background image

www.timberk.com • electrical storage water heater

www.timberk.com • electrical storage water heater

15

14

water temperature in the water heater reaches the temperature, set by the 

user, the heating is automatically switched off, at that “      ” indicator light on 

the control panel lights down. When water temperature in the water heater 

drops  to  a  certain  level,  the  heating  is  automatically  switched  off,  at  that             

“         ” indicator light on the control panel lights up.

3. Power mode selection

3.1. Press the thermostat knob several times to select the desired heating 

power.
3.2. If you select low heating power then “energy save” indicators light up 

on the control panel and “       ” indicator is shown on the display.
3.3. If you select medium heating power then “normal heat” indicators light 

up on the control panel and “            ” indicator is shown on the display
.3.4 If you select high heating power then “energy save” and “normal heat” 

indicators light up on the control panel simultaneously, and “         ” indicator 

is shown on the display.
3.5. After the heating mode is selected, “energy save” and “normal heat” 

indicators are on for 10 minutes, then they light down.

4. Clock setting

4.1. When the water heater is on, press “mode” button once, and clock 

value will start blinking on the display.
4.2. Press “           ” button to increase hours, in increments of 1 hour for 

single pressing.
4.3. Press “      ” button to increase minutes, in increments of 1 minute for 

single pressing.
4.4. When the desired time will be set, do not press any buttons, the clock 

will keep blinking for 5 seconds and then setting will be completed and the 

clock will start counting.

5. Timer setting

5.1. Water heater activation timer setting

IMPORTANT! 

Water may start dripping from the relief valve hole 

during heating. It is impossible to avoid water leakage 

and you must not prevent it since valve blocking 

may cause rupture of the internal tank (in case of 

equipment failure).

5.1.1. When the water heater is on, press “mode” button twice and the 

clock [00:00] on the display will start blinking.
5.1.2. Using buttons “      ” and “       ” set the desired water heater activation 

time (see item 4.2, 4.3).
5.1.3. . When the desired time will be set, do not press any buttons, the 

clock will keep blinking for 5 seconds and then setting will be completed.
5.2. Water heater deactivation timer setting
5.2.1. When the water heater is on, press “mode” button three times and 

the clock [00:00] on the display will start blinking.
5.2.2. Using buttons “      ” and “      ” set the desired water heater 

deactivation time (see item 4.2, 4.3).
5.2.3. When the desired time will be set, do not press any buttons, the 

clock will keep blinking for 5 seconds and then setting will be completed.
5.3. Timer activation
When the water heater is on, press “timer” button once and “       ” indicator 

will light up on the display and “TIMER” word will light up under the clock, 

after that the water heater on/off timer will be activated, and heating will be 

switched off (if it was on).
5.4. Timer deactivation
Press “timer” button 3 times, “       ” indicator and “TIMER” under the clock 

will light down, after that the water heater on/off timer will be deactivated.

6. Night heating

When this function is activated, water heating will be performed only at 

night, from 23:00 to 06:00. Heating will be impossible during other hours.
6.1. Press “timer” button twice to activate night heating, at that “   ” 

indicator on the display will light up.
6.2. Press “timer” button twice again to deactivate night heating, at that 
“        ” indicator on the display will light down.

7. Timer and night heating

Timer and night heating can be activated simultaneously. For this purpose 

it is necessary to press “timer” button several times until timer and night 

heating indicators light up simultaneously.

8. Control panel locking

8.1. Press and hold “mode” button on the control panel of the water heater 

for 3 seconds to lock control buttons, at that “       ” indicator on the display 

will be shown.

You can also use special button on remote control.

8.2. Press and hold “mode” button on the control panel of the water heater 

for 3 seconds again to unlock control buttons, at that “        ” indicator on 

the display will light down.

9. Switching off

Press the temperature controller handle and hold it for several seconds or 

press “ON/OFF” button on the remote controller to switch off the appliance, 

at that indicator lights will light down and the temperature controller handle 

back lighting will stay on.

9. MAINTENCE

Fig. 13

Fig. 14

Fig. 15

1. Check the power plug and outlet as often as possible. Secure electrical 

contact and also proper grounding must be provided. The plug and outlet 

must not heat excessively.
2. If the water heater is not used for a long time, especially in regions with 

low air temperature (below 0°C), it is necessary to drain water from the 

heater .
3. To ensure long reliable water heater operation, it is recommended to 

regularly clean the internal tank and remove deposits on the electric heating 

element of the water heater, as well as check condition of the magnesium 

anode and, if necessary, replace it with a new one.

4. Preventive operations must be performed upon strict observance of the 

operation manual and safety precautions.
5. The water heater is equipped with a thermal switch, which cuts off power 

supply of the heating element upon water overheating or its absence in the 

water heater. If the water heater is connected to the mains, but water is 

not heated and the indicator doesn’t light up, then the thermal switch was 

switched off or not switched on. To reset the water heater to the operating 

condition, it is necessary to:
- de-energize the water heater, remove the plate of the side / lower cover 

for horizontal-type/vertical-type water heater respectively. 
- for FSM6/FSM4 series horizontal-type water heaters: press the button, 

located in the center of the thermal switch, placed near the heating element 

(with a round shape), until it clicks, Fig.14;
- for FSM5/FSM3 series vertical-type water heaters: unscrew retaining 

nut of the thermal switch, fastened on the flange of the heating element, 

turn the thermal switch and press the button, located in the center of the 

thermal switch, until it clicks; Fig. 15;
- if the button is not pressed and there is no clicking, then you should wait 

until the thermal switch cools down to the initial temperature.

IMPORTANT! 

The manufacturer provides an extended guarantee 

for particular water heater components provided that 

timely and proper routine maintenance is performed 

by specialists of an authorized service center (see the 

guarantee card).

IMPORTANT! 

If these actions had no positive result or the thermal 

switch turns off repeatedly during a short period of 

time, then you should de-energize the water heater, 

cut off water supply and contact your local Timberk 

Authorized Service Center for a consult or repair of the 

appliance.

Содержание SWH FSM3 100 V

Страница 1: ... H SWH FSM6 80 H SWH FSM6 100 H SWH FSM3 30 V SWH FSM3 50 V SWH FSM3 80 V SWH FSM3 100 V SWH FSM4 30 H SWH FSM4 50 H SWH FSM4 80 H SWH FSM4 100 H Electrical storage water heater Outlook of devices aslo colour scores can be revised without any special advance notices Производитель вправе менять внешний вид прибора и цветовую гамму при бора без специального уведомления FSM5 FSM6 FSM3 FSM4 ...

Страница 2: ...ons may harm health of the user and other people as well as damage their property 1 Any electrical appliance must be supervised when in operation espe cially if there are children nearby Make sure children do not touch the ap pliance 2 Prior to installing the water heater not connecting it to electrical main check and make sure the outlet for the water heater has a ground pin and if it is properly...

Страница 3: ...7 8 7 8 7 8 7 Rated power W 2000 2000 2000 2000 Stage power W 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Tank capacity L 30 50 80 100 Rated pressure Mpa 0 7 0 7 0 7 0 7 Water protection class IPX4 IPX4 IPX4 IPX4 Heating time at Δ 30 ºC min 28 46 73 80 Appliance dimensions mm 550x435x238 855x435x238 991x493x270 1190x493x270 Weight kg 9 8 13 4 18 9 23 4 Factual year energy consumption k...

Страница 4: ... 5 heating element 6 right composite protective cover 7 temperature sensor case 8 composite pressure safety valve be sure to install onto the cold water supply tube Pos A 9 emergency discharge of surplus water pressure a small water leakage is possible from the emergency discharge hole when the water heater is operating It is normal 10 inlet nozzle with a splitter 11 hot water outlet nozzle 12 eme...

Страница 5: ...umber of consumption points to the outlet nozzle marked red 7 Check leak integrity of joints open the shut off cock and one of the cock assemblies After the tank is filled with water as evidenced by issue of water from the cock assembly shut the cock assembly and check the leak integrity of all joints Connection to water main 1 The heater must be connected to water main with at least 0 1 MPa press...

Страница 6: ... connected to the outlet Do it in the following order insert the power plug into the outlet switch off the water heater after half hour operation and unplug the cord check if the plug is heated by your hand If the plug is heated over 50 C then to prevent damages accidents and fire as a result of bad electrical contact replace the outlet with a new one A specialist must do this 3 Power cord of the ...

Страница 7: ... used to activate timer and night heating 8 button It is used to increase the selected value 9 MODE button It is used to set time and timer 1 Time indication 2 Timer activation indicator It lights up when water heater on off timer is activated 3 Energy save indicators They light up when selecting low heating power 800 W 4 Water heater water temperature indicator 5 Mode button It is used to set tim...

Страница 8: ...night heating at that indicator on the display will light up 6 2 Press timer button twice again to deactivate night heating at that indicator on the display will light down 7 Timer and night heating Timer and night heating can be activated simultaneously For this purpose it is necessary to press timer button several times until timer and night heating indicators light up simultaneously 8 Control p...

Страница 9: ...h Water temperature control system is damaged Contact a repairer TIMBERK service center Water leakage Seal at the point of pipe connection is broken Replace the joint seal Water flows from the appliance s case Breaking of the internal tank corrosion Seal at the point of the heating element connection is broken Contact a repairer TIMBERK service center Failure Cause Troubleshooting method E1 Dry he...

Страница 10: ...нтура в вашей электросети эксплуатация водонагревателя опас на для жизни 3 Подключайте водонагреватель только к сети 230В 50Гц При не обходимости выясните характеристики своей сети у поставщиков электроэнергии 4 Во избежание перегрева и риска возникновения пожара а также повреждения внутренней электрической сети не изменяйте длину сетевого шнура и не подключайте водонагреватель через электри чески...

Страница 11: ...0 230 50 Номинальная сила тока A 8 7 8 7 8 7 8 7 Номинальная потребляемая мощность Вт 2000 2000 2000 2000 Мощность по ступеням Вт 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Объем л 30 50 80 100 Номинальное давление МПа 0 7 0 7 0 7 0 7 Класс влаго защиты IPX4 IPX4 IPX4 IPX4 Класс защиты I I I I Время нарева при Δ 30 ºC мин 28 46 73 80 Размеры прибора мм 550x435x238 855x435x238 991x493x...

Страница 12: ...лектрический водонагреватель следует устанавливать на прочной стене 2 Стена на которой устанавливается электрический водонагрева тель должна выдерживать как минимум двойной вес водонагрева теля полностью заполненного водой на стене должны отсутствовать трещины и другие повреждения В противном случае необходимо при нять меры для усиления крепления или установить водонагреватель на специальной опоре...

Страница 13: ...керные болты следует преду смотреть свободное пространство между нижней частью водонагревателя и полом не менее 0 6 м а для серии FSM6 FSM4 ещё и свободное про странство между боковой крышкой с правой стороны и стеной для обеспечения удобства тех нического обслуживания при необходимости его проведения Монтаж водонагревателя 1 Электрический водонагреватель следует устанавливать на проч ной стене Ес...

Страница 14: ...роверку проводите в следующем порядке вставьте электрическую вилку в розетку через полчаса работы выключите водонагреватель и вынь ВНИМАНИЕ Перед подключением накопительного водона гревателя убедитесь в том что водонагреватель заземлен надлежащим образом Правильное за земление важно для минимизации ударов током и опасности возгорания Шнур питания оснащён вилкой с контактом заземления Устройство до...

Страница 15: ...ньшаете температуру нагрева воды 3 4 Водонагреватель автоматически поддерживает температуры воды Когда температура воды внутри водонагревателя достигает установленной пользователем температуры нагрев автоматически выключается при этом на панели управления светится только инди катор питания голубого цвета Когда температура воды внутри водонагревателя понижается ниже установленного уровня нагрев авт...

Страница 16: ...лятора против часовой стрелки от по зиции max к позиции min или нажмите кнопку чтобы умень 3 Выбор режима мощности 3 1 Нажмите на ручку терморегулятора на панели управления несколь ко раз или на соответствующие кнопки на ПДУ чтобы выбрать необхо димую мощность нагрева 3 2 При выборе низкой мощности нагрева на панели управления за гораются индикаторы energy save а на дисплее отображается инди катор...

Страница 17: ...тся рядом с ТЭНом имеет круглую форму рис 14 для вертикальных водонагревателей серии FSM5 FSM3 нажать до щелчка кнопку расположенную по центру термовыключателя рис 15 если кнопка не нажимается и нет щелчка то подождать пока термо 6 Чтобы правильно слить воду из внутреннего бака надо восполь зоваться сливным отверстием только для серии FSM6 FSM4 надо открутить заглушку закрывающую сливное отверстие...

Страница 18: ...ие электросхемы изделия которое может быть выполнено без уведомления потребителя По окончании срока службы водонагреватель следует утилизировать Подробную информацию по утилизации водонагревателя Вы можете получить у представителя местного органа власти Срок службы во донагревателя составляет 15 лет 13 УТИЛИЗАЦИЯ Серийный номер изделия месяц и год изготовления указаны в со ставе ID LINE кода издел...

Страница 19: ...ей техники Timberk мы дополнительно сообщаем что русский является государствен ным языком в следующих госу дарствах в Российской Федерации в Республике Беларусь наряду с белорусским языком в частично признанной Южной Осетии наряду с осетинским языком Русский язык является офици альным языком во всех случаях другой язык или другие языки выступают как государствен ный или второй официальный в следую...

Страница 20: ...рический накопительный водонагреватель 39 38 Если вы заметили ошибку в руководстве пожалуйста сообщите нам об этом связавшись с нами по электронной почте указанной на сайте www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com ...

Страница 21: ...www timberk com ...

Отзывы: