Timberk AC TIM 07H S26 Скачать руководство пользователя страница 10

www.timberk.com • electric air conditioner

10

• Before a sustained interruption in the conditioner work:
• Turn the conditioner on for several hours in the FAN 

mode. It will allow you to dry its inner cavities

• Unplug the conditioner. Remove the batteries from the 

remote control board. 

Checks before starting:

•  Make sure that an air filter is installed.
• Make sure that air inlet and outlet grilles of the outdoor 

unit are not blocked by foreign objects.

Cleaning of air filter

• Air filter cleans the air entering the conditioner from dust 

and foreign particles. If the filter is contaminated, the 

conditioner capacity decreases sharply.

• If the conditioner is operated permanently, the filter 

should be cleaned once per two weeks.

• If the conditioner is installed in a room with dusty atmo-

sphere, then the air filter should be cleaned more often.

• To remove the filter, open the indoor unit panel.
• Remove air filters. Clean the filter with a vacuum cleaner. 

If the filter is contaminated heavily, clean it with a soft 

brush and wash in diluted washing solution, then dry it 

in a cool place.

• While cleaning the filter with the vacuum cleaner, hold it 

with contaminated surface up. While washing the filter in 

water, hold it with contaminated surface down.

• Do not dry the filter in the sun or near a fire.
• Set the air filter to initial position and close the panel.

9. TROUBLESHOOTING

In case of emergency, please, use the troubleshooting 

methods shown in tables. If it is impossible to solve 

problems with these methods, apply to the service center.
Failures and their possible reasons:

Failure

Possible reason

Actions

The conditioner 

does not work

Interruptions in power 

supply

Wait for restoration of 

power supply

Batteries in the remote 

control board are low

Replace the batteries

Time of tuming on is 

set by the timer

Wait till the 

conditooner turns on 

by the timer or cancel 

the timer setting

Insufficient 

cooling or heating 

capacity

The set air temperature 

is too high or too low

Set the air temperature 

correctly

The air filter is clogged 

with dust

Clean the air filter

Foreign objects block 

the air intel and retum 

air grillages of the 

outdoor unit

Remove foreign 

objects

The conditioner 

works, but does 

not cool or heat 

the room

A three-minute delay of 

compressor tuming on

Wait a little

The air temperature is 

set incorrectly

Set the temperature 

correctly

Содержание AC TIM 07H S26

Страница 1: ...09H S26 AC TIM 12H S26 AC TIM 18H S26 AC TIM 24H S26 outdoor unit AC TIM 07H S26 O1 AC TIM 09H S26 O1 AC TIM 12H S26 O1 AC TIM 18H S26 O1 AC TIM 24H S26 O1 INSTRUCTION MANUAL Outlook of devices also...

Страница 2: ...tic premises The manufacturer reserves the right to intro duce changes in design configuration and process ing of the article with a view to improve its properties without any prior notification of cu...

Страница 3: ...ditioner during a lighting storm 13 Always unplug the conditioner when it is not used 14 Before cleaning and maintenance of the conditioner unplug it Cleaning and maintenance should be performed in ac...

Страница 4: ...ply V Hz 220 240 50 220 240 50 220 240 50 220 240 50 220 240 50 Rated power current cooling heating 2 82 2 65 3 58 3 25 4 8 4 39 7 2 6 56 10 1 9 6 Air circulation indoor unit m3 h 420 450 550 800 1050...

Страница 5: ...e range cooling C 16 48 16 48 16 48 16 48 16 48 Operating temperature range heating C 10 32 10 32 10 32 10 32 10 32 Filling of refrigerant g 400 540 610 1000 1560 Net weight indoor unit kg 8 8 5 9 11...

Страница 6: ...or indoor installation 1 piece Conditioner unit for outdoor installation 1 piece Remote control board 1 piece Batteries for remote control board 2 pcs User manual 1 piece Batteries for remote control...

Страница 7: ...f remote control board Fig 3 Your device is equipped with a function for connecting an additional module for controlling the air conditioner via Wi Fi Wi Fi control works only after connecting an addi...

Страница 8: ...ime expires the device will return to automatic mode The speed of fan also gets lower so the noise level decreases too 14 iCLEAN This function gives opportunity to prevent fun gus appearance by drying...

Страница 9: ...e allows changing threshold of switching from mode to mode During operation in Smart mode you see on the display Press keys Temp will change by 2 The range shift of this threshold is within 2 2 of def...

Страница 10: ...While cleaning the filter with the vacuum cleaner hold it with contaminated surface up While washing the filter in water hold it with contaminated surface down Do not dry the filter in the sun or near...

Страница 11: ...re is shown in a serial number of the device For more details please ask a shop assistant We are exploring new technologies and we constantly im proving the quality of our products That s why specific...

Страница 12: ...www timberk com 12 1 2 3 4 5 6 7 8 9 10 11 TIMBERK 1 12 13 14 16 16 16 19 20 21 22 22 23 23 24 35...

Страница 13: ...www timberk com 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2...

Страница 14: ...TIM 18H S26 O1 AC TIM 24H S26 AC TIM 24H S26 AC TIM 24H S26 O1 2100 2650 3550 5300 7000 2200 2700 3650 5450 7100 650 825 1106 1656 2325 610 748 1011 1509 2211 220 240 50 220 240 50 220 240 50 220 240...

Страница 15: ...ss I class IPX0 IPX0 IPX0 IPX0 IPX0 IPX4 IPX4 IPX4 IPX4 IPX4 1 4 3 8 1 4 3 8 1 4 3 8 1 4 1 2 3 8 5 8 10 10 12 15 18 8 8 8 10 13 16 48 16 48 16 48 16 48 16 48 10 32 10 32 10 32 10 32 10 32 400 540 610...

Страница 16: ...www timberk com 16 1 4 1 2 3 4 5 6 1 1 2 1 3 1 4 2 5 1 6 1 7 1 5 7 8 9 10 11 auto 12 6 8 9 10 1 2 3 4 5 6 7 11 12...

Страница 17: ...www timberk com 17 2 on off 3 1 Power 2 MODE AUTO COOL DRY HEAT FAN Wi Fi Wi Fi Wi Fi 3 7 10 13 16 4 2 6 8 15 14 11 12 9 5 1...

Страница 18: ...ww timberk com 18 3 SPEED LOW MID HIGH 4 5 4 1 5 1 16 60 F 32 C 90 F 6 SWING 7 SWING SWING 8 TURBO 9 TIMER 10 iFAVOR 11 iFEEL 12 HEALTH 13 SLEEP 2 10 14 iCLEAN iCLEAN 30 15 ANTI FUNGUS 16 DISPLAY LR03...

Страница 19: ...www timberk com 19 7 1 MODE 2 SPEED 3 ON OFF 4 ON OFF 1 MODE 2 16 C 32 C 3 SPEED 4 ON OFF 5 ON OFF 1 MODE 2 SPEED 3 ON OFF 4 ON OFF 1 MODE 2 ON OFF 2 ON OFF 8...

Страница 20: ...www timberk com 20 Anti Fungus 8 10...

Страница 21: ...www timberk com 21 9 10...

Страница 22: ...www timberk com 22 30 50 15 85 1 2 3 30 11 89 336 801 24 26 Home Electronics Limited 801 Luk Yu Building 24 26 Stanley Street Central China 119361 2 5 125195 57 12 7 495 627 52 85 Serial number...

Страница 23: ...www timberk com 23 Production date 004 2011 768 16 2011 020 2011 879 9 2011 RU C CN 53 01923 25 10 2018 24 10 2019 ______________________...

Страница 24: ...www timberk com 24 30 TIMBERK TIMBERK 45 TIMBERK TIMBERK www timberk com 7 495 627 52 85 www timberk com ru service timberk com TIMBERK 10...

Страница 25: ...www timberk com 25 1 c Timberk 29 TIMBERK 2 TIMBERK 3...

Страница 26: ...www timberk com 26 www timberk com TIMBERK TIMBERK...

Страница 27: ...www timberk com 27 171 21 12 2004 18 5...

Страница 28: ...www timberk com 28 TIMBERK...

Страница 29: ...www timberk com 29 1 2 3 1 Timberk Timberk Timberk www timberk com Timberk 25 502 11 19 01 1998 55...

Страница 30: ...www timberk com 30 30 1 2 3 10 4 5 __________________________________ _____________________ ______________________________...

Страница 31: ...www timberk com 31...

Страница 32: ...www timberk com 32...

Страница 33: ...www timberk com 33...

Страница 34: ...www timberk com 34...

Страница 35: ...www timberk com 35...

Страница 36: ...TIMBERK c 10 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com www timberk com Timberk...

Отзывы: