background image

 
IM2019

 

24 

 

COOLING 

or 

DEHUMIDIFYING/DRY modes. 

Strange noise 

This  noise  is  made  by  the 
expansion  or  contraction  of  the 
front panel due 

to  variations  in  temperature  and 
does not indicate a problem. 

 

Not a malfunction 

Insufficient 

hot 

or 

cold 

airflow 

 

Incorrect temperature setting. 

 

Set the correct 

air temperature

 

Air  inlet  or  outlet  of  indoor  or 
outdoor unit are blocked. 

Remove  foreign  objects  from 
inlet and outlet

 

Air filter is dirty. 

Clean the air filter 

Fan speed set at minimum. 

Increase the fan speed 

Other  sources  of  heat  in  the 
room. 

Remove  all  heat  sources 
from the room 

No refrigerant. 

Contact an authorized service 
center 

The  air  conditioner  is  not 
powerful enough for the room 

Use  the  device  in  an  area 
recommended 

by 

the 

manufacturer  (see  table  of 
technical specifications). 

Strong sunlight in the room 

Close the curtains 

Windows  and  /  or  doors  are 
open 

Close windows and / or doors 

The appliance does not 

respond to commands 

Remote  control  is  not  near 
enough to indoor unit. 

Use  the  remote  control  in 
close  proximity  to  the  device, 
directing it to the device 

Batteries  in  remote  control  are 
exhausted. 

Replace 

remote 

control 

batteries 

Obstacles 

between 

remote 

control  and  signal  receiver  in 
indoor unit. 

Use  the  remote  control  in 
close  proximity  to  the  device, 
directing it to the device

 

The display is off 

Active LED function 

Disable this function

 

Power failure 

Wait for power to recover

 

Switch off the air conditioner immediately and cut off the power supply in the event of:

 

Strange noises during operation.

 

Faulty electronic control board 

Faulty fuses or switches. 

Spraying water or objects inside the appliance. 

Overheated cables or plugs. 

Very strong smells coming from the appliance. 
 

*Electric air conditioners, split systems with a capacity of 7000, 9000, 12000, 18000 BTU are equipped with a 

Содержание T-AC07-S28-X

Страница 1: ...AIR CONDITIONER SPLIT SYSTEM INSTRUCTION MANUAL Models Indoor unit T AC07 S28 Y T AC09 S28 Y T AC12 S28 Y T AC18 S28 Y T AC24 S28 Y Outdoor unit T AC07 S28 X T AC09 S28 X T AC12 S28 X T AC18 S28 X T A...

Страница 2: ...DESCRIPTION 5 6 DELIVERY SET 5 7 SPECIFICATIONS 6 8 INSTALLATION OF THE DEVICE 7 9 DEVICE CONTROL 16 10 OPERATING MODES 19 11 MAINTENANCE 20 12 WIRING DIAGRAMS 21 13 TROUBLESHOOTING 23 14 UTILIZATION...

Страница 3: ...rst time check that the specifications on the product comply with the power supply specifications The appliance must be installed in accordance with the national electrical code Use the appliance only...

Страница 4: ...th foreign objects fingers only Keep the power cord away from sharp edges and hot surfaces If the product was at a temperature below 0 C for some time it must be kept at room temperature for at least...

Страница 5: ...reated air 6 Electric power network cord 7 Emergency shutdown button 8 Copper tube for gas refrigerant connection line 9 Tube for condensate removal 10 Air outlet grille of the outdoor unit 11 Power b...

Страница 6: ...ing heating 2 82 2 65 3 58 3 25 4 8 4 39 7 2 6 56 10 1 9 6 Air consumption indoor unit outdoor unit m 3 h 420 850 450 1000 550 1550 800 2200 1050 2700 Noise level indoor unit dB A 33 29 27 24 33 30 27...

Страница 7: ...45 280 970 380 305 970 380 305 Packing dimensions outdoor unit mm 760 470 345 760 470 345 780 550 345 920 605 395 945 435 725 8 INSTALLATION OF THE DEVICE Important Notices Before installing please co...

Страница 8: ...If the rated current of the device is greater than or equal to 16A it is necessary to use a connection to the mains with the organization of an individual line and install an ELCB For the connecting l...

Страница 9: ...ircuit poorly grounded to the earth The grounding wire is specially designed and shall not be used for other purpose nor shall it be fastened with a common tapping screw Others The model and rating va...

Страница 10: ...nd sealed with putty Note Usually the wall hole is 60mm 80mm Avoid pre buried power wire and hard wall when making the hole Fig 4 Route of Pipeline 1 Depending on the position of the unit the piping m...

Страница 11: ...en the Taper nut with a torque wrench and the direction is shown in diagram The torque used is shown in the following table Fig 7 Drain pipe connection 1 Put a corrugation to the output of the indoor...

Страница 12: ...ove the unit from left to right to ensure that the hook is properly positioned in the peg board 2 Push toward the lower left side and the upper right side of the unit toward the peg board until the ho...

Страница 13: ...IM2019 13 Fig 10 4 Put wiring cover back and then tighten the screw 5 Close the panel Fig 11 INSTALLATION OF OUTDOOR UNIT Dimension drawing of outdoor unit installation Fig 12...

Страница 14: ...ded 5 15M CC 12000Btu 20g m CC 18000Btu 30g m Note This table is for reference only Fig 13 Wiring Connection 1 Loosen the screws and remove E parts cover from the unit 2 Connect the cables respectivel...

Страница 15: ...lves and be sure to retighten it afterward to prevent the potential air leakage 1 To prevent air leakage and spilling tighten all connecting nut of all flare tubes 2 Connect the stop valve charge hose...

Страница 16: ...located behind the front panel For that open the front panel carefully by pulling it from the left and right Fig 17 Your device is equipped with a function for connecting an additional module for cont...

Страница 17: ...the scheme LOW MID HIGH AUTO Note AUTO air speed is not available in ventilation mode 4 5 Buttons Up Down The Up button 4 the temperature will rise by 1 C The Down button 5 the temperature will drop...

Страница 18: ...will display CL and the air conditioner will start the cleaning function This function gives opportunity to prevent fungus appearance and bad smell by drying moisture from evaporator using drying purg...

Страница 19: ...e ON OFF button again the air conditioner stops Note In the fan operation mode the temperature settings are non effective COOLING HEATING OPERATION MODE 1 Press the MODE button select the Cooling or H...

Страница 20: ...on for several hours in the FAN mode It will dry its inner cavities Unplug the conditioner Remove the batteries from the remote control Checks before starting Make sure that an air filter is installe...

Страница 21: ...IM2019 21 12 WIRING DIAGRAMS T AC07 S28 Y T AC09 S28 Y T AC12 S28 Y T AC18 S28 Y T AC24 S28 Y...

Страница 22: ...IM2019 22 T AC07 S28 X T AC09 S28 X T AC12 S28 X T AC18 S28 X T AC24 S28 X...

Страница 23: ...mes stops operating to protect the appliance Wait a little Voltage higher or lower than the voltage range Before using the device check whether the technical specifications indicated on the product co...

Страница 24: ...in the room Close the curtains Windows and or doors are open Close windows and or doors The appliance does not respond to commands Remote control is not near enough to indoor unit Use the remote contr...

Страница 25: ...the Seller must conform to the manufacturer s form The manufacturer and the authorized organization of the manufacturer remove responsibility for any possible harm which can be caused to people animal...

Страница 26: ...IM2019 26 1 2...

Страница 27: ...IM2019 27...

Страница 28: ...IM2019 28 0 C 2 7000 9000 12000 18000 BTU 24000 30000 36000 BTU 3 4 1 16 C 48 C 32 C 10 C 32 C 1...

Страница 29: ...IM2019 29 5 1 1 2 3 4 5 6 7 8 9 10 11 auto 12...

Страница 30: ...509 2325 2211 220 240 50 220 240 50 220 240 50 220 240 50 220 240 50 2 82 2 65 3 58 3 25 4 8 4 39 7 2 6 56 10 1 9 6 3 420 850 450 1000 550 1550 800 2200 1050 2700 33 29 27 24 33 30 27 24 36 33 30 27 3...

Страница 31: ...iba Toshiba Toshiba Hitachi Hitachi 4 15 1 15 4 15 1 15 4 15 1 15 4 15 1 15 4 15 1 15 8 8 5 9 11 12 20 21 25 37 39 9 5 10 10 5 13 14 22 23 27 5 40 43 690 283 199 690 283 199 750 285 200 900 310 225 90...

Страница 32: ...IM2019 32 4 16 1 5 2 2 1 5 H05VV F H07RN F H05RN F 2 3 6 0 75 6 10 1 00 10 16 1 50 16 25 2 50...

Страница 33: ...IM2019 33 2 I 2...

Страница 34: ...IM2019 34 1 2 3 3 4 3 5 10 4 4 60 80...

Страница 35: ...IM2019 35 5 6 5 6 1 2 7 7...

Страница 36: ...IM2019 36 1 2 3 1 2 3 8 1 2 9...

Страница 37: ...IM2019 37 1 ee 2 3 4 5 10 11 12...

Страница 38: ...IM2019 38 5 5 15 12000 BTU 20 18000 BTU 30 13 1 2 3 4 5...

Страница 39: ...IM2019 39 14 15 R410A 1 2 3 LO 15 0 1 76cmHg 4 5...

Страница 40: ...IM2019 40 16 9 on off 17 Wi Fi Wi Fi Wi Fi...

Страница 41: ...IM2019 41 18 1 Power 2 MODE AUTO COOL DRY HEAT FAN 3 SPEED LOW MID HIGH 4 5 4 1 5 1 16 60 F 32 C 90 F 6 SWING 7 SWING...

Страница 42: ...IM2019 42 8 TURBO 9 TIMER 10 iFAVOR 11 iFeel 12 HEALTH 13 SLEEP 2 10 14 iCLEAN CL iCLEAN 30 15 ANTI FUNGUS 16 DISPLAY...

Страница 43: ...IM2019 43 8 10 1 MODE 2 SPEED 3 ON OFF 4 ON OFF 1 MODE 2 16 C 32 C 3 SPEED 4 ON OFF 5 ON OFF 1 MODE 2 SPEED 3 ON OFF 4 ON OFF 1 MODE 2 ON OFF 3 ON OFF...

Страница 44: ...IM2019 44 10 11...

Страница 45: ...IM2019 45 12 T AC07 S28 Y T AC09 S28 Y T AC12 S28 Y T AC18 S28 Y T AC24 S28 Y...

Страница 46: ...IM2019 46 T AC07 S28 X T AC09 S28 X T AC12 S28 X T AC18 S28 X T AC24 S28 X...

Страница 47: ...IM2019 47 13...

Страница 48: ...IM2019 48...

Страница 49: ...IM2019 49 LIGHT 7000 9000 12000 18000 BTU 24000 30000 36000 BTU 14...

Страница 50: ...IM2019 50 15 30 C 50 C 15 85 5...

Страница 51: ...IM2019 51...

Страница 52: ......

Отзывы: