Home Automation Area
ENABLE/DISABLE ANTI-FROST
It is possible to enable/disable the anti-frost protection function by entering the
INFO
mode (by keeping the
IP
button pressed for at least 3 seconds) and by accessing the
<NOFR*>
menu (by pushing the
OK
button in
quick succession). A value equal to 1 indicates the function is enabled, whereas a value equal to 0 indicates
the function is disabled. By using the
UP
and
DOWN
buttons it is possible to modify that value.
0
2
15
1
2
8
1
1
9
3
6
ENABLE/DISABLE ROOM TEMPERATURE SENSOR
It is possible to enable/disable the room temperature sensor function by entering into
INFO
mode (by
keeping pushed the
IP
button for at least 3 seconds) and by accessing the
<AMBON>
menu (by pushing the
OK
button in quick succession). A value equal to 1 indicates the enabled function, whereas a value equal to
0 indicates a disabled function. By using the
UP
and
DOWN
buttons it is possible to modify that value. By
disabling the room temperature sensor the system will work at a constant level (non-fluctuating) according to
the set programmed parameters.
PUSH THE
IP
BUTTON AND KEEP
IT PUSHED FOR 3 SECONDS TO
ENTER INTO
INFO
MODE
PUSH THE
OK
BUTTON (SEVERAL
TIMES) UNTIL
<
NOFR*>
TEXT
APPEARS ON THE LCD
PUSH THE
UP
/
DOWN
BUTTONS TO ENABLE
1
OR DISABLE
0
THE
FUNCTION
PUSH THE
IP
BUTTON TO EXIT
AND RETURN TO RUN MODE