electric oil felled radiator

Important precautions.

1. Read this manual carefully prior to use of the unit to get a detailed 

understanding of the features of oil filled radiators.
2. To prevent the risk of an electric shock, always disconnect the unit from 

the mains, when it is not used. Remember that there is a slight chance of 

an electric shock due to static voltage even if the unit is switched off.
3. Never use the unit in a situation when it can come in contact with 

water (nearby a bath-room, a swimming pool, etc).
4. Never connect the unit to electric mains when it is damp (wet).
5. If you discover any damage of the power cord, never switch on the unit! 

In this case we recommend to return the unit to an authorized service 

center for an adequate repair. Never try to repair the power cord on your 

own! It can harm your health, as well as void the guarantee maintenance 

of the unit.
6. Never use the unit outside.
7. It is forbidden to disassemble the unit on your own! It can harm your 

health, as well as void the guarantee maintenance of the unit.
8. The lines of Timberk oil filled radiators T

OR 31...RRX, TOR 31...EHX I

 are 

additionally equipped with a built-in fan heater, located on the unit's 

front panel. It is forbidden to close the fan heater inlet and outlet either 

by hands or any objects. Failure to do so will result in breakdown of the 

unit. 
9. It is forbidden to operate the unit in a horizontal or inclined position! It 

may result in both failure of the unit and an accident.
10. The unit must always be kept watched, especially if there are children 

nearby the unit. Always watch out for children not to touch the unit by 

hand and not to use it for games. Also be sure that very old or disabled 

people couldn't use the unit (operating or switched off) by chance  they 

can accidentally get hurt.
11. Prior to preventive cleaning of the unit, always switch off the unit (the 

power regulator must be in OFF position   switched off ) and disconnect 

it from the mains by unplugging it from an electric outlet.
12. Never pull the power cord and do not disconnect (unplug) the cord's 

plug abruptly.
13. Store the unit in a cool or warm place. Never store the unit in damp 

rooms! We recommend you not to discard the packing if you are to store 

the unit for several months.
14. Pay attention to the fact that the radiator is equipped with a 

European-standard plug matching the standard European-standard 

outlet. The European-standard plug of the power cord must go into the 

IMPORTANT!

Timberk electric oil filled radiator contains a certain amount of specially 

formulated oil. The oil is contained in radiator's sections. In case when 

during repair it is required to open the oil-containing container (so-

called radiator section), repair must be carried out either in a Timberk 

authorized service center or at the manufacturing plant. Repair must be 

performed  by  qualified  specialists!  Therefore,  if  you  detected  an  oil 

leakage from the oil-containing sections of the radiator, contact only the 

abovementioned  places.  Also  you  must  follow  rules  regarding  oil 

disposal after opening of the unit in compliance with requirements of 

Environmental Laws and Regulations, currently in effect in your country.

European-standard outlet without any effort. If the Europlug enters the 

outlet tightly or doesn't enter it at all, please, turn the plug vertically by 

180° and try again. If you still cannot plug it then you need to call for an 

electrician to replace the electric outlet by the one matching a Europlug. 

Never switch on the unit if the plug is not fully connected to the outlet.
In case of unit's malfunction, please, contact the nearest Timberk Service 

Center for a consult and repair. You can always find addresses of service 

centers in the attachment to your guarantee card or on our web-site 

www.timberk.com in the  Service  section.

Air ionization function.

*

Air ionizer is an independent device and can operate even when the unit 

mode is switched off. Turning on the ionizer you make room air cleaner 

and more useful, preserving the environmental balance of your space. 

Useful negative air ions, generated by you air ionizer, destroy malignant 

bacteria, as well as reduce the content of harmful impurities in the air.

How to use the air ionizer?

1. Turn on the ionizer by means of a key switch, located on the unit's side 

panel. Press this key again and you will turn off the ionizer.
2. For the ionizer to operate it is sufficient to connect you radiator to the 

mains (see  Important precautions  to make everything right and safely).
3. When the air ionizer is operating, a green indicator light illuminates on 

the side of the radiator.
4. When the ionizer is switched off, the indicator light goes out.

* There is no ionizer in set of TOR ... RRX series. Please, note this.

Содержание TOR 21.1006 SLX I

Страница 1: ...31 2509 RRX TOR 31 3012 RRX Models Electric oil filled radiator Instruction manual TOR 21 SLX I TOR 31 RRX TOR 31 EHX I TOR 21 BTX I TOR 21 HBX I Outlook of devices aslo colour scores can be revised...

Страница 2: ...o 220Vsingle phasepowersupplywiringwithanearthcircuit Lines of Timberk electric oil filled radiators described in this operation manual TOR 31 EHX I features a built in fan heater TOR 31 RRX features...

Страница 3: ...l ENGLISH TOR 21 1206 BTX I TOR 21 1507 BTX I TOR 21 2009 BTX I TOR 21 2512 BTX I TOR 21 1206 HBX I TOR 21 1507 HBX I TOR 21 2009 HBX I TOR 21 2512 HBX I TOR 31 1706 RRX TOR 31 2007 RRX TOR 31 2509 RR...

Страница 4: ...veral months 14 Pay attention to the fact that the radiator is equipped with a European standard plug matching the standard European standard outlet The European standard plug of the power cord must g...

Страница 5: ...rn the thermostat knob counterclockwise Also you can lower the unit s operating power I or II 9 If you need to raise the room temperature turn the thermostat knob clockwise maximum possible position M...

Страница 6: ...ional 220V Timberk TOR 31 EHX I TOR 31 RRX TOR 21 BTX I TOR 21 HBX I TOR 21 SLX I 1 2 3 4 5 6 7 8 9 10 11 TOR 21 HBX I TOR 21 BTX I 1 4 2 3 7 8 5 1 TOR 21 EHX I TOR 21 RRX 9 6 6 3 4 7 2 10 11 5 1 2 3...

Страница 7: ...00 2000 2500 1200 1500 2000 2500 1700 2000 2500 3000 1700 2000 2500 3000 1000 1500 1800 2200 6 7 9 12 6 7 9 12 6 7 9 12 6 7 9 12 6 7 9 12 315x280x625 353x275x625 429x275x625 543x275x625 315x280x625 35...

Страница 8: ...8 www timberk com 1 2 3 4 5 6 7 8 Timberk TOR 31 RRX TOR 31 EHX I 9 10 11 OFF 12 13 14 180 Timberk www timberk com Timberk Timberk...

Страница 9: ...1 2 3 4 1 2 OFF 3 4 I II III 5 MIN c MAX 4 6 7 MIN 8 I II 9 MAX II III 10 Timberk TOR 31 RRX TOR 31 EHX I ON TOR RRX 9 www timberk com...

Страница 10: ...10 www timberk com OFF 1 100 2 3 4 5...

Страница 11: ...11 www timberk com EEC 89 336 Timberk Timberk RU 0001 11 71 123308 3 1 323 115162 28 4 7 495 6044266 7 495 6044266 P 52161 2 30 2007 P 51318 14 1 2006 4 P 51318 14 2 2006 p 5 7 P 51317 3 3 2008 P 513...

Страница 12: ...12 www timberk com Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS...

Страница 13: ...www timberk com 13...

Страница 14: ...14 www timberk com...

Страница 15: ...15 www timberk com...

Страница 16: ...www timberk com 71...

Отзывы: