2. SPECIFICATIONS
2.1 GENERAL SPECIFICATIONS
Maximum Capacity
Single Range Mode:-
Max = 1 ~ 999,999 (kg or lb)
Dual Range Mode: -
Max
1
= 1 ~ 999,998( kg or lb)
Max
2
= 2 ~ 999,999( kg or lb)
External Resolution
Single Range Mode:-
Recommend = 15,000 ~ 30,000
High = 30,000 ~ 60,000
Dual Range Mode: -
Recommend (Max
2
/ d
1
) = 15,000 ~ 30,000
High (Max
2
/ d
1
) = 30,000 ~ 60,000
Weight Units
Metric (kg) and Imperial (lb),g,oz
Min. Internal Count/d
15 Count
Offset Range
≥
0.2mv (10000 Count)
Tare Range
- Max (Subtractive Tare)
Max. Measuring Range
15 mV
A/D Sampling Speed
15 times/ second
Power Voltage
Requirements
Built-in Rechargeable Battery = 6V DC
External Power Adaptor = 12V DC, 800mA
Load Cell Excitation
Voltage
5 VDC
Minimum/Maximum
Load Cell Impedance
350
Ω
/1000
Ω
Load Cell Connection
Supports 4-wire and 6-wire Load Cell
Connections
Maximum Load Cell
Connection
8 x 350
Ω
Load Cells, or
16 x 700
Ω
Load Cells
Operation Environment
-10 ~ 40
o
C. Non-condensed. R.H.
≦
85%
Specifications subject to change prior to notice