be used to add UV to D65 light source. 

7.  Shop light source.  Various clients often require other light source for color 

check.  For example, US clients prefer using CWF whereas European and 

Japan clients prefer using TL84. It is because the goods are being displayed 

and sold indoor and are under the shop light source and not under outdoor sun 

light.    It becomes more and more popular to use shop light source for checking 

color. 

 

III. 

Operation Instructions

 

1.  Plug one end of power cable into socket at the backside of the lamp cabinet and 

the other end into electric supply source (electric supply must comply with 

nominal electricity of the cabinet.)  After connecting the power, the display will 

be lit to indicate that the power is on. 

2.  Press "ON/OFF" power switch once and the number of use and time will be 

displayed. 

3.  Press D65 switch again and D65 lamp will be lit up. The number of use and time 

will be displayed for D65 lamp.  Pressing F, TL84 or UV switch, the 

corresponding lamps will be lit up and the number of use and time will be 

displayed accordingly.  In case of need of using two or more light sources, 

simply press two or more lamp switches as desired. 

4.  Put the articles to be checked at the center of the bottom of the lamp cabinet.   

When comparing the color of two or more articles, do not observe them by 

overlapping, instead, put them in the cabinet side by side. 

5.  It is recommended to assess the goods as Figure I.  When the light ray is 

reaching on the goods from top to down, the inspector should assess the goods 

in 45 degree of angle. 

6.  After use, press ON/OFF switch to power off.    Switch off the power of the lamp 

cabinet if it will not be used for a long time. 

7. 

Install new lamp as Figure II and read the instructions with care. Do not mix up 

the lamps’ position.   

Note: 

After replacing, it is important to 

RESET

 the number 

of use and time to [ZERO] for a new lamp as below procedures: 

press the new 

lamp switch, insert a small screw driver or a pin to the central hole of CLR switch 

and press, at the same time, the switch of the newly replaced lamp, the number 

of use and time will be reset to zero as a new start. Note: Do not press CLR key 

in case of not replacing lamp to avoid resetting data unwantedly. 

 

 

 

 

 

 

 

 

 

 