Pag. 7 / 9 DMAN63W0000020-2Ways2 Manual - System100 Hydro STD2
Stove Room T.
Room Temperature detected by the board [°C] (visible only if
an input is set as Room Probe)
Buffer T.
Buffer tank Temperature [°C] (visible only if
P26
=2, 3, 4)
Pressure
Water Pressure [mbar]
Air Flow
Air Flow [cm/s]
Fan
Combustion Fan speed [RPM] (visible only if
P25
=1, 2)
Auger
Auger working time [s] (visible only if
P81
=0)
Recipe
Current combustion recipe [nr] (visible only if
P04
>1)
Product Code
Product Code: 537
FSYSI01000060.0.0 Control board firmware code and version
FSYSC02000032.0.0 Remote Control firmware code and version
Manual Load
The procedure activates the pellet manual loading with activation in continuous
modality of the Auger motor. The loading stops automatically after 600 seconds. The
system must be OFF for the function can be activated
Cleaning Reset
Menu to reset the ‘System Maintenance 2’ function. It is visible only if
T67
>0.
Settings
Thermostat Management
Menu to set the Radio Room thermostat functioning.
Thermostat Status
Description
Enabled
The Radio Room Thermostat is used by the system
Disabled
The system uses the thermostats of the control panel and, on
the main frame of the display, the value and the image of the
thermostat will disappear.
Radio Standby
Menu to completely switch off the remote control and lower the battery consumption
Description
Display
Push the SET button to enable the Standby mode. To
turn on the radio again, first push the
key and then
the
button twice.
If the function is activated, the system uses the room
probe connected to the control board.
This feature is to be used in case of prolonged non-use
of the radio terminal.
Time and Date
Menu to set time and date.
Description
Keys
Display
Select hours, minutes, year, month and day
Enter editing
SET
Modify the value
Save
SET
Exit
ESC
Radio Test
This Menu is used to test the connection between the radio terminal and the control
board, thereby verifying the level of the electromagnetic pollution. The Terminal
Radio enters in continuous transmission and counts the correct and failed answers.
The quality of the signal depends on the number of the errors.
Change Code
Code changing allows matching the remote control with a specific board, so that a
remote control is matched only with a specific stove or boiler (thus permitting the
coexistence of different systems in the same area). In order to change the code:
select a code
enter the Learn Menu of the control board and push the set key
push the SET button on the terminal radio and verify the result of the
operation
Contrast Setting
This Menu allows setting the display contrast
Description
Keys
Display
Modify the value
Set Contrast
+
15
-
Time and Date
16:45
Thursday
07/02/2016
Standby
Radio
Enable
_____