TIFFIN MOTORHOMES
–PHAETON®
Chapter 4
MAJOR APPLIANCES & ACCESSORIES
> Check flame site hole to see if igniter is sparking from the probe to the burner. Bend ignition wire to adjust to
proper gap or contact the manufacturer or the nearest authorized service representative.
There is no ignition. Red LED is flashing a series of seven flashes.
The ignition has locked out. Check for these possible causes:
> Locate the high temperature switch (two light blue wires) at the upper right hand of the heat exchanger.
Push the reset button in the center of the switch. (Early models only; newer models have an auto reset).
> Check that the yellow ignition wire is clipped to the spark electrode terminal and is not touching anything else.
Check that there are no cuts or breaks in the yellow wire. Align it so that it is not in contact with anything
but the terminal.
> Excessively high or turbulent winds may cause the burner to extinguish. Adjust the position of the vehicle
relative to the prevailing wind.
Heater turns on but temperature fluctuates erratically.
> Hot and cold water lines are reversed on back of heater. If the flow meter rotor is not rotating counterclockwise,
pipes are connected in reverse. Be sure hot water is connected to bottom fitting and cold to the top fitting.
> May be caused by excessive restriction at the water outlets, showerheads, aerators or water strainers.
These should be cleaned and the showerhead flow restrictor removed as defined in “Recommendations for
Water System Installation.”
> The Variflame gas modulating valve is out of calibration. Consult the manufacturer. Heater does not ignite
when water is turned on.
> The gas flow may be too low due to an improper gas line diameter (under 3/8” outside diameter). The gas line
may be excessively long (over 20 feet) or the on/off solenoid at the tank (if you have one) may have an orifice
that is too small (under 3/16” of an inch).
Heater comes on but rapidly cycles on and off.
> Water flow is too low. Increase flow at a tap. Clean all aerators and shower head screens.
> Water pump is not functioning properly. Repair or replace pump.
> If the heater cycles as the pump cycles, a pressure accumulator tank is needed in the water system. If you have
an accumulator tank, check to see if it has become filled with water. If it has, drain it so that it contains air only.
> Air is in the water line. Bleed air by turning on all water taps.
4-13
Содержание 2014 Phaeton
Страница 6: ... TIFFIN MOTORHOMES PHAETON Chapter 1 GENERAL INFORMATION GENERAL INFORMATION 1 1 ...
Страница 13: ... TIFFIN MOTORHOMES PHAETON Chapter 1 DRIVING SAFETY INSTRUCTIONS DRIVING SAFETY INSTRUCTIONS 2 1 ...
Страница 25: ... TIFFIN MOTORHOMES PHAETON Chapter 3 HEATING AIR CONDITIONING HEATING AIR CONDITIONING 2 1 ...
Страница 31: ... TIFFIN MOTORHOMES PHAETON Chapter 4 MAJOR APPLIANCES ACCESSORIES MAJOR APPLIANCES ACCESSORIES 4 1 ...
Страница 56: ... TIFFIN MOTORHOMES PHAETON Chapter 5 CABINETS FURNITURE CABINETS FURNITURE 5 1 ...
Страница 60: ... TIFFIN MOTORHOMES PHAETON Chapter 6 STRUCTURAL FEATURES STRUCTURAL FEATURES 6 1 ...
Страница 62: ... TIFFIN MOTORHOMES PHAETON Chapter 7 ELECTRICAL FEATURES ELECTRICAL FEATURES 7 1 ...
Страница 74: ... TIFFIN MOTORHOMES PHAETON Chapter 8 SLIDE OUT FEATURES SLIDE OUT FEATURES 8 1 ...
Страница 78: ... TIFFIN MOTORHOMES PHAETON Chapter 9 EXTERIOR FEATURES EXTERIOR FEATURES 9 1 ...
Страница 85: ... TIFFIN MOTORHOMES PHAETON Chapter 10 INTERIOR FEATURES INTERIOR FEATURES 10 1 ...
Страница 88: ... TIFFIN MOTORHOMES PHAETON Chapter 11 PLUMBING BATH FIXTURES PLUMBING BATH FIXTURES 11 1 ...
Страница 99: ... TIFFIN MOTORHOMES PHAETON Chapter 12 WINDOWS AWNINGS VENTS DOORS WINDOWS AWNINGS VENTS DOORS 12 1 ...
Страница 104: ... TIFFIN MOTORHOMES PHAETON Chapter 13 ROUTINE MAINTENANCE ROUTINE MAINTENANCE 13 1 ...
Страница 142: ... TIFFIN MOTORHOMES PHAETON Chapter 14 MAINTENANCE DATA CHARTS MAINTENANCE DATA CHARTS 14 1 ...