Temperature Controller 

for Solar Panels with forced circulation

 

TSol02 

User Manual 

GB

 

K1

K2

K3

K4

T

MAX

MENU

OFF

INTEG.

T

P1

P2

TEMP

TEST

SET

 

1 2 3 4 5 6 7 8 9 10 11 12

13 14 15 16

  

 
Fig. 1:  Exterior Aspect and electrical connections

 

 

 

Code 

Connectors 

Device 

Characteristics 

INP

UT

S

 

T1 

15 

Collector Probe 

Sensor NTC100K@25°C 

Temperature Max: 200°C 

Measurement Range: 0÷190°C   

16 

T2 

13 

Boiler Probe Low Side 

Sensor NTC100K@25°C 

Temperature Range:  0÷99°C 

Measurement Range: 0÷99°C 

14 

T3 

11 

Boiler Probe High Side 

12 

OUT

P

U

T

S

 

P1 

3

 

Solar Pump 

Supply Voltage 230 Vac 

Max  3A 230Vac 

F

ON

 

P2 

 

COM 

Boiler Integration 

Free contacts 

Max  3A 230Vac 

N.C. 

N.O. 

LINE 

Main Supply Voltage 

230 Vac 

10% 50 Hz; 

Fuse T3,15 A 

Mechanical dimensions:  Inbox Controller 3 modules: 120 x 80 x 50 mm 

 

Power Consumption:  2VA 

Applied Norms:  EN 60730-1  50081-1 EN 60730-1 A1 50081-2 

TiEmme elettronica

 Marsciano (PG) Italia 

Tel: +39 075.8743.905  Fax: +39 075.8742239  [email protected] 

 

Mounting and Installation

 must be carried out by trained personnel in compliance with current safety 

and electrical standards.  

 

Place the device in a dry place away from any source of heat 

 

Make sure to position the Probes properly in order to obtain correct temperature readings 

 

Keep sensor and power cables separate. Use free-braided bipolar screened cable min. cross-
section 1.5 mm² and max. Length 25 m. 

 

The connection to the main power must be carried out only after completing the installation

 

 

P1

T1ice

T3-max

T3Sic

T2Sic

T1Sic

ICE

T

P2

INTEG.

A31

A26

A02

A17

A27

A03

P06

t05
t06

t07
t08

A25

T1

P1

P2

T2

T3

P3

Piscina

Pool

P1

T2

T3

T1

T1Pro

A04

Fig. 2 Diagrams of Operation

 

Содержание TSol02

Страница 1: ...PG Italia Tel 39 075 8743 905 Fax 39 075 8742239 info tiemmeelettronica it Montaggio ed Installazione devono essere fatti da personale esperto nel rispetto delle norme vigenti Posizionare il dispositi...

Страница 2: ...re pigiare il tasto K4 Per uscire e memorizzare aspettare circa 5 secondi Tabella 2 Parametri Menu SECONDARIO U M Sigla Min Default Max Set Termostato Sicurezza Collettore T1sic C A02 60 120 180 Termo...

Страница 3: ...2 N Mechanical dimensions Inbox Controller 3 modules 120 x 80 x 50 mm Power Consumption 2VA Applied Norms EN 60730 1 50081 1 EN 60730 1 A1 50081 2 TiEmme elettronica Marsciano PG Italia Tel 39 075 874...

Страница 4: ...n Table 1 MAIN Menu Parameters U M Code Min Default Max Set Differential Thermostat T12 C A31 03 05 30 Boiler Max Thermostat T3max C A26 20 70 99 Integration Thermostat T3min C A25 05 40 90 6 SECONDAR...

Страница 5: ...Hi out of range high temperature over 110 C probe T2 Probe in short circuit 3 Lo out of range low temperature under 0 C probe T3 Probe broken 3 Hi out of range high temperature over 110 C probe T3 Pr...

Страница 6: ...T3 15 A 2 N Dimens es Mec nicas Thermoregulator recessado 3 m dulos 120 x 80 x 50 mm Consumo de Energia 2VA Normas Aplicadas EN 60730 1 50081 1 EN 60730 1 A1 50081 2 TiEmme elettronica Marsciano PG It...

Страница 7: ...Codigo Min Defau lt Max Set Termostato Differencial T12 C A31 03 05 30 Termostato CaldeiMax T3max C A26 20 70 99 Termostato de Integra o T3min C A25 05 40 90 13 Menu SECUNDARIO Os par metros est o lis...

Страница 8: ...2 Hi Fora de alcance causa alta temperatura acima 110 C Sonda T2 Sonda curto circuito 3 Lo Fora de alcance causa baixa temperatura abaixo 0 C Sonda T3 Sonda Interrompida 3 Hi Fora de alcance causa alt...

Отзывы: