2.2.5
Remove/Replace Crystal Filter Board, p/n 923069 or Jumper Board, p/n 923074
REMOVAL
(1)
Remove dust cover of unit as described in Paragraph 2.2.1.
(2)
Remove and retain the four screws securing the crystal filter board, p/n 923069-1 (or
jumper Board, p/n 923074) to the standoffs on the external frequency set module A5A1.
Pull the crystal filter board assembly straight up to avoid damaging the connector pins.
REPLACEMENT
(1)
Align the pins on the bottom of the crystal filter board with their sockets on the memory
set board. Push the crystal filter board straight down until it rests on the memory set
board standoffs and secure with the four mounting screws.
(2)
Connect Module A5A1 co-axial jumper leads to jumper J2/P3 on Rx/Tx Module A1, if not
already connected. Either a crystal filter board, p/n 923074 or a jumper board, p/n
923074 must be installed and the A5A1 co-axial jumper leads connected to J2/P3 on the
Rx/Tx Module A1, for the receiver to work.
NOTE:
Make certain that the memory set board, module A5A1 is programmed to the same
operating frequency as the crystal filter board assembly. If no crystal filter board assembly
(option) is installed, jumper board assembly P/N 923074-1 must be installed.
2.3 CHANNEL
FREQUENCY
SELECTION
Early radios have their frequencies programmed by a diode matrix as
described in Section 2.3.3. For radio units shipped after July 2012 and
equipped with a USB port, please refer to Appendix A (TiL TDP-90
Programming Software User’s Guide for USB Programmable AM Series
Transceivers) - Document 11RE439.
2.3.1 Introduction
Before programming a new operating frequency, verify operation on the original frequency.
2.3.2 Frequency
Range
The operating frequency may be programmed over the frequency range 117.975 MHz to 138.000
MHz with 25 kHz channel spacing.
2.3.3
Pre-programming Channel Frequency
FREQUENCY SELECTION MHz.
Refer to Table 2.1 Frequency Selection MHz. Using the OPERATING FREQUENCY (MHz)
column, find the desired frequency in MHz. Cross-refer to the JUMPER LOCATION column, and
install the jumper as required.
FREQUENCY SELECTION KHz
Refer to Table 2.2, Frequency Selection kHz. Using the OPERATING FREQUENCY kHz column,
find the portion of the desired frequency in kHz. Cross-refer to the JUMPER LOCATION column,
and install the jumpers in the locations as required.