background image

OPERATIONS (CONT’D)

 

 

 IR TEMP. or TYPE K MAX, MIN, and

 

 RECORD FUNCTIONS

1. Press the 

MAX/MIN 

button to begin capturing 

the Maximum and Minimum values. The REC 

icon will appear in the upper left corner of the 

display.

2. Press the 

MAX/MIN

 button to review the maxi

-

mum and minimum recorded readings.

3. Press and hold the 

MAX/MIN

 button until the dis

-

play returns to standard operation and exits the 

MAX/MIN function. The REC icon in the upper 

left corner of the display will disappear.

 

IR or TYPE K HOLD

1. Press the 

HOLD 

button to freeze IR or type k 

temp. reading in the upper half of the display. 

The HOLD icon will appear in the lower right 

corner of the display.

2. Press the 

HOLD

 button again to return to normal 

operation and HOLD icon will disappear.

 

POWER ON/OFF

 

and AUTO SHUTDOWN

1. Press the power ON/OFF button to turn the me

-

ter ON or OFF.

2. 

Auto Shutdown: 

The meter will automati

-

cally turn off after fifteen minutes if no keys are 

pressed during this time.

3. 

Disable Auto Shutdown: 

To disable auto shut

-

down function, press and hold the IRT button 

as you turn the meter ON. The display will show 

“disAP0”; then release the IRT button.

4. 

Low Battery:

 If the battery indicator appears 

in the upper left corner of the display the unit’s 

battery is low. Follow the directions in the Main

-

tenance section to replace the battery.

MAINTENANCE

REPLACING THE BATTERY

1. The thermometer must be OFF when 

changing the battery. Press        to power 

OFF the thermometer.

2. On the back side of the thermometer, 

locate the        symbol.

3. While holding the thermometer, place 

your thumb on the      .  With gentle pres

-

sure push downward and pull backward; 

the battery cover will begin to open. Use 

your other hand to grasp the cover and 

pull downward. Lift the cover up and off.

4. Lift out the 9-volt battery and disconnect 

it from the connector.

5. Connect a new 9-volt battery and place it 

into the battery cavity.

6. Replace the battery cover by setting it 

over the battery and pushing upward until 

it snaps into place.

7.  Dispose of the old battery according to 

local, state, and federal regulations.

Back sheet 2 of 

2

 

Form No. 546770  Rev B January 15, 2009 

© 2008 SPX

655 Eisenhower Drive

Owatonna, MN 55060

Toll Free: (800) 327-5060

Fax: (866) 287-7222

www.TIF.com

WARRANTY

This product has been produced to provide un

-

limited service. Should it become inoperable after 

the user has performed the recommended main

-

tenance, a no charge repair or replacement will 

be made to the original purchaser. This applies to 

all repairable units that have not been damaged 

or tampered with. The claim must be made within

 

One Year 

of the date of purchase.

Содержание TIF3110

Страница 1: ...icator included with IR function Auto range selection Low battery indicator Auto shutdown FUNCTIONS 1 Laser pointer for IR function 2 Input jack for K type thermocouple 3 Temperature and humidity sensor 4 LCD display 5 Hold button for temp and humidity function 6 Select from air temp wet bulb or dew point readings 7 Hold button for IR or thermocouple input 8 LCD backlight 9 Power ON OFF 10 MAX MIN...

Страница 2: ...1 RH 3 Wet 6 88 140 F 0 1 F C Bulb 21 6 60 C Dew 90 4 140 F 0 1 F C Point 68 60 C SPECIFICATIONS Back sheet 1 of 2008 DISTANCE D TO SPOT SIZE S As the distance D from the object increases the spot size S of the area measured by the unit becomes larger The relationship between distance and spot size is listed on the diagram above The focal point is 914mm 36 The spot sizes indicate 90 encircled ener...

Страница 3: ...era tion mode from air temperature either wet bulb or dew point TEMP WET BULB DEW POINT and RH HOLD 1 Press the HOLD button to freeze air humidity and temperature reading in the upper half of the display The HOLD icon will appear in the upper right corner of the display 2 Press the HOLD button again to return to nor mal operation and HOLD icon will disappear INFRARED THERMOMETER CAUTION To prevent...

Страница 4: ...left corner of the display the unit s battery is low Follow the directions in the Main tenance section to replace the battery MAINTENANCE REPLACING THE BATTERY 1 The thermometer must be OFF when changing the battery Press to power OFF the thermometer 2 On the back side of the thermometer locate the symbol 3 While holding the thermometer place your thumb on the With gentle pres sure push downward a...