TILO Color Assessment Cabinet
User Manual (version 2016)
www.hcl-asia.com.hk
Page 3 of 5
HCL Asia Ltd | Edited 25 May 2022
be used to add UV to D65 light source.
7. Shop light source. Various clients often require other light source for color
check. For example, US clients prefer using CWF whereas European and
Japan clients prefer using TL84. It is because the goods are being displayed
and sold indoor and are under the shop light source and not under outdoor sun
light. It becomes more and more popular to use shop light source for checking
color.
III.
Operation Instructions
1. Plug one end of power cable into socket at the backside of the lamp cabinet and
the other end into electric supply source (electric supply must comply with
nominal electricity of the cabinet.) After connecting the power, the display will
be lit to indicate that the power is on.
2. Press "ON/OFF" power switch once and the number of use and time will be
displayed.
3. Press D65 switch again and D65 lamp will be lit up. The number of use and time
will be displayed for D65 lamp. Pressing F, TL84 or UV switch, the
corresponding lamps will be lit up and the number of use and time will be
displayed accordingly. In case of need of using two or more light sources,
simply press two or more lamp switches as desired.
4. Put the articles to be checked at the center of the bottom of the lamp cabinet.
When comparing the color of two or more articles, do not observe them by
overlapping, instead, put them in the cabinet side by side.
5. It is recommended to assess the goods as Figure I. When the light ray is
reaching on the goods from top to down, the inspector should assess the goods
in 45 degree of angle.
6. After use, press ON/OFF switch to power off. Switch off the power of the lamp
cabinet if it will not be used for a long time.
7.
Install new lamp as Figure II and read the instructions with care. Do not mix up
the lamps’ position.
Note:
After replacing, it is important to
RESET
the number
of use and time to [ZERO] for a new lamp as below procedures:
press the new
lamp switch, insert a small screw driver or a pin to the central hole of CLR switch
and press, at the same time, the switch of the newly replaced lamp, the number
of use and time will be reset to zero as a new start. Note: Do not press CLR key
in case of not replacing lamp to avoid resetting data unwantedly.