![TiEmme SY250 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/tiemme/sy250/sy250_manual_1114519021.webp)
Pag. 21 / 44
DMAN802000066-SY250 Idro 4/8 Buttons Manual
FL42
Maximum air flow for Power 1
0
2000
-
FL43
Maximum air flow for Power 2
0
2000
-
FL44
Maximum air flow for Power 3
0
2000
-
FL45
Maximum air flow for Power 4
0
2000
-
FL46
Maximum air flow for Power 5
0
2000
-
FL47
Maximum air flow for Power 6
0
2000
-
FL50
Maximum air flow for Modulation Power
0
2000
-
3.
FL03 - Combustion Fan Regulation Range
Code
Description
Min
Max
Unit
U22
Minimum speed for Power 1
0
230
[Volt]
300
2800
[RPM]
U23
Minimum speed for Power 2
0
230
[Volt]
300
2800
[RPM]
U24
Minimum speed for Power 3
0
230
[Volt]
300
2800
[RPM]
U25
Minimum speed for Power 4
0
230
[Volt]
300
2800
[RPM]
U26
Minimum speed for Power 5
0
230
[Volt]
300
2800
[RPM]
U27
Minimum speed for Power 6
0
230
[Volt]
300
2800
[RPM]
U30
Minimum speed for Modulation Power
0
230
[Volt]
300
2800
[RPM]
U42
Maximum speed for Power 1
0
230
[Volt]
300
2800
[RPM]
U43
Maximum speed for Power 2
0
230
[Volt]
300
2800
[RPM]
U44
Maximum speed for Power 3
0
230
[Volt]
300
2800
[RPM]
U45
Maximum speed for Power 4
0
230
[Volt]
300
2800
[RPM]
U46
Maximum speed for Power 5
0
230
[Volt]
300
2800
[RPM]
U47
Maximum speed for Power 6
0
230
[Volt]
300
2800
[RPM]
U50
Maximum speed for Modulation Power
0
230
[Volt]
300
2800
[RPM]
U60
Regulation Step
5
100
[Volt]
10
500
[RPM]
4.
FL04 - Auger Regulation Range
Code
Description
Min
Max
Unit
C22
Minimum work time for Power 1
0
60
[s]
C23
Minimum work time for Power 2
0
60
[s]
C24
Minimum work time for Power 3
0
60
[s]
C25
Minimum work time for Power 4
0
60
[s]
C26
Minimum work time for Power 5
0
60
[s]
C27
Minimum work time for Power 6
0
60
[s]
C30
Minimum work time for Modulation Power
0
60
[s]
C42
Maximum work time for Power 1
0
60
[s]
C43
Maximum work time for Power 2
0
60
[s]
C44
Maximum work time for Power 3
0
60
[s]
C45
Maximum work time for Power 4
0
60
[s]
C46
Maximum work time for Power 5
0
60
[s]
C47
Maximum work time for Power 6
0
60
[s]
C50
Maximum work time for Modulation Power
0
60
[s]
C60
Regulation Step
0,1
20
[s]