dusk Dawn Override Holiday Mode Time F...

Страница 11: ...it will be replaced free of charge The lamp supplied is not included in the warranty For years 2 to 5 or any difficulty in the first year telephone our helpline on 020 8450 0515 Note A proof of purcha...

Страница 12: ...400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact For assistance with the product please contact Zerofour September 2014 or em...

Отзывы: