Timberk T-AC07-S27-X Скачать руководство пользователя страница 3

 

IM2019 

 

Dear customer! 

We thank you for your wise

 

choice and buying of a domestic air conditioner. It will serve you for 

a long time.

 

 

1. 

IMPORTANT INFORMATION 

 

The  appliance  is  designed  for  air  cooling,  heating,  dehumidifying,  ventilating

 

in  domestic 

premises.

 

The  manufacturer  reserves  the  right  to  make  minor  changes  to  the  design  of  the 

product  without  additional  notice  that  do  not  fundamentally  affect  its  safety,  performance  and 
functionality. There may be some misprints in text and digital notations in the present manual. In 
case after reading of this manual you have any questions concerning work and operation of the 
appliance,  please,  refer  to  a  shop  assistant  or  to  a  specialized  service  center  for  further 
explanations.  The  device  has  a  label  with  all  the  needed  technical  data  and  other  useful 
information  about  the  appliance.  Use  the  appliance  only  for  its  intended  purposes  indicated  in 
this manual. 

2. 

SAFEGUARDS 

 

When  using  an  electric  air  conditioner,  a  number  of  safety  precautions  must  be  observed. 
Improper operation by ignoring safety precautions can result in damage to the health of the user 
and other people, as well as damage to their property. 

 

Read these instructions carefully before using the appliance to avoid damage during use. 

 

Before starting up for the first time, check that the specifications on the product comply with 
the power supply specifications. 

 

The appliance must be installed in accordance with the national electrical code. 

 

Use the appliance only for the purpose specified in this manual. 

 

Do  not  use  the  indoor  unit  outdoors  or  in  high  humidity.  The  outdoor  unit  is  suitable  for 
outdoor use. 

 

Do not attempt to install the air conditioner by yourself. Consult a qualified installer. 

 

The  appliance  must  be  monitored  during  its  operation,  especially  if  there  are  children 
nearby. 

 

Do not push your fingers or objects through the exhaust grille of the indoor or outdoor units, 
as this may result in personal injury from a rotating fan. 

 

Do not allow children to turn on the air conditioner themselves. Children may only turn on 
air conditioning under adult supervision. 

 

Do not attempt to repair the air conditioner by yourself. The indoor and outdoor units of the 
air  conditioner  are  live,  it  is  life  threatening!  To  repair  the  product,  contact  an  authorized 
service center. 

 

Do not use the device if it is malfunctioning or if it has been dropped or damaged. 

 

Do not open the front panel of the device while it is in use. 

 

Do not disassemble or modify the device. 

 

Immediately disconnect the air conditioner from the mains if strange smell or smoke come 
from it. 

 

Do not spray or pour water or other liquids on the air conditioner. 

 

Always unplug the air conditioner during lightning storms. 

Содержание T-AC07-S27-X

Страница 1: ...AIR CONDITIONER SPLIT SYSTEM INSTRUCTION MANUAL Models Indoor unit T AC07 S27 Y T AC09 S27 Y T AC12 S27 Y T AC18 S27 Y T AC24 S27 Y Outdoor unit T AC07 S27 X T AC09 S27 X T AC12 S27 X T AC18 S27 X T A...

Страница 2: ...SCRIPTION 5 6 DELIVERY SET 6 7 SPECIFICATIONS 6 8 INSTALLATION OF THE DEVICE 7 9 DEVICE CONTROL 17 10 OPERATING MODES 19 11 MAINTENANCE 20 12 WIRING DIAGRAMS 21 13 TROUBLESHOOTING 23 14 UTILIZATION RU...

Страница 3: ...efore starting up for the first time check that the specifications on the product comply with the power supply specifications The appliance must be installed in accordance with the national electrical...

Страница 4: ...ons on the remote control with foreign objects fingers only Keep the power cord away from sharp edges and hot surfaces If the product was at a temperature below 0 C for some time it must be kept at ro...

Страница 5: ...intake grille 2 Front panel 3 Air filter 4 5 Blinds deflectors for distribution of treated air 6 Electric power network cord 7 Emergency shutdown button 8 Copper tube for gas refrigerant connection li...

Страница 6: ...12897 3780 20329 5958 26293 7706 Rated power consumption cooling heating W 650 610 825 748 1106 1011 1656 1509 2325 2211 Power supply V Hz 220 240 50 220 240 50 220 240 50 220 240 50 220 240 50 Rated...

Страница 7: ...4 15 1 15 Net weight indoor unit kg 8 8 5 9 11 12 Net weight outdoor unit kg 20 21 25 37 39 Gross weight indoor unit kg 9 5 10 10 5 13 14 Gross weight outdoor unit kg 22 23 27 5 40 43 Net dimensions i...

Страница 8: ...eas rustproofed The mounting rack and its load carry surface shall be able to withstand 4 times or above the weight of the unit The mounting rack of the outdoor unit shall be fastened with expansion b...

Страница 9: ...ng out installation at 2 m or higher above the base level safety belts must be worn and ropes of sufficient strength be securely fastened to the outdoor unit to prevent falling that could cause person...

Страница 10: ...the lateral horizontal and longitudinal vertical 3 Pull the peg board by hand after the installation to confirm whether it is solid Fig 3 Wall through hole 1 Make a hole with an electric hammer or a w...

Страница 11: ...Fig 6 depending on the pipe length of the indoor unit In the case of sideway routing cut off the outlet cutting stock of the opposite side 2 The power cable may be routed separately from the piping C...

Страница 12: ...r outlet The drain hose must not have bends twists bends etc The end of the drain hose shouldn t touch water Wrap the Piping 1 Use the insulation sleeve to wrap the joint part the indoor unit and the...

Страница 13: ...nection cord installation Connect interconnection cord of indoor unit 1 Open the panel remove the screw on the wiring cover and then take down the cover 2 Make the interconnection cord go through the...

Страница 14: ...ing pipe at the stop valve and tighten the Taper nut with fingers Then tighten the Taper nut with a torque wrench When prolonging the piping extra amount of refrigerant must be added so that the opera...

Страница 15: ...utdoor unit see the wiring diagram and if there are signals connected to the plug just conduct butt joint 3 Ground wire Remove the grounding screw out of the electric bracket cover the grounding wire...

Страница 16: ...d be sure to retighten it afterward to prevent the potential air leakage 1 To prevent air leakage and spilling tighten all connecting nut of all flare tubes 2 Connect the stop valve charge hose manifo...

Страница 17: ...ntrol panel Description of indoor unit control panel In case the remote control is lost or cannot be used at the moment you may use a control button on off located behind the front panel For that open...

Страница 18: ...OR Return the device to the user s previous personal settings option is not supplied in this model 11 iFeel Click this button to display temperature settings in the control panel for a comfortable tem...

Страница 19: ...erating commands from the remote control point an IR emitter at a remote control signal receiver situated on the indoor unit Hold the remote control board at the distance of no more than 8 m from the...

Страница 20: ...an be turned on by pressing any button for the convenience of operation in darkness The backlight will be automatically turned off if there is no operation within 10 seconds 11 MAINTENANCE Before clea...

Страница 21: ...s installed in a room with dusty atmosphere then the air filter should be cleaned more often To remove the filter open the indoor unit panel Remove air filters Clean the filter with a vacuum cleaner I...

Страница 22: ...IM2019 22 T AC24 S27 Y T AC07 S27 X T AC09 S27 X T AC12 S27 X T AC18 S27 X...

Страница 23: ...g pulled out Wait for restoration of power supply plug in the device Damaged indoor outdoor unit fan motor Contact an authorized service center Faulty compressor thermomagnetic circuit breaker Contact...

Страница 24: ...comes from the air outlet This occurs when the air in the room becomes very cold for example in the COOLING or DEHUMIDIFYING DRY modes Not a malfunction Strange noise This noise is made by the expans...

Страница 25: ...time of the device expires it should be recycled in compliance with the laws rules and methods in region of recycling Detailed information about the recycling of the device you can receive from a repr...

Страница 26: ...ould be transported vertical Temperature Requirements Transportation and storage From 30 C up to 50 C Humidity Requirements From 15 up to 85 without a condensate We are exploring new technologies and...

Страница 27: ...IM2019 27 1 2...

Страница 28: ...IM2019 28...

Страница 29: ...IM2019 29 0 C 2 7000 9000 12000 18000 BTU 24000 30000 36000 BTU 3 4 1 16 C 48 C 32 C 10 C 32 C 1...

Страница 30: ...IM2019 30 5 1 1 2 3 4 5 6 7 8 9 10 11 auto 12...

Страница 31: ...650 610 825 748 1106 1011 1656 1509 2325 2211 220 240 50 220 240 50 220 240 50 220 240 50 220 240 50 2 82 2 65 3 58 3 25 4 8 4 39 7 2 6 56 10 1 9 6 3 420 850 450 1000 550 1550 800 2200 1050 2700 33 2...

Страница 32: ...35 29 46 343 420 593 923 1211 Toshiba Toshiba Toshiba Hitachi Hitachi 4 15 1 15 4 15 1 15 4 15 1 15 4 15 1 15 4 15 1 15 8 8 5 9 11 12 20 21 25 37 39 9 5 10 10 5 13 14 22 23 27 5 40 43 690 283 199 690...

Страница 33: ...IM2019 33 4 16 1 5 2 2 1 5 H05VV F H07RN F H05RN F...

Страница 34: ...IM2019 34 2 3 6 0 75 6 10 1 00 10 16 1 50 16 25 2 50 2 I...

Страница 35: ...IM2019 35 2 1 2 3 3 4 3...

Страница 36: ...IM2019 36 5 10 4 4 60 80 5 6 5...

Страница 37: ...IM2019 37 6 1 2 7 7 1 2 3 1 2 3...

Страница 38: ...IM2019 38 8 1 2 9 1 ee 2 3 4 5...

Страница 39: ...IM2019 39 10 11 12...

Страница 40: ...IM2019 40 5 5 15 12000 BTU 20 18000 BTU 30 13 1 2 3 4 5 14...

Страница 41: ...IM2019 41 15 R410A 1 2 3 LO 15 0 1 76cmHg 4 5 16...

Страница 42: ...IM2019 42 9 on off 17 19...

Страница 43: ...IM2019 43 1 Power 2 MODE AUTO COOL DRY HEAT FAN 3 SPEED LOW MID HIGH 4 5 4 1 5 1 16 60 F 32 C 90 F 6 SWING 7 SWING 8 TURBO 9 TIMER 10 iFAVOR 11 iFeel 12 HEALTH 13 SLEEP 2...

Страница 44: ...IM2019 44 10 14 iCLEAN CL iCLEAN 30 15 ANTI FUNGUS 16 DISPLAY 8 10 1 MODE 2 SPEED 3 ON OFF 4 ON OFF...

Страница 45: ...IM2019 45 1 MODE 2 16 C 32 C 3 SPEED 4 ON OFF 5 ON OFF 1 MODE 2 SPEED 3 ON OFF 4 ON OFF 1 MODE 2 ON OFF 3 ON OFF 10 11...

Страница 46: ...IM2019 46...

Страница 47: ...IM2019 47 12 T AC07 S27 Y T AC09 S27 Y T AC12 S27 Y T AC18 S27 Y T AC24 S27 Y...

Страница 48: ...IM2019 48 T AC07 S27 X T AC09 S27 X T AC12 S27 X T AC18 S27 X T AC24 S27 X...

Страница 49: ...IM2019 49 13...

Страница 50: ...IM2019 50...

Страница 51: ...IM2019 51 LIGHT 7000 9000 12000 18000 BTU 24000 30000 36000 BTU 14...

Страница 52: ...IM2019 52 15 30 C 50 C 15 85 5...

Страница 53: ...IM2019 53...

Страница 54: ...IM2019 54...

Страница 55: ......

Страница 56: ......

Отзывы: