ENGLISH

7

Fig

. 4

Fig

. 5

PROPER ASSEMBLY

IMPROPER ASSEMBLY

Make sure that the water heater is operable passing water flow through it. 
Check  tightness  of  all  connections  and,  if  necessary,  tighten  nuts  and 
mounting screws including screws in flanges of the heating vessel.

NOTE

:

Before installation of the water heater, flush water pipes with flowing 

water.

ATTENTION

!

It is prohibited to use the water heater without reliable grounding.

Connection to electric mains

1. The power cord is led in through the side face of the appliance.It is pro-
hibited to use a plug socket for connection of the water heater to the elec-
tric mains, except for WHN-4 OS, WHP-4 OS models.
2. The water heater shall be connected to the 220VAC electric mains with a 
three-core  copper  electric  cable  having  the  following  minimum  wire 
section:for WHN-4 OS, WHP-4 OS models - 3x1.5 mm2 and a 16A circuit 
breaker; for WHN-5 OS, WHP-5 OS models - 3x2.5 mm2 and a 25A circuit 
breaker.It  is  necessary  to  increase  wire  section,  if  the  water  heater  and 

4. For connection of power supply:
- Remove the front panel;
- Strip off insulation of the power wires to length not less than 7-10 mm and 
strip off insulation of the grounding wire to length not less than 2-2.5 mm;
- Lead the electric cable through the side face in the rear panel of the appli-
ance enclosure cutting the electric cable gland at the center with a sharp 
knife;
- Remove the clamping plate of the electric cable keeping the installation 
screws and make sure that the cable does not cross sharp edges and does 
not contact with hot surfaces;
- Connect the electric cable wires with the terminal block according to the 
appliance marking (refer to Fig.6);
- Make sure that all clamping screws of the terminal block are secured.A 
loose connection may result in heating of wires;
- Install the clamping plate of the electric cable to the main position using 
the installation screws and make sure that the power cord cannot be re-
moved;
-  Check  connection  tightness  of  all  internal  electric  contacts  including 
removable  contact  groups  and  bolt  contact  connections  on  heating 
elements.If there are loose connections, they shall be fixed and tightened;
- Install the front panel.

~220 

VAC

To grounding loop

Fig

. 6

www.timberk.com

   

i

nstant 

water heater

ATTENTION

!

When the water heater is operated in particularly difficult (includ-

ing obsolete) water pipeline systems with a large quantity of sus-

pended  particles  and  impurities  in  flowing  water,  application  of 

purification filters at the inlet of the water heater is OBLIGATORY.

Use  this  recommendation;  otherwise,  non-fulfilment  of  this  item  may 
affect service life of the product and warranty service conditions (up to 
refusal of warranty liabilities by the product manufacturer and manufac-
turer's service departments). 

electric cable itself are located on a thermally insulated or heating wall.
3. The  water  heater  shall  be  connected  to  the  220VAC  power  supply 
source permanently (except for WHN-4 OS, WHP-4 OS) with obligatory 
connection to the electric grounding loop. Make sure that resistance of 
the grounding loop is < 4 .

Содержание HP-5 OS

Страница 1: ... Models Instant water heater Instruction manual Outlook of devices aslo colour scores can be revised without any special advance notices WHN 4 OS WHN 5 OS WHP 4 OS WHP 5 OS Evolution 4 ...

Страница 2: ... disconnect it from the electric mains Perform cleaning and mainte nanceinaccordancewiththeguidelinesofthisinstructionmanual 9 Do not use hazardous chemicals for cleaning of the water heater and excludetheircontactwithit 10 Do not use the water heater for purposes not specified in this instruc tionmanual CONTENTS 1 Importantinformation 2 Precautions 3 Performancedata 4 Waterheaterdesign 5 Packagec...

Страница 3: ...tric wires of the device to a water pipeline a gas pipeline etc 24 Make sure in proper connection of electric wiring including connec tiontothegroundingloop 25 Inlettemperatureofwatershallnotexceed 35 C 26 Foruseofthewaterheaterinabathroom itisrecommendedtoinstall itabovebodyheightsothatwatersplashesdonotgetontoitsenclosure 27 Itisprohibitedtosplashwaterontotheheaterorirrigateit 28 ItisPROHIBITEDt...

Страница 4: ...t of measure V kW P L min mm kg WHN 4 OS WHP 4 OS shower 220 50 16 3 5 0 03 0 60 2 5 IPX4 I 16 382x250x91 400x260x100 1 8 2 1 WHN 5 OS WHP 5 OS shower 220 50 21 4 5 0 03 0 60 3 2 IPX4 I 21 382x250x91 400x260x10 1 8 2 1 Table1 Specifications SpecificationsofthewaterheateraregiveninTable1 4 WATER HEATER DESIGN The water heater design by the example of WHN series is shown in Fig 1 www timberk com ins...

Страница 5: ...tercanbeinstalledinanyplaceprovidedthattemperature intheroomisnotbelow0 C 2 The water heater is installed onto flat wall surface so that water and splashescannotgetontoitsenclosure 3 During selection of a location for the water heater it is necessary to ensure free access to it on the basis of not less than 0 3 m from above from below and sideways This will ensure the maximum comfort of maintenanc...

Страница 6: ... sure in the mains exceeds 0 6 MPa the feed system shall be fitted with a reduction valve pressure reducer so that operating pressure does not exceed0 6MPa The water feed shutoff valve shall be installed upstream of the water heaterinlet Fig 4 Installationofashutoffvalveatthehotwateroutletfromthewaterheater isprohibited Fig 5 After installation of the water heater and before connection of power su...

Страница 7: ...allation screws and make sure that the cable does not cross sharp edges and does notcontactwithhotsurfaces Connect the electric cable wires with the terminal block according to the appliancemarking refertoFig 6 Make sure that all clamping screws of the terminal block are secured A looseconnectionmayresultinheatingofwires Install the clamping plate of the electric cable to the main position using t...

Страница 8: ...ill make a self test for 2 sec and ifthereisnocurrentleakage theE SAFEandEARTHindicatorswilllightup onthecontrolpanel 3 Turn the power control knob Figs 7 8 clockwise The POWER indicator will light up provided that water flow rate exceeds 2 4 L min and the wa terheaterwillstartwaterheating 4 To check the water heater for current leakage push the TEST button when the water heater is working in the ...

Страница 9: ... cold The heating indicator Power continues glowing while the water inlet valve is closed The indicators extinguish upon pushing the TEST button the indicators do not light up upon pushing the RESET button Possible causes 1 There is no power supply 2 The temperature limiter at 95 C is tripped or not activated 3 The printed board is faulty 4 Current leakage 1 Water flow rate is less than 2 4 L min ...

Страница 10: ...ngdisposalofthewaterheater pleasecontactarepre sentativeofthelocalauthorities Servicelifeofadeviceis5years 10 ELECTRICALSCHEMATICDIAGRAM Fig 9 Terminal block Blue Braun Yellow Green Temperature limiter 95 C Heating element Silicon control unit Water ow sensor Temperature limiter 55 C Indication board RCD Control board Transformer board 10 ...

Страница 11: ...11 www timberk com 2 1 2 3 220 50 4 5 6 7 1 2 3 4 5 6 7 8 9 10 11 12 Timberk 0 TIMBERK 1 11 11 12 14 14 15 17 19 19 20 20 20 ...

Страница 12: ...12 www timberk com 8 9 10 11 12 13 14 15 16 17 18 19 20 21 28 3 1 2 3 55 95 IN OUT 22 23 24 25 35 26 27 ...

Страница 13: ...4 OS 220 50 16 3 5 0 03 0 60 2 5 IPX4 I 16 382x250x91 400x260x100 1 8 2 1 WHN 5 OS WHP 5 OS 220 50 21 4 5 0 03 0 60 3 2 IPX4 I 21 382x250x91 400x260x100 1 8 2 1 1 1 4 2 4 5 1000 3500 WHN 4 OS WHP 4 OS 1000 4500 WHN 5OS WHP 5OS 6 7 TIMBERK ...

Страница 14: ...www timberk com 14 www timberk com 4 WHN 1 5 2 1 1 1 1 1 1 1 1 1 WHN 4 OS WHP 4 OS WHN 5 OS WHP 5 OS 2 1 ...

Страница 15: ...www timberk com 15 www timberk com 3 3 2 6 1 0 2 3 0 3 4 1 6 5 2 0 03 0 6 0 6 0 6 4 5 3 ...

Страница 16: ...4 7 10 2 2 5 G1 2 450 CaCO3 4 1 WHN 4OS WHP 4OS 2 220 WHN 4 OS WHP 4 OS 3x1 5 2 16 WHN 5OS WHP 5OS3x2 5 2 25 3 WHN 4 OS WHP 4 OS 220 4 5 www timberk com 16 ...

Страница 17: ...7 WHN 4 OS WHN 5 OS 220 В к контуру заземления 6 6 1 TEST 2 RESET 3 4 POWER 5 Electricitycheck 5 4 3 2 17 www timberk com Рис 7 1 ...

Страница 18: ...AFE EARTH 3 7 8 POWER 2 4 4 TEST Electricitycheck POWER WHN E SAFE EARTH POWER WHP WHP 4 OS WHP 5 OS Рис 8 1 TEST 2 RESET 3 ON OFF 4 5 POWER 6 E SAFE 7 EARTH RESET RESET 7 5 15 5 7 8 3 20 WHN 4 OS WHP 4 OS 3 5 16 18 6 7 6 5 4 3 2 1 www timberk com 6 ...

Страница 19: ...9 3 8 Power Power TEST RESET 1 2 95 3 4 1 2 4 2 3 55 4 1 2 1 2 1 2 95 3 4 Timberk 1 2 3 55 4 1 2 1 2 Timberk Timberk 19 www timberk com ...

Страница 20: ...23308 3 1 323 115162 28 4 74956044266 74956044266 P 60335 2 35 2000 P51318 14 1 2006 4 P51318 14 2 2006p 5 7 P51317 3 3 2008 P51317 3 2 2006p 6 7 RUC IL AB71 B 00051 09 02 2012 08 02 2015 www timberk com 10 88000 972 8 637 88 311 1 1 606 499 638 26 77 7 495 6275285 ...

Страница 21: ...Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS 21 ...

Страница 22: ...22 ...

Страница 23: ...23 www timberk com ...

Страница 24: ...www timberk com 71 ...

Отзывы: