STEP 1:
Remove the two fixing bolts from the fixture as shown in Figure 7,
then take out the slip fitter.
Slip fitter
Screws
STEP 2:
Rotate the slip fitter as shown in Figure 8 and slide the slip-fitter
back into position,
use 25 n.m torque to tighten the screws.
Pole-arm(Horozontal Tenon)Mounting
Pole Top Mounting
-5
°
+
15
°
+
15
°
-5
°
Adjustable Slip Fitter from Pole-Arm mounting to Pole-Top Mounting Steps
9
5
Photocell
PHOTOELECTRIC CONTROLLER INSTALLATION (OPTIONAL)
STEP A: Make sure a NEMA receptacle on top of fixture is available.
STEP B: Find out the size difference of three pins on P.E.C.U., the
size difference of three slots on NEMA receptacle.
STEP C: Insert P.E.C.U. in receptacle, and twist it clockwise
firmly.See Figure7.
PRECAUTIONS:
If the above receptacle is unscrewed, please be sure to note
that the receptacle screw torque
of 1.0 to 2.0 N-m is recommended. Do NOT exceed 3.0 N-m.
Install photocontrol or shor ting plug , Downlight only.
This logo indicates that this product must not be disposed of with other waste.
Please recycle used lamps to prevent environmental hazard and threats to human
health resulting from improper disposal.
Rev. Date: V1 08/11/2020
www.tigerlight.com.au
The instruction is for reference only. All rights reser ved by
Please visit our website www.tigerlight.com.au and download the electronic
version of instruction and specification sheet if needed.
Tiger Light Pty Ltd.
WIRING INSTRUCTION
STEP I: Connect the L1 wire in the mains power supply cord to the “L1”
marked hole In the terminal block and tighten the connection
properly.
STEP II: Connect the L2 wire in the mains power supply cord
to the “L2” marked hole in the terminal block and tighten the
connection properly.
STEP III: Connect the Earth wire in the mains power supply cord
to the “ ” marked hole in the terminal block and tighten the
connection properly.
6
Electrical Connections
Terminal Block
L1
L2
L1
Earth
L2
L1-Brown
Earth
L2-Blue