SW-H411A
HDMI 2.0 4x1 Presentation Switcher with
Audio Extraction
All Rights Reserved
Version: SW-H411A_2020V1.0
Страница 1: ...SW H411A HDMI 2 0 4x1 Presentation Switcher with Audio Extraction All Rights Reserved Version SW H411A_2020V1 0...
Страница 2: ...t details FCC Statement This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio c...
Страница 3: ...to rain moisture or install this product near water Do not put any heavy items on the extension cable in case of extrusion Do not remove the housing of the device as opening or removing housing may e...
Страница 4: ...onnection 6 5 Button Control 7 5 1 Manual Switching 7 5 2 Automatic Switching 7 5 3 Display Control 7 5 4 EDID Setting 8 6 IR Remote Control 9 7 GUI Control 10 7 1 Switching Tab 11 7 2 Display Control...
Страница 5: ...ital audio output and a balanced analog audio output The switcher features multiple methods of control When in the AUTO mode the switcher will automatically switch to the first detected source device...
Страница 6: ...IR Remote 1x 3 pin Terminal Block 1x 5 pin Terminal Block 1x RS232 Cable 3 pin terminal block to DB9 1x Power Adapter 12V DC 1A 1x User Manual 1 3 Customer Service We provide limited warranty for the...
Страница 7: ...Connector 1 Toslink connector 1 5 pin terminal block HDMI Audio Format LPCM 7 1 audio Dolby Atmos Dolby TrueHD Dolby Digital Plus DTS X and DTS HD Master Audio pass through Stereo analog L R audio For...
Страница 8: ...5mm mini jack 1 3 pin terminal block 1 RJ45 General HDMI 2 0 Cable Length 4K 60Hz 4 4 4 5m 4K 60Hz 4 2 0 10m 1080P 15m Bandwidth 18Gbps Operation Temperature 10 55 Storage Temperature 25 70 Relative...
Страница 9: ...TROL Press ON to turn on the display Press OFF to turn off the display Press to mute unmute display audio Press to decrease the audio volume gradually or press and hold it to decrease the audio volume...
Страница 10: ...balanced audio output EDID 4 pin DIP switch for EDID setting IR IN Connects to IR receiver to control the switcher by the included IR remote RS232 Connects to RS232 control device PC or a device to b...
Страница 11: ...w input Reboot If power is restored to the switcher it will automatically reconnect the input before powered off Source removed When an active source is removed the switcher will switch to the first a...
Страница 12: ...d it represents 1 while putting the switch in the upper ON position Switch Status Video Resolution Audio Format 0000 Default EDID pass through 0001 1920x1080 60Hz RGB 4 4 4 8bit Stereo Audio 0010 1920...
Страница 13: ...r can be controlled by the below IR remote Enter or exit standby mode Video input selection buttons 1 4 and AUTO mode button Source device control buttons Page Up Page Down Rewind Fast Forward Pause P...
Страница 14: ...IP and the default static IP setting is IP Address 192 168 0 178 Subnet Mask 255 255 255 0 Please type 192 168 0 178 in the internet browser and it will enter the below log in webpage Username admin P...
Страница 15: ...0 4x1 Presentation Switcher with Audio Extraction 11 7 1 Switching Tab Click the AUTO button to enable automatic switching mode Click 1 4 button to select input source respectively 7 2 Display Contro...
Страница 16: ...with Audio Extraction 12 ON Display On OFF Display Off Mute unmute display audio Volume down display audio Volume up display audio 7 3 Audio Tab Turn on or turn off the digital audio output Turn on o...
Страница 17: ...ition Built in EDID There are ten built in EDID values can be selected by this tab User defined EDID There are four EDID values can be customized by the below steps Step 1 Prepare the EDID file bin on...
Страница 18: ...on 14 7 5 RS232 Tab Baud Rate Supports 2400 4800 9600 19200 38400 57600 or 115200 Command Ending NULL CR LF or CR LF can be chosen Command Type the command in this box to control the third party devic...
Страница 19: ...HDMI 2 0 4x1 Presentation Switcher with Audio Extraction 15 7 6 Interface Tab Modify the title bar label and button labels 7 7 Access Tab...
Страница 20: ...front panel buttons 7 8 Network Tab Set Static IP or Dynamic Host Configuration Protocol DHCP The default IP mode is DHCP press and hold Volume Up and Volume Down buttons for 3 sec to enable Static IP...
Страница 21: ...ype the username and password the same as the GUI log in setting modified password will be available only after rebooting to login the configuration interface After that click Administration in the so...
Страница 22: ...are able to send command in command sending area Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none 8 2 TCP IP Control The system can be controlled over a network connection A TCP IP communication...
Страница 23: ...nel Locked UNLOCK Unlock front panel buttons Front Panel UnLock RST Factory reset Factory Default STA Report system status SW H411A V1 0 0 POWON Front Panel UnLock Local RS232 Baudrate Is 9600 GUI IP...
Страница 24: ...passoff Disable audio bypass ByPass off GETGUIIP Report GUI IP GUI_IP 192 168 0 178 SetGuiIP_DHCPON Set the IP mode to DHCP GUI IP DHCP ON SetGuiIP_DHCPOFF x xx xxx xxx xxx Set GUI IP to xxx xxx xxx x...
Страница 25: ...19200 9600 4800 or 2400 Baudrate9600 Set Local RS232 Baudrate Is 9600 X xxx Send the command xxx to control the third device e g Projector xxx ASCII string The X represents the baud rate of third par...
Страница 26: ...x to the third party device whose baud rate is X X Baud Rate X Baud Rate 1 2400 2 4800 3 9600 4 19200 5 38400 6 57600 7 115200 The Y can be 0 or 1 If the Y is 0 clear the saved command xxx If the Y is...
Страница 27: ...ect a U disk named of BOOTDISK 4 Double click the U disk a file named of READY TXT would be showed 5 Directly copy the latest upgrade file bin to the BOOTDISK U disk 6 Reopen the U disk to check the f...