background image

Maintenance Schedule  

Remember that this schedule is based on the assumption that your machine will be used for its 
designed purpose. Sustained high-load or high-temperature operation, or use in unusually wet or 
dusty conditions, will require more frequent service.  
 

REGULAR SERVICE PERIOD (1) 

 
 
 

Before 

Each Use 

 
 

First 

Month or 

20 Hours 

 
 

Every 3 

Months or 

50 Hours 

 
 

Every 6 

Months or 
100 Hours 

 

Every 

year or 

300 

Hours 

ITEM 
Performed at every indicated month or 
operating hour interval, whichever 
comes first 

 

Engine Oil 

Check 

 

 

 

 

 

Change 

 

 

 

 

 

 

Air filter 

Check 

 

 

 

 

 

Change 

 

 

 (2)

 

 

 

 

Sediment Cup 

Clean 

 

 

 

 

 

 

Spark Plug 

Check 

 

 

 

 

 

Change 

 

 

 

 

 

 

Spark Arrester 

Clean 

 

 

 

 

 

 

Idle Speed 

Check-Adjust 

 

 

 

 

 

 

Valve Clearance 

Check-Adjust 

 

 

 

 

 

 

Combustion 
Chamber 

Clean 

After every 500 hours 

 

Fuel tank and filter 

Clean 

 

 

 

 

 

 

Fuel Tube 

Check 

Every 2 years (replace if necessary) 

 
(1) For commercial use, log hours of operation to determine proper maintenance intervals. 
(2) Service more frequently when used in dusty areas.  
 

Engine Oil Change  

Drain the oil while the engine is warm to assure rapid and complete draining.  

 

Remove the drain plug and sealing washer, remove the oil filler cap and drain the oil.   

 

Reinstall the drain plug and sealing washer. Tighten the plug securely.   

 

Refill with the recommended oil and check the oil level 

 

Wash your hands with soap and water after handling used oil.   

 

 

 

23 

Содержание TPP-4500DF-A

Страница 1: ...ow all safety rules and instructions in this manual before attempting to operate this machine Failure to comply with these instructions may result in personal injury Diagrams within this manual may no...

Страница 2: ...GENERATOR 19 STOPPING THE GENERATOR 20 OPERATION INSTRUCTIONS 20 MAINTENANCE 22 STORAGE 26 INSTALLATION 26 TROUBLESHOOTING 28 WIRING DIAGRAM 29 MODEL SPECIFICATIONS 30 The engine exhaust from this pr...

Страница 3: ...injury Read them carefully Please read the manual and pay attention to these sections Save These Important Safety Instructions Read and understand all of these safety instructions Be sure to retain th...

Страница 4: ...PMENT WHEN USING AIR TOOLS BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY Specific Warnings Carbon Monoxide When this tool is running ensure that the area is...

Страница 5: ...EL OR OTHER FLAMMABE MATERIALS NEAR THE GENERATOR Do not smoke or allow sparks flames or other sources of ignition around the engine and fuel tank Fuel vapors are explosive Keep grounded conductive ob...

Страница 6: ...damaged power cords immediately Damaged power cords increase the risk of electric shock When operating a power tool outside use an outdoor extension cord marked W A or W These extension cords are rate...

Страница 7: ...ed or corroded Keep terminals clean and tight Power Output This generator is not designed to power sensitive electronic equipment such as computers mobile phones medical devices and the like without t...

Страница 8: ...s hardhat or hearing protection must be used for appropriate conditions Do not force the generator Use the correct generator for your application The correct generator will do the job better and safer...

Страница 9: ...THIS PRODUCT ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE INTERFERENCE TO OR FAILURE OF THE PACEMAKER Installation Ensure installation meets all applicable safety local...

Страница 10: ...oisture within the generator s area Mechanical Always make sure the power switch is in its OFF position Disconnect the spark plug wire and allow the engine to completely cool before carrying out maint...

Страница 11: ...ting or working around the generator when it is running Additional Safety Information Operator Responsibility Know how to stop the generator quickly in case of emergency See page 20 Understand the use...

Страница 12: ...for a while after stopping the engine Be careful not to touch the muffler while it is hot Let the engine cool before storing the generator indoors Gasoline is extremely flammable and is explosive unde...

Страница 13: ...GENERATOR COMPONENTS See next page for further explanations 13...

Страница 14: ...ting the engine by recoil starter set the key switch to the ON position and pull the recoil starter handle Gasoline Fuel Valve The gasoline fuel valve is located between the fuel tank and carburetor W...

Страница 15: ...he engine the engine switch will remain in the ON position The Oil Alert system should not take the place of checking the oil level before each use If the engine stops and will not restart check the e...

Страница 16: ...800 1300 Kitchen Microwave Oven 1000 watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500 Pe...

Страница 17: ...ick and then screw the dipstick back into the oil fill hole FILL OIL ON A LEVEL SURFACE Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped o Remove the oi...

Страница 18: ...Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified to operate on unleaded gasoline Unleaded gasoline produces fewer engine and spark p...

Страница 19: ...T HOLD FOR MORE THAN 5 SECONDS If the engine fails to start release the switch and wait 10 seconds before operating the starter again NOTE If the speed of the starter motor drops after a period of tim...

Страница 20: ...urn the fuel valve lever to the OFF position OPERATING INSTRUCTIONS Connections to a Building Electrical System Connections for standby power to a building electrical system must be made by a qualifie...

Страница 21: ...S LLC NOR ITS AFFILIATES ARE RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY THE FAILURE TO USE AN APPROVED LINE CONDITIONER CAUTION Substantial overloading will open the circuit breaker Excee...

Страница 22: ...When the carburetor has been modified for high altitude operation the air fuel mixture will be too lean for low altitude use Operation at altitudes below 5 000 feet 1 500 meters with a modified carbur...

Страница 23: ...diment Cup Clean Spark Plug Check Change Spark Arrester Clean Idle Speed Check Adjust Valve Clearance Check Adjust Combustion Chamber Clean After every 500 hours Fuel tank and filter Clean Fuel Tube C...

Страница 24: ...lean engine oil and squeeze out the excess oil The engine will smoke during initial startup if too much oil is left in the air filter element Reinstall the air filter element and the cover Never run t...

Страница 25: ...s the washer Caution The spark plug must be securely tightened An improperly tightened spark plug can become very hot and could damage the engine Never use spark plugs which have an improper heat rang...

Страница 26: ...o the table below STORAGE TIME RECOMMENDED SERVICE PROCEDURE Less than 1 month No preparation required 1 to 2 months Fill with fresh gasoline and add gasoline conditioner 2 months to 1 year Fill with...

Страница 27: ...it Generator placement should allow four feet of access to all sides for maintenance Place the generator as close as possible to the electrical tools and equipment being powered to reduce the length o...

Страница 28: ...ck the oil level Add oil if necessary Damaged Spark Plug Remove and check that the spark plug is in good condition Replace if necessary Carburetor needs to be choked Rotate the choke lever to fully cl...

Страница 29: ...29...

Страница 30: ...al Drop Dual Drop Dual Drop Dual Drop Dual Drop Electrical Automatic Voltage Regulation Yes Yes Yes Yes Yes Battery Maintenance Free Maintenance Free Maintenance Free Maintenance Free Maintenance Free...

Отзывы: