www.timberk.com • electric humidifier
7
In case of emergency, please, use the troubleshooting methods shown in
tables. If it is impossible to solve problems with these methods, apply to
the service center.
11. TROUBLESHOOTING
Table 2
Problem
Possible cause
Remedy
Poor atomizing (insufficient
capacity)
The unit is operating in the minimized
mode (low atomizing frequency)
There is no problem. If you need to switch
to the intensive mode of operation, turn the
regulator handle all the way to the right.
The atomizer is clogged
Clean the atomizer.
Temperature of water in the tank is too low
Set maximum capacity. The humidifier’s
capacity will go up after a while.
No atomizing
The power cord is poorly connected
to the outlet
Connect the power cord into the outlet
carefully
There is white deposit on objects
around the humidifier (salts,
separating out from water)
1. Lime deposits have formed on the
membrane
2. There is a lot of salts in the water used
(calcium and magnesium)
1. Clean the humidifier’s membrane with a
special brush
2. Use filtered water
Steam has an unpleasant odor
Stale water is used
Clean the unit according to the cleaning
and servicing instructions and fill the tank
with fresh water
Remains of stale water or waste have
accumulated in the unit’s case or the
atomizer
Condensate is formed on the
upper part of the humidifier and
on surrounding objects, when it is
operating.
1. High humidification intensity is set.
2. High room humidity and temperature.
Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
Water appears next to the humidifier,
when it is operating.
1. High humidification intensity is set.
2. Lime deposits have formed on the
membrane and in grooves for water (in
the unit’s base).
1. Lower the humidification intensity by
turning the on/off and steam outflow
intensity regulator counterclockwise.
2. Clean the unit according to the cleaning
and servicing instructions.
Water appears next to the humidifier,
when it is not operating
Water tank is leaking
You need to contact an authorized service
center
Service life of the humidifier is 2 years.
At the end of its service life the humidifier should be utilized in accordance
with regulations and procedures, which are in force at the place of utilization.
12. DISPOSAL
10. TRANSPORTATION AND STORAGE
1. When transporting, any possible impacts and movements of the
package inside a vehicle must be avoided.
2. Handling symbols on the unit’s package must be strictly observed when
transporting and storing it.
3.
Temperature
requirements*
Humidity
requirements*
Transportation and
storage
-30°C to +50°C
15% to 85%
(no condensate)
We are researching new technologies and constantly improving the quality
of our products. Specifications, design and scope of delivery may be
changed without any prior notice.
* Products must be stored in dry, ventilated storages at the temperature not lower than -30°C.
IMPORTANT!
To avoid deformation or wear of working surfaces,
resulting in decreased atomizing or other malfunctions,
do not use metallic brushes, blades or talc powder
to wipe the atomizer’s surface. The water tank may
leak upon heavy impacts. In case of water leakage,
immediately stop using the unit and contact a service
center. To keep the unit dry, remove water after cleaning
and make sure to dry the unit’s case. Make sure that
there is no water left inside the unit’s case. Prior to a long
break in using the unit, dry its surface and pack it into
a plastic bag, then put it into a box. Store the unit in a
low-humidity room. Storing the unit undried results in
generation of mold.
•
Switch off the appliance and unplug it from the socket before cleaning it.
•
Clean the water tank and the base regularly. Use water only, no
detergents.
Always unplug the unit before removing the water tank. Do not touch the
water in the base during operation!
Содержание THU UL 16E
Страница 24: ...www timberk com ...